Airway Segmented Stent Modified With 3D Printing for Malignant Stricture Involving Carina and Distal Bronchi
Primary Purpose
Stricture; Trachea, Malignant Neoplasm
Status
Unknown status
Phase
Not Applicable
Locations
China
Study Type
Interventional
Intervention
Airway stent implantation
Sponsored by
About this trial
This is an interventional treatment trial for Stricture; Trachea focused on measuring 3D printed, airway stent, carina, distal bronchi
Eligibility Criteria
Inclusion Criteria:
- Patients with malignant stricture involving carina and bronchi distal to carina based on the diagnosis by bronchoscopy or CT.
Exclusion Criteria:
- Severe infection
- Coagulation disorders
Sites / Locations
- Ruijin Hospital Luwan BranchRecruiting
- Shanghai Tongren HospitalRecruiting
Arms of the Study
Arm 1
Arm Type
Experimental
Arm Label
Airway Stent for Malignant Stricture
Arm Description
Patients with malignant stricture were implanted with covered metallic segmented stent modified with 3D printing.
Outcomes
Primary Outcome Measures
Improvement in Dyspnea using Hugh-Jones classication as criteria
Hugh-Jones classication: dyspnea scale that includes 5 categories.
Stent patency time
Stent patency time is defined as the time from the stent implantation to stent restenosis or death due to any cause, or censored at date last known alive.
Overall survival
OS is defined as the time from the stent implantation to death due to any cause, or censored at date last known alive.
Secondary Outcome Measures
Number of participants with adverse events that are related to stent implantation
Adverse events as follows: migration of the stent, severe chest pain, hemoptysis, granuloma formation, pneumonia and accumulation of secretion
Full Information
NCT ID
NCT03890575
First Posted
March 19, 2019
Last Updated
February 7, 2020
Sponsor
Ruijin Hospital
Collaborators
Shanghai Pulmonary Hospital, Shanghai, China, Shanghai Tong Ren Hospital, Ruijin Hospital Luwan Branch
1. Study Identification
Unique Protocol Identification Number
NCT03890575
Brief Title
Airway Segmented Stent Modified With 3D Printing for Malignant Stricture Involving Carina and Distal Bronchi
Official Title
Covered Metallic Segmented Airway Stent Modified With 3D Printing for Malignant Stricture Involving Carina and Bronchi Distal to Carina: A Multicenter Study
Study Type
Interventional
2. Study Status
Record Verification Date
February 2020
Overall Recruitment Status
Unknown status
Study Start Date
April 1, 2017 (Actual)
Primary Completion Date
November 1, 2022 (Anticipated)
Study Completion Date
December 31, 2022 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Ruijin Hospital
Collaborators
Shanghai Pulmonary Hospital, Shanghai, China, Shanghai Tong Ren Hospital, Ruijin Hospital Luwan Branch
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No
5. Study Description
Brief Summary
In this study, we used the covered metallic segmented airway stent to treat malignant strictures involving carina and bronchi distal to carina and aimed to determine the feasibility, efficacy and safety of this technique.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Stricture; Trachea, Malignant Neoplasm
Keywords
3D printed, airway stent, carina, distal bronchi
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
100 (Anticipated)
8. Arms, Groups, and Interventions
Arm Title
Airway Stent for Malignant Stricture
Arm Type
Experimental
Arm Description
Patients with malignant stricture were implanted with covered metallic segmented stent modified with 3D printing.
Intervention Type
Procedure
Intervention Name(s)
Airway stent implantation
Intervention Description
The airway stents modified with 3D printing were implanted to treat malignant stricture involving carina and bronchi distal to carina.
Primary Outcome Measure Information:
Title
Improvement in Dyspnea using Hugh-Jones classication as criteria
Description
Hugh-Jones classication: dyspnea scale that includes 5 categories.
Time Frame
3 days
Title
Stent patency time
Description
Stent patency time is defined as the time from the stent implantation to stent restenosis or death due to any cause, or censored at date last known alive.
Time Frame
2 months
Title
Overall survival
Description
OS is defined as the time from the stent implantation to death due to any cause, or censored at date last known alive.
Time Frame
6 months
Secondary Outcome Measure Information:
Title
Number of participants with adverse events that are related to stent implantation
Description
Adverse events as follows: migration of the stent, severe chest pain, hemoptysis, granuloma formation, pneumonia and accumulation of secretion
Time Frame
2 months
10. Eligibility
Sex
All
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Patients with malignant stricture involving carina and bronchi distal to carina based on the diagnosis by bronchoscopy or CT.
Exclusion Criteria:
Severe infection
Coagulation disorders
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Zhongmin Wang, MD
Phone
0086-13901848333
Email
wzm0722@hotmail.com
First Name & Middle Initial & Last Name or Official Title & Degree
Qungang Shan, MD
Phone
0086-15989037568
Email
qungangshan@sjtu.edu.cn
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Zhongmin Wang, MD
Organizational Affiliation
Ruijin Hospital
Official's Role
Principal Investigator
Facility Information:
Facility Name
Ruijin Hospital Luwan Branch
City
Shanghai
Country
China
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Ju Gong
Facility Name
Shanghai Tongren Hospital
City
Shanghai
Country
China
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Aiwu Mao
12. IPD Sharing Statement
Plan to Share IPD
No
Learn more about this trial
Airway Segmented Stent Modified With 3D Printing for Malignant Stricture Involving Carina and Distal Bronchi
We'll reach out to this number within 24 hrs