search
Back to results

Feasibility of Non-contact Magnetically-controlled Capsule Endoscopy During COVID-19 Pandemic

Primary Purpose

Gastrointestinal Disease, Infectious Disease, Capsule Endoscopy

Status
Completed
Phase
Not Applicable
Locations
China
Study Type
Interventional
Intervention
non-contact magnetically-controlled capsule endoscopy
Sponsored by
Changhai Hospital
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional prevention trial for Gastrointestinal Disease

Eligibility Criteria

18 Years - 80 Years (Adult, Older Adult)All SexesAccepts Healthy Volunteers

Inclusion Criteria:

Signed the informed consents before joining this study

Exclusion Criteria:

(1) dysphagia or symptoms of gastric outlet obstruction, suspected or known intestinal stenosis,overt gastrointestinal bleeding,fistulas and strictures; (2)history of upper gastrointestinal surgery or suspected delayed gastric emptying; (3) Patients with poor general condition,asthma or claus trophobia; (4) Implanted metallic devices such as pacemakers,defibrillators, artificial heart valves or joint prostheses; (5) Pregnancy or mentally ill person; (6) currently participating in another clinical study;(7)communication obstacles persons.

Sites / Locations

  • Changhai Hospital

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

Non-contact MCE examination

MCE examination

Arm Description

After an overnight fasting and drinking 1000 mL water and simethicone for gastric dilatation and preparation, the study subject positions himself (herself) on the examination bed in Room A, while the operating doctor sits in Room B at the remote control workstation instructing her to swallow the capsule via the audio-visual exchange system. After the capsule entering the stomach, the doctor manipulated the two joysticks on the remote control workstation, mobilizing the robotic magnetic arm, and simultaneously driving the precise movement and rotation of the capsule to perform the gastric examination. In order to simplify the examination procedure, the data recorder was put on the examination bed. The patient lay down after swallowing the capsule under the remote guidance of the endoscopist.

After an overnight fasting and drinking 1000 mL water and simethicone for gastric dilatation and preparation, the subjects put on the data recorder with the help of an endoscopist. Then, the endoscopist activated the capsule with the capsule locator. The patient was instructed to assume the supine or left lateral decubitus position and to swallow the capsule with a small amount of water to effectively observe the esophagus and dentate line. Then, under the guidance of the endoscopist face to face, the subject turned over on the bed to complete the examination.

Outcomes

Primary Outcome Measures

Number of Participants With Complete Observation
The number of participants with complete observation. Complete observation of the mucosa means over 90% of the mucosa observed in gastric cardia, fundus, body, angulus, antrum and pylorus.

Secondary Outcome Measures

Maneuverability Score
Maneuverability score was the sum of four subjective scores rated by the operator (signal transmission quality score, operating comfort score, gastric visualization score and study subject compliance score), each of which ranged from 1 to 5 denoting the lowest to the highest degree of satisfaction and the range of total score from 0 to 20. The higher the score, the better the maneuverability.
Gastric Examination Time(GET)
GET was defined as the time taken for the endoscopist to complete the gastric examination to his or her satisfaction
the Comfort and Acceptability of Patients
The investigators use a satisfaction questionnaire to evaluate the comfort and acceptability of each patient by two sub questionnaires, which was pre-procedure patient perception (3 items, ranged from 0 to 12 ) and post-procedure patient satisfaction (12 items, ranged from 0 to 48) .The higher the score, the worse the patient's satisfaction.
The Total Number of Patients Who Who Had a Diagnosis of Positive Findings
It was calculated using the following formula: number of patients with positive findings divided by the total number of patients that underwent examination.

Full Information

First Posted
May 9, 2020
Last Updated
January 3, 2022
Sponsor
Changhai Hospital
search

1. Study Identification

Unique Protocol Identification Number
NCT04389333
Brief Title
Feasibility of Non-contact Magnetically-controlled Capsule Endoscopy During COVID-19 Pandemic
Official Title
Feasibility of Non-contact Magnetically-controlled Capsule Endoscopy During COVID-19 Pandemic: a Prospective, Open-label, Pilot, Randomized Trial
Study Type
Interventional

2. Study Status

Record Verification Date
December 2021
Overall Recruitment Status
Completed
Study Start Date
March 26, 2020 (Actual)
Primary Completion Date
April 26, 2020 (Actual)
Study Completion Date
May 20, 2020 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Changhai Hospital

