Improving Safety of Lead Extraction Procedures by Traction Force Sensing

Primary Purpose

Cardiac Implantable Electronic Device Infection, Cardiovascular Infections

Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Force gauge
Sponsored by
Mayo Clinic
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional other trial for Cardiac Implantable Electronic Device Infection focused on measuring infection, pacemaker, ICD, CRT

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion criteria:

• Patients with CIED infection requiring extraction

Exclusion criteria:

  • Age <18 years
  • Noninfectious reasons for extraction
  • Patients with cognitive impairment, who are unable to consent.

Sites / Locations

  • Mayo Clinic in Rochester

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

No Intervention

Arm Label

Intervention

Control

Arm Description

Use of bidirectional rail (superior and inferior approaches) and force sensing using a force gauge to optimize Force application to less than 8 lbs during the extraction procedure.

Conventional lead extraction procedures using a superior approach is performed by experienced operators. Although force information is available the operators are blinded to the information. Inferior rail is left to the discretion of the operator.

Outcomes

Primary Outcome Measures

Fluoroscopic lead displacement
The primary objective of the study is to evaluate the effect of traction force as measured by a digital force gauge on fluoroscopic lead displacement during lead extraction procedures. The investigators hypothesize that the lead displacement on fluoroscopy will be less than 1 cm when the traction force is limited to less than 8 lb.

Secondary Outcome Measures

Full Information

First Posted
January 9, 2019
Last Updated
June 21, 2022
Sponsor
Mayo Clinic
search

1. Study Identification

Unique Protocol Identification Number
NCT03842124
Brief Title
Improving Safety of Lead Extraction Procedures by Traction Force Sensing
Official Title
Improving Safety of Lead Extraction Procedures by Traction Force Sensing
Study Type
Interventional

2. Study Status

Record Verification Date
June 2022
Overall Recruitment Status
Completed
Study Start Date
December 20, 2018 (Actual)
Primary Completion Date
December 10, 2020 (Actual)
Study Completion Date
December 10, 2020 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Mayo Clinic

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
Death and vascular tears occur in up to 1% of the patients undergoing lead extraction procedures. These complications are due to abnormal force vectors during the procedure. The investigators postulate that use of bidirectional traction (superior and inferior directions) and feedback from a digital force gauge is associated with minimal lead displacement compared to conventional lead extraction. Lead displacement is an indirect risk factor for potentially fatal lead extraction complications
Detailed Description
Use of force no greater than 8 pounds of tension will improve lead extraction and minimize lead displacement compared to current standard of care methods which do not limit the force applied. Among subjects undergoing lead extraction procedures for CIED infection, bidirectional rail (superior and inferior) and traction force objective feedback using Force gauge is associated with minimal displacement (<1cm) of the leads (surrogate marker) on fluoroscopy compared to conventional lead extraction. • The research nature of the protocol is explicitly explained to the patient and an informed consent is explained obtained from the patient prior to the procedure. Only patients with CIED infections requiring lead extraction are enrolled in the study. Patients are risk stratified based on our current risk stratifications scheme. Multiple superior and inferior venous accesses are obtained during the procedure. The leads are prepared using locking stylets. Baseline fluoroscopic image of the position of the leads is stored. A deflectable sheath and traction forceps are deployed from the groin to provide downward rail in the force feedback arm. Locking stylet from the lead is in turn attached to a Force gauge (McMaster-Carr Santa Fe Springs, CA). The procedure is performed using continuous fluoroscopic image save tool during the procedure for post procedural viewing and analysis. The patients are randomized to the active arm (to keep force around 8 lb) or the control arm (tactile force discretion based on the operator. The investigator is blinded to the force gauge reading for half of the patients enrolled in the study. For the other half of the patients, the operator optimizes the force to prevent overexertion (<8-9 pounds). Three point along the lead course evaluated during the study. Position of downward turn of the lead in the SVC, heel of the lead (only in case of RV lead) and the lead tip positions are evaluated. The investigators postulate that there will be at least 5 cine-fluoroscopic views per every lead. The investigators hypothesize that use of bidirectional rail and force feedback is associated with minimal displacement of the lead on fluoroscopy.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Cardiac Implantable Electronic Device Infection, Cardiovascular Infections
Keywords
infection, pacemaker, ICD, CRT

7. Study Design

Primary Purpose
Other
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Outcomes Assessor
Masking Description
The study is randomized such that the same operator can be doing the extraction with force gauge with or without the force information.
Allocation
Randomized
Enrollment
22 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Intervention
Arm Type
Active Comparator
Arm Description
Use of bidirectional rail (superior and inferior approaches) and force sensing using a force gauge to optimize Force application to less than 8 lbs during the extraction procedure.
Arm Title
Control
Arm Type
No Intervention
Arm Description
Conventional lead extraction procedures using a superior approach is performed by experienced operators. Although force information is available the operators are blinded to the information. Inferior rail is left to the discretion of the operator.
Intervention Type
Other
Intervention Name(s)
Force gauge
Intervention Description
The investigators postulate that use of bidirectional traction (superior and inferior directions) and feedback from a digital force gauge is associated with minimal lead displacement compared to conventional lead extraction.
Primary Outcome Measure Information:
Title
Fluoroscopic lead displacement
Description
The primary objective of the study is to evaluate the effect of traction force as measured by a digital force gauge on fluoroscopic lead displacement during lead extraction procedures. The investigators hypothesize that the lead displacement on fluoroscopy will be less than 1 cm when the traction force is limited to less than 8 lb.
Time Frame
Intra-procedure measurements

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion criteria: • Patients with CIED infection requiring extraction Exclusion criteria: Age <18 years Noninfectious reasons for extraction Patients with cognitive impairment, who are unable to consent.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Siva K Mulpuru, MD
Organizational Affiliation
Mayo Clinic
Official's Role
Principal Investigator
Facility Information:
Facility Name
Mayo Clinic in Rochester
City
Rochester
State/Province
Minnesota
ZIP/Postal Code
55905
Country
United States

12. IPD Sharing Statement

Links:
URL
https://www.mayo.edu/research/clinical-trials
Description
Mayo Clinic Clinical Trials

Learn more about this trial

Improving Safety of Lead Extraction Procedures by Traction Force Sensing

We'll reach out to this number within 24 hrs