Effects of a Valved Feeding System in Late-preterm Newborns: the Safe Oral Feeding Trial (SOFT)
Primary Purpose
Premature Birth, Feeding; Difficult, Newborn, Feeding, Bottle
Status
Completed
Phase
Not Applicable
Locations
Italy
Study Type
Interventional
Intervention
Valved ergonomic teat
Standard silicon teat
Sponsored by
About this trial
This is an interventional treatment trial for Premature Birth focused on measuring late-preterm newborns, valved feeding system
Eligibility Criteria
Inclusion Criteria:
- Gestational age 34+0 - 36+6 weeks at birth;
- Exclusive oral feeding;
- Bottle-feeding for at least a meal a day;
Exclusion Criteria:
- Newborns with exclusive breastfeeding;
- Newborns with congenital anomalies, perinatal asphyxia, respiratory or neurological issues, genetic syndromes, infections, metabolic diseases;
- Ongoing administration of medication able to interfere with esophageal or respiratory function;
- Newborns who require respiratory support, including oxygen-therapy via nasal-cannula;
- Newborns who require oral or nasal feeding tube;
Sites / Locations
- Città della Salute e della Scienza - Ospedale S.Anna - University of Turin
Arms of the Study
Arm 1
Arm 2
Arm Type
Experimental
Sham Comparator
Arm Label
B-ESP
B-STD
Arm Description
B-ESP group will be fed with a feeding system with a valved ergonomic teat.
B-STD will be fed with a standard feeding system.
Outcomes
Primary Outcome Measures
Evaluating the level of coordination in the sucking-swallowing-breathing pattern in the B-ESP group compared with the B-STD
This evaluation will be recorded at 24 and 72 hours of life and defined from the suckings/swallowings ratio.
The literature describes this parameter as strongly associated to a higher maturity of the sucking-swallowing-breathing pattern; in fact, a ratio of sucking-swallowing-breathing of 1:1:1 describes the mature pattern, typical of the breastfeeding and considered the optimum for a newborn.
Secondary Outcome Measures
Coefficient of variation of time between sucking and swallowing
This coefficient is expressed in seconds. a lower coefficient corresponds to breastfeeding
Mean percentage of incidence of breaths that precede and follow the swallowings
This percentage is classified by Lau et al. (the average interval between two breathing acts monitored during a meal of an healthy at term newborn varies between 1.2-2 seconds)
Evaluation of the sucking processes
This evaluation is made through the a structured questionnaire composed by 31 items
Evaluation of cardiorespiratory stability
This evaluation is made considering frequency and characteristics of cardiorespiratory events (during and after meal administration)
Evaluation of meal tolerance
This evaluation is carried out considering the number of vomiting and regurgitations during and after the meal, volume in mL per meal, number of meals per day
Number of breastfed newborns at the time of dimission
Full Information
NCT ID
NCT04400175
First Posted
April 25, 2020
Last Updated
August 15, 2023
Sponsor
University of Turin, Italy
1. Study Identification
Unique Protocol Identification Number
NCT04400175
Brief Title
Effects of a Valved Feeding System in Late-preterm Newborns: the Safe Oral Feeding Trial
Acronym
SOFT
Official Title
Effects on Coordination of Sucking, Swallowing and Breathing Process of a Valved Feeding System in Late-preterm Newborns. The Safe Oral Feeding Trial (SOFT)
Study Type
Interventional
2. Study Status
Record Verification Date
August 2023
Overall Recruitment Status
Completed
Study Start Date
December 1, 2020 (Actual)
Primary Completion Date
May 31, 2023 (Actual)
Study Completion Date
May 31, 2023 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
University of Turin, Italy
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
Yes
5. Study Description
Brief Summary
Comparing with a randomized controlled trial two different feeding systems in two groups of late-preterm newborns for evaluating which is more efficient in promoting the coordination in the process of sucking-swallowing-breathing and better cardiorespiratory stability.
