Comparative Evaluation of Various Patient Centered Outcomes Following Gingival Depigmentation Using Diode LASER in Different Modes: A Randomized Clinical Trial (LASER)
Pain, Postoperative, Healing Surgical Wounds, Analgesia
About this trial
This is an interventional treatment trial for Pain, Postoperative
Eligibility Criteria
Inclusion Criteria:
- Presence of melanin hyper pigmentation of the anterior labial gingival segment
- Systemically healthy patients who desires correction of gingival pigmentation
- Patients with healthy periodontium
- Patients in age group of 18-45 years old
Exclusion Criteria:
- Presence of uncontrolled systemic diseases example uncontrolled Diabetes, Hypertension etc.
- Pregnant and lactating women
- Gingival enlargement
- Patients who are on Non-steroidal Anti-inflammatory Drugs (NSAID's) or who have taken antibiotics for last 6 months
- Patients who are on drugs that could possibly affect gingival status like phenytoin
- Patients who have undergone any form of oral surgery in last 6 months
- Asthma patients
Sites / Locations
- Krishnadevaraya college of dental sciences
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm 4
Experimental
Experimental
Experimental
Experimental
Group 300µm in continous contact mode
Group 300µm in pulsed contact mode
Group 400µm in continous contact mode
Group 400µm in pulsed contact mode
Diode LASER (A.R.C Fox , Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®[ 2% lignocaine in 1:80000 adrenaline.LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes , 300 µm fibre length will be used in continuous contact mode at a power setting of 1.5 to 3 W. • Simultaneously, increase in temperature on site will be recorded using FLUKETM 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain. Post operative instructions will be given.
Diode LASER (A.R.C Fox, Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®[ 2% lignocaine in 1:80000 adrenaline].LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes, 300 µm fibre length will be used in pulsed contact mode at a power setting of 1.5 - 3 W. Simultaneously, increase in temperature on site will be recorded using FLUKETM 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain. Post operative instructions will be given.
Diode LASER (A.R.C Fox , Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®[ 2% lignocaine in 1:80000 adrenaline.LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes , 400 µm fibre length will be used in continuous contact mode at a power setting of 1.5 - 3 W. • Simultaneously, increase in temperature on site will be recorded using FLUKETM 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain. Post operative instructions will be given.
Diode LASER (A.R.C Fox , Germany, UK) with wavelength of 810nm is selected for the procedure. Before applying the LASER, operating staff and the patient will wear special LASER protective eye glasses. Local infiltration is administered with Lignox®[ 2% lignocaine in 1:80000 adrenaline.LASER tip will be used in contact mode on pigmented gingiva in short light paint brush strokes , 400 µm fibre length will be used in pulsed contact mode at a power setting of 1.5 t 3 W. • Simultaneously, increase in temperature on site will be recorded using FLUKETM 59 Mini (IR) infrared thermometer in non contact mode. Water spray will be used to keep the area moist. Same procedure will be repeated till no pigments remain. Post operative instructions will be given.