Clinical Utility of Handheld Hydrogen Breathalyzer in Identification of Food Sensitivities (AIRE Study) (AIRE)
Primary Purpose
SIBO, Small Bowel Bacterial Overgrowth Syndrome
Status
Active
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Hydrogen content recording
Sponsored by
About this trial
This is an interventional diagnostic trial for SIBO focused on measuring SIBO
Eligibility Criteria
Inclusion Criteria:
- Adults (18 years of age or older)
- Chronic (>3 months) GI symptoms such as nausea, bloating, distention, altered bowel movements, weight loss or abdominal pain with no structural cause other than scleroderma.
- Clinical diagnosis of SIBO by patient's gastroenterologist with plans to obtain a lactulose hydrogen breath test.
- Ability to tolerate oral intake.
- Ability to undergo the LHBT.
- Access to a smartphone with Bluetooth capability
Exclusion Criteria:
- History of current or recent antibiotic use within the last 30 days
- History of inflammatory bowel disease
- Currently following a restrictive diet (for example low Fermentable Oligo-, Di-, Mono-saccharides And Polyols (FODMAP) diet)
- Unable to tolerate oral intake
Sites / Locations
- Johns Hopkins Bayview Medical Center
Arms of the Study
Arm 1
Arm Type
Experimental
Arm Label
Breath analyzer
Arm Description
Candidates who, after the screening period are eligible to receive the AIRE device.
Outcomes
Primary Outcome Measures
Hydrogen content in parts per million (ppm)
Exhaled hydrogen (H2) content as measured over a 1-week period by AIRE on the patient's usual diet at home and the results of the standardized lactulose hydrogen breath test (LHBT) performed in the clinic. Baseline hydrogen content is measured with AIRE device (study intervention) and LHBT (standard of care). Only test with AIRE will be reported.
Hydrogen content in parts per million (ppm)
For participants who have a positive LHBT test at baseline, antibiotics are prescribed as part of standard of care. These participants will have a repeat AIRE test at 2 weeks post antibiotic treatment.
Hydrogen content in parts per million (ppm)
For participants who have a negative LHBT test at baseline, a repeat AIRE test is done at 1 month after baseline test.
Secondary Outcome Measures
Full Information
NCT ID
NCT04309396
First Posted
March 12, 2020
Last Updated
March 13, 2023
Sponsor
Johns Hopkins University
Collaborators
FoodMarble
1. Study Identification
Unique Protocol Identification Number
NCT04309396
Brief Title
Clinical Utility of Handheld Hydrogen Breathalyzer in Identification of Food Sensitivities (AIRE Study)
Acronym
AIRE
Official Title
Clinical Utility of Handheld Hydrogen Breathalyzer in Identification of Non-immune Mediated Food Sensitivities (AIRE Study)
Study Type
Interventional
2. Study Status
Record Verification Date
March 2023
Overall Recruitment Status
Active, not recruiting
Study Start Date
October 1, 2020 (Actual)
Primary Completion Date
October 30, 2024 (Anticipated)
Study Completion Date
October 30, 2024 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Johns Hopkins University
Collaborators
FoodMarble
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Device Product Not Approved or Cleared by U.S. FDA
Yes
5. Study Description
Brief Summary
Small intestinal bacterial overgrowth (SIBO) is defined as a condition in which an abnormally high amount of coliform bacteria is present in the small bowel and results in premature anaerobic fermentation of carbohydrates before reaching the colon. Commonly recognized causes include gastric achlorhydria, post-surgical bowel stasis, gastrocolic/coloenteric fistulas, and motility disorders leading to bowel stasis.. The current "gold standard" for the diagnosis of SIBO, is a breath test that measures the concentration of hydrogen in response to lactulose, a carbohydrate that is only metabolized by bacteria. However, its accuracy is only about 50% and therefore it is not a very useful test, leading most physicians to treat these patients empirically based on clinical suspicion alone. The purpose of this study is to evaluate the clinical utility of a portable medical device called AIRE, an over-the-counter, commercially available handheld breath analyzer that measures exhaled hydrogen content.