The B-ESP group will be fed with a feeding system with a valved ergonomic teat; the B-STD with a standard feeding system.
Detailed Description
The swallowing patterns are still immature in the newborn, especially if preterm. An incomplete synchronization in the process of sucking, swallowing and breathing could lead to some difficulty during feedings with desaturations and risk of milk inhalation in the upper airway tract. Moreover, a dysfunctional or immature pattern of sucking, swallowing and breathing also affect the post-prandial period, tiring the newborn and increasing the cardio-respiratory instability.
Breastfeeding promote the development of a physiological coordination of the process of sucking, swallowing and breathing, guaranteeing high and stable values of oxygenation during feedings. On the other hand, bottle-feeding could be responsible of a difficult coordination among the phases of swallowing and breathing. In an healthy, at term, brestfed newborn is observed a typical pattern of sucking-swallowing-expiration with a ratio of 1:1:1. In a bottlefed newborn this ratio is 2-12:1:4, with a relative increase of the period of sucking compared to the swallowing one, that could lead to apnoeas and desaturations.
The differences between the two feedings modality are more accentuated in the late-preterm newborn, which is more prone to cardio-respiratory instability compared to the healthy at term newborn, because of the immaturity of the respiratory centers in the brainstem, and of the processes responsible for the coordination of the sucking, swallowing and breathing .
However breastfeeding, in spite of the fact that is crucial for the development of the correct process of sucking, can be challenging in the premature infant because it requires a considerable physical effort.
Therefore, disposing of devices for nutrition able to facilitate oral feeding, simulating the physiologic breastfeeding, is necessary. In this way, we can contribute to the development of the proper sucking-swallowing-breathing pattern and to improve cardio-respiratory stability.
In literature there are multiple studies carried out on term newborns demonstrating the importance of the negative pressure or air vacuum created in the oral cavity, in order to promote the emptying of the lactiferous ducts and/or of the teat and simultaneously promote the maintainance of the right respiratory pattern. An ergonomic feeding system with a valve able to create vacuum could be able to respond to the demands of late preterm newborns.
Aim of the study is to evaluate the effects of a trial with an experimental feeding system with a teat with a valve able to facilitate the vacuum in the oral cavity on the pattern of sucking-swallowing and breathing in late preterm newborns.
NUMBER OF PATIENTS Precise data regarding swallowing/respiration rate in bottle-fed late preterm infants in the first 3 days of life are lacking in the literature. Considering a mean swallow/respiration ratio of 1.5 and a variance of 0.5, obtained from surveys performed at our center prior to the study, a sample size of 38 infants per arm was estimated to achieve 80% power to detect a 30% difference on the primary outcome with a significance level of 0.05.
STUDY DESIGN Late preterm newborns eligible to enter in the study, prior obtaining the informed consent from parents, will be assigned in the "B-ESP" or "B-STD" group through a process of block randomisation, controlled by a software.
Newborns included in the randomisation, after a training of 3 meals with the feeding bottle assigned from the randomisation, can be entered in the study.
Newborns included in the study will be monitored for the entire duration of a meal and the subsequent 3-hours period. This monitoring will be collected in two different times (T1 and T2): in the second day of life (24-48 hours of life) and in the fourth day of life (72-96 hours of life). The study includes an audio recording of the swallowings through a microphone in the room and the recordings of the process of sucking and swallowing through a cutaneous sensor.
In addition, a cardiorespiratory monitoring with a poligraph will be made, considering oxygen saturation, cardiac and respiratory frequency and electrocardiography. The meal's video recording will permit a subsequent classification of the sucking movements and the evaluation of any possible interference in the polygraphic recording.
FEEDING DEVICES
Newborns of the B-STD group will be fed using a classic disposable feeding device, which is actually in use in our centre and provided by our hospital, composed of:
a 150 mL feeding bottle in polypropylene, devoid of BPA;
a silicon teat, devoid of BPA, available in two types, (a slow graduated flow and a standard flow) depending on the necessities and suction abilities of the baby;
a protective plug.
