search
Back to results

High Level Pulsed Heat Versus Low Level Steady Heat in Subjects With Chronic Low Back Pain

Primary Purpose

Chronic Pain, Low Back Pain, Heat

Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
High Level Pulsed Heat delivered by Generation 5 devices from Soovu Labs Inc.
Low Level (37 degrees C) delivered by the control device Generation 5 devices from Soovu Labs Inc.
Sponsored by
Soovu Labs Inc.
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Chronic Pain focused on measuring chronic pain, low back pain, heat, thermal, analgesia

Eligibility Criteria

21 Years - 70 Years (Adult, Older Adult)All SexesAccepts Healthy Volunteers

Inclusion Criteria:

  1. Chronic low back pain. By definition chronic low back pain is a condition that has been present for at least 6 months on more days than not. If there is a radiating component of the low back pain the radiating component must have a pain rating less than the non-radiating component of the low back pain.
  2. Subjects must have pretreatment level of pain 4 or greater.
  3. Ages 22 through 70 inclusive
  4. Non pain medications are permitted as needed for conditions such as hypertension, diabetes, heart disease etc.
  5. Medications such as tramadol, codeine, NSIADs, gabapentin and acetaminophen are not permitted during the trial but may be included under the discretion of the study physician.
  6. Subjects must have a reliable method for clinic contact and follow-up.

    -

Exclusion Criteria:

  1. Sciatica or radicular pain without non-radiating low back pain, cancer, radicular pain greater than the non-radiating component of low back pain, pregnancy, skin lesions such as open skin or sores, scar tissue, skins grafts, old burns over the treatment area.
  2. Medications including oxycodone, hydromorphone, hydrocodone, fentanyl and methadone are excluded from the trial but may be included under the discretion of the study physician. Such decisions will be documented should they occur.

    -

Sites / Locations

  • Northern California Research Institute

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

Placebo Comparator

Arm Label

High level pulsed heat

Low level steady heat

Arm Description

Subjects randomized to this arm received a generation 5 device (Soovu Labs Inc.) that produced 30 minutes of heat. The heat was delivered as waves peaking at 45° C.

Subjects randomized to this arm received an identical generation 5 device (Soovu Labs Inc.) that produced 30 minutes of heat. The heat was delivered in a steady manner at 37° C.

Outcomes

Primary Outcome Measures

Pain Rating
Numerical Pain Score (NPS) Range Zero (minimum) through ten (maximum score) thirty minutes after completion of the treatment session.

Secondary Outcome Measures

Full Information

First Posted
September 26, 2019
Last Updated
December 6, 2019
Sponsor
Soovu Labs Inc.
Collaborators
Northern California Research Corporation, University of Washington
search

1. Study Identification

Unique Protocol Identification Number
NCT04109703
Brief Title
High Level Pulsed Heat Versus Low Level Steady Heat in Subjects With Chronic Low Back Pain
Official Title
High Level Pulsed Heat Versus Low Level Steady Heat in Subjects With Chronic Low Back Pain
Study Type
Interventional

2. Study Status

Record Verification Date
November 2019
Overall Recruitment Status
Completed
Study Start Date
June 1, 2019 (Actual)
Primary Completion Date
September 1, 2019 (Actual)
Study Completion Date
September 25, 2019 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Soovu Labs Inc.
Collaborators
Northern California Research Corporation, University of Washington

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
Yes

5. Study Description

Brief Summary
This study is a double blinded randomized active placebo controlled trial in subjects with chronic low back pain. The trial compares pain relief by a device that delivered high level pulsed heat (45 °C) to pain relief delivered by a steady heat lower temperature device (37 °C). The hypothesis is that the high temperature pulsed heat device will produce significantly better pain relief as compared to the lower level steady heat device. The secondary hypothesis is that pain relief will occur faster in the high pulsed heat device as compared to the control device.
Detailed Description
This study will be conducted under Good Clinical Practice (GCP) guidelines and suitable for FDA submission in order to obtain claims such as, "provides temporary pain relief for people with chronic lower back pain." The study is designed as a randomized double blinded two arm placebo controlled trial. The active arm (N=50) receives two active Series 5 heating units (Soovu Labs Inc.) that pulse heat to 45ºC (113ºF). The active Series 5 placebo arm (N=50) gets two identical appearing units (Soovu Labs Inc.) that produce low level of heat at 37ºC (96.8 ºF). For reference skin temperature is about 33 ºC and room temperature 23 ºC. The study hypothesis is that in subjects with chronic low back pain, the active heating device group will show a statistical improvement in pain scores as compared to the active placebo group as measured by the primary outcome measure, the Numeric Pain Scale (NPS). Subjects will be told the study is examining the pain relieving effectiveness of two different levels of heat. Subjects must have chronic low back pain with a pretreatment level of pain 4 or greater on a 0-10 point scale. By definition chronic low back pain is a condition that has been present for at least 6 months and must be present more days than not over the course of a week. No use of pain medications during the four hour trial. However, pain medications including schedule IIIs can be taken up to 30 minutes before the start of the trial. Medications permitted during the trial include medications such as tramadol, codeine, NSIADs, gabapentin and acetaminophen. Non-pain medications for medical indications are permitted at any time. Subjects taking schedule II opioids are excluded from the study. Schedule II opioids include oxycodone, hydromorphone, hydrocodone, fentanyl and methadone. Ages 22 through 70 inclusive. Exclusion criteria- sciatica if present must be rated significantly less than the non -radiating component of the low back pain, pregnancy, skin lesions such as open skin or sores, scar tissue, skins grafts, old burns over the treatment area or neuropathic sensory loss over the treatment site. Pre-treatment assessments include, Numeric Pain Scale, and a pre-study questionnaire (history, treatment preferences, short form Brief Pain Inventory, and short form Magill). Each treatment session lasts approximately 30 minutes with pain assessments throughout using NPS (primary outcome measure). Secondary outcome measures include measures of comfort and willingness to endorse their treatment. All subjects are followed for a 4 hour post treatment period with intermittent pain assessments (NPS). At the end of the post treatment period, subjects complete a post study usability questionnaire and a blinding questionnaire.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Chronic Pain, Low Back Pain, Heat, Analgesia
Keywords
chronic pain, low back pain, heat, thermal, analgesia

