A Randomized RSA Study Comparing HXLPE to Conventional Polyethylene in Cemented Total Hip Arthroplasty

Primary Purpose

Osteoarthritis, Hip, Arthroplasty Complications

Status
Completed
Phase
Not Applicable
Locations
Sweden
Study Type
Interventional
Intervention
Device: Randomization between prosthetic components
Sponsored by
Umeå University
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Osteoarthritis, Hip focused on measuring osteoarthritis, total hip arthroplasty, migration, wear

Eligibility Criteria

50 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Primary osteoarthritis
  • Age 50 years and above
  • Patients who understand the conditions of the study and are willing to participate for the length of the prescribed follow-up

Exclusion Criteria:

  • Rheumatoid Arthritis
  • Grossly abnormal hip anatomy (severe dysplasia)
  • Fracture sequelae
  • Patients who, as judged by the surgeon, are mentally incompetent or are reasonable unlikely to be compliant with the requirements of the study
  • Immune suppression or grave systemic illness

Sites / Locations

  • Lycksele hospital

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Experimental

Arm Label

Acetabular cup HXLPE (Intervention)

Acetabular cup Conventional PE (control)

Arm Description

Randomization to HXLPE acetabular component.

Randomization to Coventional PE as control group

Outcomes

Primary Outcome Measures

Magnitude of Polyethylene Wear
The size of the femoral component penetration into the polyethylene measured in millimeters per year and the volumetric annual wear millimetres with radiostereometric (RSA) analysis of radiographs.

Secondary Outcome Measures

Magnitude of Cup Migration
Migration measured in millimetres per year with radiostereometric (RSA) analysis of radiographs. Radiostereometric analysis (RSA) is a stereo X-ray technique used in clinical research studies to evaluate micro-motion and wear of orthopaedic implants within bone. The method has a high accuracy and precision. Technical requirements include the need for implanted marker beads and radiograph view angles determined by a calibration cage.
Surgical complications
Surgical complications and reapportions during the study period.

Full Information

First Posted
March 24, 2020
Last Updated
March 30, 2020
Sponsor
Umeå University
search

1. Study Identification

Unique Protocol Identification Number
NCT04322799
Brief Title
A Randomized RSA Study Comparing HXLPE to Conventional Polyethylene in Cemented Total Hip Arthroplasty
Official Title
A Randomized Controlled RSA Study Comparing the 2nd Generation Highly Cross-linked Polyethylene to Conventional Polyethylene in Cemented Total Hip Arthroplasty
Study Type
Interventional

2. Study Status

Record Verification Date
March 2020
Overall Recruitment Status
Completed
Study Start Date
February 7, 2013 (Actual)
Primary Completion Date
December 4, 2014 (Actual)
Study Completion Date
June 30, 2019 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Umeå University