Newborns of the B-ESP group will be fed using a feeding system with a valved ergonomic teat, composed of:
a slow-flow ergonomic silicon teat
polipropilene bottle with a capacity of 150 mL, with a ventilation valve on the bottom
silicon valve
Newborns will be fed with defined quantities of maternal milk or bank donated milk, based on weight and gestational age.
The meal will be administered by the caregiver (a parent or a nurse) previously trained. The meal's administration will be performed keeping the baby in the caregivers's arms in the ESL position (semielevated side-lying). At the end of the feeding process the newborn will be repositioned in his cradle in the supine position.
The cardiosaturimetric evaluation will be performed using a system of polygraphic monitoring, which allows a simultaneous non-invasive recording of cardiorespiratory parameters, noises and movements associated to the sucking and swallowing processes combined to video recordings.
The evaluation of the sucking process will be carried out using a structured questionnaire composed by 31 items, which allows to distinguish normal suction (mature) from disorganized and dysfunctional ones.
Considering simultaneously the cardiosaturimetric parameters, video, audio and cutaneous sensor's recordings, it is possible to obtain a more accurate evaluation of the processes of swallowing, sucking and breathing of the newborn during meal administration. It is also possible to identify the exact moment of the breathing process assigned to the newborn's swallowing.
CLINICAL DATA
At birth:
gestational age;
weight in grams;
z-score;
sex;
type of delivery;
peri-partum condition, including possible administration of prenatal corticosteroids;
type of support provided at birth;
At T1 and T2:
hours from birth;
weight;
z-score;
number of meals in a day;
type of milk administered;
overall volume administered expressed in mL in a day;
duration of a meal expressed in minutes;
number of regurgitation or vomit during the administration of a meal;
number of regurgitation or vomit after the admninistration of a meal;
At discharge:
weight;
z-score;
number of meals in a day;
type of feeding (exclusive breastfeeding; exckusive bottlefeeding or mixed)
overall volume administered expressed in mL in a day;
INSTRUMENTAL DATA
Number of suctions;
Number of swallowings;
Number of apnoeas;
Average duration of apnoeas;
Number of oxygen desaturations
Minimal oxygen saturation;
Number of reduction of cardiac frequency (bradycardia);
Minimal cardiac frequency. The definition of apnoea, oxygen desaturation and bradycardia applied in this study are the ones defined by literature (Di Fiore JM, Arko MK, Miller MJ, et al. Cardiorespiratory Events in Preterm Infants Referred for Apnea Monitoring Studies. PEDIATRICS. 2001;108(6):1304-1308.)
APNOEA: arrest of the breathing acts for a period of at least 20 seconds or arrest of the breathing acts for a period of at least 5 seconds associated with bradycardia and/or desaturations;
OXYGEN DESATURATIONS: reduction of the oxygen saturation (SpO2) <80% or of at least 5% compared to the baseline, for at least 4 seconds.
BRADYCARDIA: reduction of the cardiac frequency under 80 bpm for at least 4 seconds
STATISTICAL ANALYSIS
Statistical analysis will be carried out using the STATISTICA software package for Windows (StatSoft, Inc., Tulsa, Oklahoma, USA). Every newborn in the experimental group will be matched with a newborn of the control group similar for gestational age and weight. For the normal distribution, data will be tested with the Kolmogorov-Smirnov test and with the exploratory data analysis. Data will be expressed as statistical mean and standard deviation (SD) or as median and interquantile range depending on the relative distribution. The differences between the polisonnographic data will be evaluated with the Student's T test or through a similar non-parametric test depending on the distribution: Fisher test for comparison between categorical data and regression tests (linear and non-linear) for comparison between continuous variables. Statistical significance is set as p<0.05.