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Model Description
Double blinded, randomized, active placebo controlled trial
Masking
ParticipantCare ProviderInvestigatorOutcomes Assessor
Masking Description
Double blinded with a control condition using a low level heating (37 degree C) device. The active experimental device used heast that intermittently pulsed to 45 degrees C.
Allocation
Randomized
Enrollment
100 (Actual)

8. Arms, Groups, and Interventions

Arm Title
High level pulsed heat
Arm Type
Active Comparator
Arm Description
Subjects randomized to this arm received a generation 5 device (Soovu Labs Inc.) that produced 30 minutes of heat. The heat was delivered as waves peaking at 45° C.
Arm Title
Low level steady heat
Arm Type
Placebo Comparator
Arm Description
Subjects randomized to this arm received an identical generation 5 device (Soovu Labs Inc.) that produced 30 minutes of heat. The heat was delivered in a steady manner at 37° C.
Intervention Type
Device
Intervention Name(s)
High Level Pulsed Heat delivered by Generation 5 devices from Soovu Labs Inc.
Other Intervention Name(s)
Experimental arm
Intervention Description
The Soovu Labss Inc. battery powered device is a one inch diameter heating pod that attaches to the user via a ring system. The device may be programmed to deliver a wide variety of treatment algorithms. Control of the devices are through a phone-based bluetooth connection. For this study the treatment algorithm used for subjects in this arm (experimental) used a temperature that was ramped from skin temperature to a peak temperature of 45° C and cycled for 30 minutes.
Intervention Type
Device
Intervention Name(s)
Low Level (37 degrees C) delivered by the control device Generation 5 devices from Soovu Labs Inc.
Other Intervention Name(s)
Control arm
Intervention Description
The Soovu Labs Inc. battery powered device is a one inch diameter heating pod that attaches to the user via a ring system. The device may be programmed to deliver a wide variety of treatment algorithms. Control of the devices are via a phone-based bluetooth connection. For this control arm of the study the treatment algorithm held a steady temperature of 37 degrees C for a 30 minute period.
Primary Outcome Measure Information:
Title
Pain Rating
Description
Numerical Pain Score (NPS) Range Zero (minimum) through ten (maximum score) thirty minutes after completion of the treatment session.
Time Frame
Changes in the Numerical Pain Scale will be compared between baseline and 30 minutes after minutes of treatment.
Other Pre-specified Outcome Measures:
Title
Pain Relief 30 Minutes After the Intervention
Description
Numerical Pain Scale Range Zero (minimum) through ten (maximum score) In this study a lower number on the Numeric Pain Scale means the subject(s) has less pain. Less pain particularly in the experimental group is a better outcome.
Time Frame
Changes in the Numerical Pain Scale will be compared between baseline and thirty minutes post intervention.

10. Eligibility

Sex
All
Gender Based
Yes
Gender Eligibility Description
any gender eligible
Minimum Age & Unit of Time
21 Years
Maximum Age & Unit of Time
70 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria: Chronic low back pain. By definition chronic low back pain is a condition that has been present for at least 6 months on more days than not. If there is a radiating component of the low back pain the radiating component must have a pain rating less than the non-radiating component of the low back pain. Subjects must have pretreatment level of pain 4 or greater. Ages 22 through 70 inclusive Non pain medications are permitted as needed for conditions such as hypertension, diabetes, heart disease etc. Medications such as tramadol, codeine, NSIADs, gabapentin and acetaminophen are not permitted during the trial but may be included under the discretion of the study physician. Subjects must have a reliable method for clinic contact and follow-up. - Exclusion Criteria: Sciatica or radicular pain without non-radiating low back pain, cancer, radicular pain greater than the non-radiating component of low back pain, pregnancy, skin lesions such as open skin or sores, scar tissue, skins grafts, old burns over the treatment area. Medications including oxycodone, hydromorphone, hydrocodone, fentanyl and methadone are excluded from the trial but may be included under the discretion of the study physician. Such decisions will be documented should they occur. -
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
charles chabal, MD
Organizational Affiliation
Soovu Labs Inc.
Official's Role
Principal Investigator
Facility Information:
Facility Name
Northern California Research Institute
City
Sacramento
State/Province
California
ZIP/Postal Code
95821
Country
United States

12. IPD Sharing Statement

Plan to Share IPD
No

Learn more about this trial

High Level Pulsed Heat Versus Low Level Steady Heat in Subjects With Chronic Low Back Pain