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
In December 2019, an outbreak of pneumonia associated with a novel coronavirus named as severe acute respiratory syndrome coronavirus 2 (SARSCoV-2) was reported in Wuhan city, China, and spread exponentially throughout China and other countries in the following weeks. It is recommended that elective endoscopies should be deferred during the COVID-19 outbreak for the potential transmission between patients and medical staff in the statements of Asian Pacific Society for Digestive Endoscopy (APSDE-COVID statements). Therefore, exploring an alternative for patients with the requirements of endoscopy during the outbreak is of great importance. Herein,the investigators developed an novel non-contact magnetically-controlled capsule endoscopy (Nc-MCE) system (Figure 1) adds a remote control workstation and a audio-visual exchange system to the original well-established MCE system. This study was a open-label, prospective, randomized controlled study approved by the institutional review board of Shanghai Changhai Hospital. It was designed to evaluate the diagnostic utility, safety, feasibility and patients acceptability of Nc-MCE in patients with an indication of endoscopy, and comparing it with the result of MCE.
Detailed Description
The nc-MCE system added a remote control workstation and an audio-visual exchange system to the original well-establish MCE system.Conventional protective measures could be adopted to endoscopist. Although the endoscopist and the patient are in different rooms, the endoscopist was able to see the patient and communicate with him or her through the audio-visual exchange system all the time. In order to simplify the examination procedure, the data recorder was putted on the examination bed. The patient lay down after swallowing the capsule under the remote guidance of the endoscopist.And the endoscopist of MCE and nc-MCE was the same one with experience of more than 1000 cases of MCCG operation. The investigators recruited 40 patients who have related symptom and healthy people mainly from outpatient clinic or hospital health examination center. After fully understanding the procedure of nc-MCE, patients with informed consent were randomly divided into MCE group and nc-MCE group(1:1) by using a stratified block randomization(block size four). The basic characteristics of the enrolled patients were prospectively collected. The primary endpoint was the maneuverability score evaluated by endoscopist. And the investigators choose the gastric examination time,the comfort and acceptability of patients, diagnostic yield and completeness of gastric examination as the secondary endpoint. The safety endpoint of nc-MCE was evaluated by the occurrence of adverse events.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Gastrointestinal Disease, Infectious Disease, Capsule Endoscopy

7. Study Design

Primary Purpose
Prevention
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Model Description
The investigators recruited 40 patients who have related symptom and healthy people mainly from outpatient clinic or hostipal health examination center. After fully understanding the procedure of nc-MCE,patients with informed consent were randomly divided into MCE group and nc-MCE group(1:1) by using a stratified block randomization(block size four)
Masking
None (Open Label)
Allocation
Randomized
Enrollment
40 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Non-contact MCE examination
Arm Type
Experimental
Arm Description
After an overnight fasting and drinking 1000 mL water and simethicone for gastric dilatation and preparation, the study subject positions himself (herself) on the examination bed in Room A, while the operating doctor sits in Room B at the remote control workstation instructing her to swallow the capsule via the audio-visual exchange system. After the capsule entering the stomach, the doctor manipulated the two joysticks on the remote control workstation, mobilizing the robotic magnetic arm, and simultaneously driving the precise movement and rotation of the capsule to perform the gastric examination. In order to simplify the examination procedure, the data recorder was put on the examination bed. The patient lay down after swallowing the capsule under the remote guidance of the endoscopist.
Arm Title
MCE examination
Arm Type
Active Comparator
Arm Description
After an overnight fasting and drinking 1000 mL water and simethicone for gastric dilatation and preparation, the subjects put on the data recorder with the help of an endoscopist. Then, the endoscopist activated the capsule with the capsule locator. The patient was instructed to assume the supine or left lateral decubitus position and to swallow the capsule with a small amount of water to effectively observe the esophagus and dentate line. Then, under the guidance of the endoscopist face to face, the subject turned over on the bed to complete the examination.
Intervention Type
Device
Intervention Name(s)
non-contact magnetically-controlled capsule endoscopy
Intervention Description
The novel non-contact magnetically-controlled capsule endoscopy (MCE) system (Ankon Technologies, Wuhan, China) (Figure 1) added a remote control workstation and an audio-visual exchange system to the original well-establish MCE system, which consisted of a robotic magnetic arm, a workstation (currently bypassed) and a capsule endoscope.
Primary Outcome Measure Information:
Title
Number of Participants With Complete Observation
Description
The number of participants with complete observation. Complete observation of the mucosa means over 90% of the mucosa observed in gastric cardia, fundus, body, angulus, antrum and pylorus.
Time Frame
During the procedure
Secondary Outcome Measure Information:
Title
Maneuverability Score
Description
Maneuverability score was the sum of four subjective scores rated by the operator (signal transmission quality score, operating comfort score, gastric visualization score and study subject compliance score), each of which ranged from 1 to 5 denoting the lowest to the highest degree of satisfaction and the range of total score from 0 to 20. The higher the score, the better the maneuverability.
Time Frame
During the procedure
Title
Gastric Examination Time(GET)
Description
GET was defined as the time taken for the endoscopist to complete the gastric examination to his or her satisfaction
Time Frame
During the procedure
Title
the Comfort and Acceptability of Patients
Description
The investigators use a satisfaction questionnaire to evaluate the comfort and acceptability of each patient by two sub questionnaires, which was pre-procedure patient perception (3 items, ranged from 0 to 12 ) and post-procedure patient satisfaction (12 items, ranged from 0 to 48) .The higher the score, the worse the patient's satisfaction.
Time Frame
After the procedure(within 5 days)
Title
The Total Number of Patients Who Who Had a Diagnosis of Positive Findings
Description
It was calculated using the following formula: number of patients with positive findings divided by the total number of patients that underwent examination.
Time Frame
after the procedure(within 5 days)
Other Pre-specified Outcome Measures:
Title
Adverse Events
Description
Each patient was followed up for 2 weeks by telephone and hospital information system to confirm capsule excretion and any adverse events (AEs), including COVID-19 infection.
Time Frame
During and within 2 weeks after the procedure