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Product Manufactured in and Exported from the U.S.
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
A prospective randomized study comparing two types of cemented acetabular components, a highly-crosslinked polyethylene or conventional polyethylene in total hip arthroplasty. Primary outcome are component wear measured by RSA, secondary outcomes are migration and complications. Patients are evaluated 5 years postoperatively.
Detailed Description
Background: Total hip replacements is a cost effective treatment of a symptomatic degenerative hip disease. Cemented total hip replacements are the most common implants in Sweden (Swedish hip registry, 2009). Wear of ultra high molecular weight polyethylene has been a issue with regard to implant survival. At the time of the shift of the millennium highly cross-linked polyethylene was introduced to the markets. Experimental studies had shown reduction of wear in hip simulator studies (McKellop,1999). Subsequently the intention is to reduce osteolysis and implant loosening. Single surgeon pilot studies in the 1970 (Wroblevski et al. 1996, Oonishi 1998, Grobelaar 1999) were the first clinical series with good results leading to the development of 2nd generation highly cross-linked polyethylenes which is now the almost exclusively used PE worldwide. So far medium term clinical evaluation and laboratory assessment have showed reduced wear and good mechanical properties (Digas et al. 2003, 2004, 2007, Röhrl et al. 2005, 2007, D´Antonio et al. 2005) Production of highly crosslinked polyethylene (HXLPE) consists of several steps. First the PE material is crosslinked by being subjected to either gamma irradiation of various intensity or electron beam irradiation. The second step is to remove the free radicals created during the irradiation. This is done either by annealing (i.e. warming up the PE to just under its melting temperature) or melting (i.e. warming up the PE to above its melting temperature). Finally, the implant is sterilized either by gamma irradiation or Ethylene Oxide and packed in vacuum or inert atmosphere.There are some possible drawbacks and challenges in the process of cross-linking polyethylene with regard to preserving the mechanical properties and elimination of free radicals (Kurtz et al. 2006, Currier et al. 2007). Submelt annealing preserves mechanical properties but on the other hand cannot eliminate all free radicals existing in the PE. Retrieval-studies of some 2nd generation highly cross-linked polyethylenes manufactured in this way have shown signs of oxidation. The in-vivo oxidation has been located in the non articulating area such as the circumference of the acetabular liner. It has been discussed that the femoral head may protect the polyethylene against oxidation, and hence prevent the possible negative consequences of remaining free radicals (Currier et al 2007). Melting the polyethylene eliminates all free radicals but alters the mechanical properties. This has led to PE cracks and implant failure in some clinical studies (Furmanski et al. 2009), whereas it has not been seen in other. Finally, wear particles of highly crosslinked polyethylene are more often in the submicron size compared to conventional PE. Although these particles have a higher biological activity (Fisher et al. 2006), results of recent studies show however, that the overall risk for osteolysis and aggressiveness of highly cross-linked particles is reduced (Galvin et al. 2007). Because of differences in the manufacturing processes of highly crosslinking PE between manufacturers (i.e. different GUR used, type of irradiation, intensity of irradiation, postirradiative treatment, type of sterilization and packing, etc, etc) all highly crosslinked polyethylenes differ somewhat from each other. One can not extrapolate results of in vitro or in vivo wear studies of one manufacturer to another. Also, because of these manufacturing differences, fixation characteristics may differ between the various types of HXLPEs. Therefore it is imperative that all new highly crosslinked polyethylenes are subjected to clinical studies of their wear and fixation performance using high accuracy methods before being used extensively. Methods: A prospective randomized study comparing acetabular components made of HXLPE or conventional PE in total hip arthroplasty. The study will be conducted at Department of Orthopaedics, Umeå University, Umeå, Sweden. Aim of study The aim of the study is to compare the wear and migration of a 2nd generation polyethylene from Link with conventional polyethylene in an all-poly cemented acetabular cup of the Lubinus brand using radiostereometric analysis (RSA) with 5-year follow-up. Hypothesis The H0-hypothesis is that the difference with in wear between HXLPE and conventional PE will not increase up to 5-year follow-up. Material Patients (age 50 years and above) with primary osteoarthritis between 2013 and 2014 at the orthopaedic department at the county hospital (Lycksele) affiliated to Umeå University hospital, Sweden. Patients were treated with a cemented total hip arthroplasty. At surgery, after the acetabulum was reamed, randomization was performed by opening of a consecutively numbered sealed envelope informing whether a cup made of HXLPE or conventional PE should be inserted. The envelopes were kept far away from the operation theatre and were opened by a research nurse contacted by telephone. Randomization was stratified for gender. Within each stratum there was block randomization with 6 permutations in each block. Patients have been followed for 5 years postoperatively. Implants • Acetabular cup Intervention: Link-Ticona GUR 1020 HXLPE, 32 mm inner diameter (Trade name Lubinus® X-LINKed® ) Control: Link-Chirulene GUR 1020 UHMWPE, 32 mm inner diameter (Trade name Lubinus ® UHMWPE) • Femur stem Test and control: Lubinus® SP II®, CrCo femoral head, 32 mm diameter Radio Sterometric Analysis (RSA) Radiostereometric analysis measurements will be performed 5 years postoperatively. Wear will be measured as penetration of the femoral head into the polyethylene in the proximal, proximo-medial (2D pm), proximo-posterior (2D pp), and proximo-medial-posterior (3D) directions. Since the penetration during the initial 3 months represents polyethylene yield or bedding in, wear measurements will be reported from 3 months and up to 5 years postoperatively. Quality of cup fixation will be measured as rotations of the cup around the three cardinal axes in relation to acetabulum with the postoperative examination as reference. The RSA measurements will be analysed at Umeå University Hospital. Patient data will be saved in a specific research database at Umeå University Hospital following specific guidelines from the national data security committee. Ethical approval The study has been approved by the Ethics Committee of Umeå University (Dnr 2011-173-31M, 2018-34-31M). Sample size With a mean difference in wear at 2 years of 0.1 mm or more (SD ± 0.1) between the groups (p< 0.05), 25 patients in each group will give a power of > 80%. In order to cater for losses during the follow up a total of 57 patients will be enrolled. Scientific Value All new materials should be monitored closely and introduced in small study groups using a high precision measurement technique. Many markets require such tests before acceptance for general use is given. The new highly crosslinked polyethylene from Link-Ticona is not equivalent to current highly crosslinked polyethylenes on the market, and one can not extrapolate wear results from these other designs.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Osteoarthritis, Hip, Arthroplasty Complications
Keywords
osteoarthritis, total hip arthroplasty, migration, wear