Detailed Description
Small intestinal bacterial overgrowth (SIBO) is defined as a condition in which an abnormally high amount of coliform bacteria is present in the small bowel and results in premature anaerobic fermentation of carbohydrates before reaching the colon. Commonly recognized causes include gastric achlorhydria (i.e. due to longstanding proton pump inhibitor (PPI) use), post-surgical bowel stasis, and gastrointestinal motility disorders leading to bowel stasis. Although SIBO is commonly suspected, a major limitation in the field is the lack of a highly accurate test for SIBO. The current gold standard relies on the demonstration of an early rise in breath hydrogen concentration in response to an orally ingested carbohydrate (commonly, lactulose) but its accuracy is about 50%. This may be because it is a one-time snapshot with an artificial substrate. Further, it has to be performed in a clinic, takes up to 5 hours and is relatively expensive. The purpose of this study is to evaluate the clinical utility of a portable medical device called AIRE, which is a validated and commercially available handheld breathalyzer that measures hydrogen content in the breath and connects via Bluetooth to an associated smartphone application to provide immediate results and visual feedback after use. H2 concentrations determined by the AIRE device showed significant correlation with those measured by LHBT. The AIRE device therefore provides an alternative way to measure exhaled H2 that has the potential for addressing many of the limitations of the standard breath test.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
SIBO, Small Bowel Bacterial Overgrowth Syndrome
Keywords
SIBO
7. Study Design
Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
45 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Breath analyzer
Arm Type
Experimental
Arm Description
Candidates who, after the screening period are eligible to receive the AIRE device.
Intervention Type
Device
Intervention Name(s)
Hydrogen content recording
Intervention Description
Eligible participants will eat participants' normal, typical diets during the first week of the study. Participants will use the AIRE machine to measure exhaled H2 content before and after two meals each day - the first meal of the day and the last meal of the day. Participants will breathe into the AIRE machine before eating to obtain a baseline value. Once participants have finished eating, participants will breathe into the AIRE machine 30 minutes, 60 minutes, and 90 minutes postprandially. The participants will record participants' food intake and symptoms directly into participants' smartphone via an app that comes with the AIRE device.
Primary Outcome Measure Information:
Title
Hydrogen content in parts per million (ppm)
Description
Exhaled hydrogen (H2) content as measured over a 1-week period by AIRE on the patient's usual diet at home and the results of the standardized lactulose hydrogen breath test (LHBT) performed in the clinic. Baseline hydrogen content is measured with AIRE device (study intervention) and LHBT (standard of care). Only test with AIRE will be reported.
Time Frame
Baseline (1 week)
Title
Hydrogen content in parts per million (ppm)
Description
For participants who have a positive LHBT test at baseline, antibiotics are prescribed as part of standard of care. These participants will have a repeat AIRE test at 2 weeks post antibiotic treatment.
Time Frame
At 2 weeks after antibiotic treatment for positive LHBT
Title
Hydrogen content in parts per million (ppm)
Description
For participants who have a negative LHBT test at baseline, a repeat AIRE test is done at 1 month after baseline test.
Time Frame
At one month after negative LHBT
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Adults (18 years of age or older)
Chronic (>3 months) GI symptoms such as nausea, bloating, distention, altered bowel movements, weight loss or abdominal pain with no structural cause other than scleroderma.
Clinical diagnosis of SIBO by patient's gastroenterologist with plans to obtain a lactulose hydrogen breath test.
Ability to tolerate oral intake.
Ability to undergo the LHBT.
Access to a smartphone with Bluetooth capability
Exclusion Criteria:
History of current or recent antibiotic use within the last 30 days
History of inflammatory bowel disease
Currently following a restrictive diet (for example low Fermentable Oligo-, Di-, Mono-saccharides And Polyols (FODMAP) diet)
Unable to tolerate oral intake
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Glenn Treisman, MD
Organizational Affiliation
Johns Hopkins University
Official's Role
Principal Investigator
Facility Information:
Facility Name
Johns Hopkins Bayview Medical Center
City
Baltimore
State/Province
Maryland
ZIP/Postal Code
21224
Country
United States
12. IPD Sharing Statement
Plan to Share IPD
No
Learn more about this trial
Clinical Utility of Handheld Hydrogen Breathalyzer in Identification of Food Sensitivities (AIRE Study)
We'll reach out to this number within 24 hrs