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
80 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria: Signed the informed consents before joining this study Exclusion Criteria: (1) dysphagia or symptoms of gastric outlet obstruction, suspected or known intestinal stenosis,overt gastrointestinal bleeding,fistulas and strictures; (2)history of upper gastrointestinal surgery or suspected delayed gastric emptying; (3) Patients with poor general condition,asthma or claus trophobia; (4) Implanted metallic devices such as pacemakers,defibrillators, artificial heart valves or joint prostheses; (5) Pregnancy or mentally ill person; (6) currently participating in another clinical study;(7)communication obstacles persons.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Zhuan Liao, MD
Organizational Affiliation
Department of Gastroenterology, Changhai Hospital, the Naval Medical University
Official's Role
Study Chair
Facility Information:
Facility Name
Changhai Hospital
City
Shanghai
State/Province
Shanghai
ZIP/Postal Code
200000
Country
China

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
30822803
Citation
Chen YZ, Pan J, Luo YY, Jiang X, Zou WB, Qian YY, Zhou W, Liu X, Li ZS, Liao Z. Detachable string magnetically controlled capsule endoscopy for complete viewing of the esophagus and stomach. Endoscopy. 2019 Apr;51(4):360-364. doi: 10.1055/a-0856-6845. Epub 2019 Mar 1.
Results Reference
background
PubMed Identifier
31194028
Citation
Jiang X, Pan J, Li ZS, Liao Z. Standardized examination procedure of magnetically controlled capsule endoscopy. VideoGIE. 2019 May 30;4(6):239-243. doi: 10.1016/j.vgie.2019.03.003. eCollection 2019 Jun. No abstract available.
Results Reference
background
PubMed Identifier
32241897
Citation
Chiu PWY, Ng SC, Inoue H, Reddy DN, Ling Hu E, Cho JY, Ho LK, Hewett DG, Chiu HM, Rerknimitr R, Wang HP, Ho SH, Seo DW, Goh KL, Tajiri H, Kitano S, Chan FKL. Practice of endoscopy during COVID-19 pandemic: position statements of the Asian Pacific Society for Digestive Endoscopy (APSDE-COVID statements). Gut. 2020 Jun;69(6):991-996. doi: 10.1136/gutjnl-2020-321185. Epub 2020 Apr 2.
Results Reference
background
PubMed Identifier
27965879
Citation
Eldridge SM, Chan CL, Campbell MJ, Bond CM, Hopewell S, Thabane L, Lancaster GA; PAFS consensus group. CONSORT 2010 statement: extension to randomised pilot and feasibility trials. Pilot Feasibility Stud. 2016 Oct 21;2:64. doi: 10.1186/s40814-016-0105-8. eCollection 2016.
Results Reference
background
PubMed Identifier
31981648
Citation
Jiang B, Qian YY, Pan J, Jiang X, Wang YC, Zhu JH, Zou WB, Zhou W, Li ZS, Liao Z. Second-generation magnetically controlled capsule gastroscopy with improved image resolution and frame rate: a randomized controlled clinical trial (with video). Gastrointest Endosc. 2020 Jun;91(6):1379-1387. doi: 10.1016/j.gie.2020.01.027. Epub 2020 Jan 22.
Results Reference
background

Learn more about this trial

Feasibility of Non-contact Magnetically-controlled Capsule Endoscopy During COVID-19 Pandemic

We'll reach out to this number within 24 hrs