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Model Description
Randomized controlled trial
Masking
None (Open Label)
Masking Description
Two different acetabular cups in total hip arthroplasty. No difference in surgical surgical technique and type of stem. The cup have the identical outlining.
Allocation
Randomized
Enrollment
57 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Acetabular cup HXLPE (Intervention)
Arm Type
Experimental
Arm Description
Randomization to HXLPE acetabular component.
Arm Title
Acetabular cup Conventional PE (control)
Arm Type
Experimental
Arm Description
Randomization to Coventional PE as control group
Intervention Type
Procedure
Intervention Name(s)
Device: Randomization between prosthetic components
Intervention Description
Patients are randomized between two types of cup components in total hip arthroplasty. Identical cups made of either highly-crosslinked polyethylene or conventional polyethylene.
Primary Outcome Measure Information:
Title
Magnitude of Polyethylene Wear
Description
The size of the femoral component penetration into the polyethylene measured in millimeters per year and the volumetric annual wear millimetres with radiostereometric (RSA) analysis of radiographs.
Time Frame
0-5 years
Secondary Outcome Measure Information:
Title
Magnitude of Cup Migration
Description
Migration measured in millimetres per year with radiostereometric (RSA) analysis of radiographs. Radiostereometric analysis (RSA) is a stereo X-ray technique used in clinical research studies to evaluate micro-motion and wear of orthopaedic implants within bone. The method has a high accuracy and precision. Technical requirements include the need for implanted marker beads and radiograph view angles determined by a calibration cage.
Time Frame
0-5 years
Title
Surgical complications
Description
Surgical complications and reapportions during the study period.
Time Frame
0-5 years

10. Eligibility

Sex
All
Minimum Age & Unit of Time
50 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Primary osteoarthritis Age 50 years and above Patients who understand the conditions of the study and are willing to participate for the length of the prescribed follow-up Exclusion Criteria: Rheumatoid Arthritis Grossly abnormal hip anatomy (severe dysplasia) Fracture sequelae Patients who, as judged by the surgeon, are mentally incompetent or are reasonable unlikely to be compliant with the requirements of the study Immune suppression or grave systemic illness
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Kjell Nilsson, Professor
Organizational Affiliation
Umeå University
Official's Role
Principal Investigator
Facility Information:
Facility Name
Lycksele hospital
City
Lycksele
ZIP/Postal Code
921 37
Country
Sweden

12. IPD Sharing Statement

Plan to Share IPD
Yes
IPD Sharing Plan Description
On request
IPD Sharing Time Frame
Publication at 1 year after completion of the study during 2020.
IPD Sharing Access Criteria
International scientific peer-reviewed journal
Citations:
PubMed Identifier
18236180
Citation
Digas G, Karrholm J, Thanner J, Herberts P. 5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: two randomized studies using radiostereometric analysis. Acta Orthop. 2007 Dec;78(6):746-54. doi: 10.1080/17453670710014518.
Results Reference
background
PubMed Identifier
16330997
Citation
D'Antonio JA, Manley MT, Capello WN, Bierbaum BE, Ramakrishnan R, Naughton M, Sutton K. Five-year experience with Crossfire highly cross-linked polyethylene. Clin Orthop Relat Res. 2005 Dec;441:143-50. doi: 10.1097/00003086-200512000-00024.
Results Reference
background
PubMed Identifier
18534491
Citation
Rajadhyaksha AD, Brotea C, Cheung Y, Kuhn C, Ramakrishnan R, Zelicof SB. Five-year comparative study of highly cross-linked (crossfire) and traditional polyethylene. J Arthroplasty. 2009 Feb;24(2):161-7. doi: 10.1016/j.arth.2007.09.015. Epub 2008 Mar 4.
Results Reference
background
PubMed Identifier
17031310
Citation
Kurtz SM, Hozack WJ, Purtill JJ, Marcolongo M, Kraay MJ, Goldberg VM, Sharkey PF, Parvizi J, Rimnac CM, Edidin AA. 2006 Otto Aufranc Award Paper: significance of in vivo degradation for polyethylene in total hip arthroplasty. Clin Orthop Relat Res. 2006 Dec;453:47-57. doi: 10.1097/01.blo.0000246547.18187.0b.
Results Reference
background
PubMed Identifier
18236179
Citation
Rohrl SM, Li MG, Nilsson KG, Nivbrant B. Very low wear of non-remelted highly cross-linked polyethylene cups: an RSA study lasting up to 6 years. Acta Orthop. 2007 Dec;78(6):739-45. doi: 10.1080/17453670710014509.
Results Reference
background
PubMed Identifier
10221831
Citation
McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res. 1999 Mar;17(2):157-67. doi: 10.1002/jor.1100170203.
Results Reference
background
PubMed Identifier
20144479
Citation
Lerf R, Zurbrugg D, Delfosse D. Use of vitamin E to protect cross-linked UHMWPE from oxidation. Biomaterials. 2010 May;31(13):3643-8. doi: 10.1016/j.biomaterials.2010.01.076. Epub 2010 Feb 9.
Results Reference
background
PubMed Identifier
17823030
Citation
Bragdon CR, Greene ME, Freiberg AA, Harris WH, Malchau H. Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads. J Arthroplasty. 2007 Sep;22(6 Suppl 2):125-9. doi: 10.1016/j.arth.2007.03.009. Epub 2007 Jul 26.
Results Reference
background
PubMed Identifier
31564144
Citation
Skoldenberg OG, Rysinska AD, Chammout G, Salemyr M, Mukka SS, Boden H, Eisler T. A randomized double-blind noninferiority trial, evaluating migration of a cemented vitamin E-stabilized highly crosslinked component compared with a standard polyethylene component in reverse hybrid total hip arthroplasty. Bone Joint J. 2019 Oct;101-B(10):1192-1198. doi: 10.1302/0301-620X.101B10.BJJ-2019-0456.R2.
Results Reference
background
PubMed Identifier
33566703
Citation
Otten V, Wasterlund D, Lindbjorn J, Mertens C, Mukka S, Crnalic S, Nilsson KG. Evaluation of a new cemented highly cross-linked all-polyethylene cup: a prospective and randomised study assessing wear and fixation characteristics using radiostereometric analysis. Hip Int. 2022 Nov;32(6):779-786. doi: 10.1177/1120700021989991. Epub 2021 Feb 10.
Results Reference
derived

Learn more about this trial

A Randomized RSA Study Comparing HXLPE to Conventional Polyethylene in Cemented Total Hip Arthroplasty