EXPECTED RESULTS
The more physiological administration of milk with a feeding system with a valved ergonomic teat, could better promote the development of coordination in the process of sucking-swallowing-breathing. Therefore inhalation and cardiosaturimetric events during a meal and immediately after will be reduced and therefore the newborn's oral feeding tolerance will increase, making it more similar to physiological breastfeeding.
Bottle-feeding milk administration with a feeding system with a valved ergonomic teat in the first days of life, the period when exclusive breastfeeding is more difficult, could also promote the transition between bottle-feeding to breastfeeding, because this mechanism is more similar to the physiological one.
If the results of this study will support this hypotesis, feeding system with a valved ergonomic teat could be chosen as a non-pharmacological treatment for late-preterm newborns who encounter difficulty in the oral feeding, such as cardio-respiratory instability during the sucking process and risk of milk inhalation when the breastfeeding is not possible.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Premature Birth, Feeding; Difficult, Newborn, Feeding, Bottle
Keywords
late-preterm newborns, valved feeding system
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Outcomes Assessor
Allocation
Randomized
Enrollment
40 (Actual)
8. Arms, Groups, and Interventions
Arm Title
B-ESP
Arm Type
Experimental
Arm Description
B-ESP group will be fed with a feeding system with a valved ergonomic teat.
Arm Title
B-STD
Arm Type
Sham Comparator
Arm Description
B-STD will be fed with a standard feeding system.
Intervention Type
Device
Intervention Name(s)
Valved ergonomic teat
Intervention Description
Administration of milk with a feeding system with a valved ergonomic teat in late preterm newborns.
Intervention Type
Device
Intervention Name(s)
Standard silicon teat
Intervention Description
Administration of milk with a feeding system with a standard silicon teat
Primary Outcome Measure Information:
Title
Evaluating the level of coordination in the sucking-swallowing-breathing pattern in the B-ESP group compared with the B-STD
Description
This evaluation will be recorded at 24 and 72 hours of life and defined from the suckings/swallowings ratio.
The literature describes this parameter as strongly associated to a higher maturity of the sucking-swallowing-breathing pattern; in fact, a ratio of sucking-swallowing-breathing of 1:1:1 describes the mature pattern, typical of the breastfeeding and considered the optimum for a newborn.
Time Frame
Calculated throughout 72 hours
Secondary Outcome Measure Information:
Title
Coefficient of variation of time between sucking and swallowing
Description
This coefficient is expressed in seconds. a lower coefficient corresponds to breastfeeding
Time Frame
Calculated throughout 72 hours
Title
Mean percentage of incidence of breaths that precede and follow the swallowings
Description
This percentage is classified by Lau et al. (the average interval between two breathing acts monitored during a meal of an healthy at term newborn varies between 1.2-2 seconds)
Time Frame
Calculated throughout 72 hours
Title
Evaluation of the sucking processes
Description
This evaluation is made through the a structured questionnaire composed by 31 items
Time Frame
Calculated throughout 72 hours
Title
Evaluation of cardiorespiratory stability
Description
This evaluation is made considering frequency and characteristics of cardiorespiratory events (during and after meal administration)
Time Frame
Calculated throughout 72 hours
Title
Evaluation of meal tolerance
Description
This evaluation is carried out considering the number of vomiting and regurgitations during and after the meal, volume in mL per meal, number of meals per day
Time Frame
Calculated throughout 72 hours
Title
Number of breastfed newborns at the time of dimission
Time Frame
Calculated throughout 72 hours
10. Eligibility
Sex
All
Minimum Age & Unit of Time
1 Day
Maximum Age & Unit of Time
5 Days
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Gestational age 34+0 - 36+6 weeks at birth;
Exclusive oral feeding;
Bottle-feeding for at least a meal a day;
Exclusion Criteria:
Newborns with exclusive breastfeeding;
Newborns with congenital anomalies, perinatal asphyxia, respiratory or neurological issues, genetic syndromes, infections, metabolic diseases;
Ongoing administration of medication able to interfere with esophageal or respiratory function;
Newborns who require respiratory support, including oxygen-therapy via nasal-cannula;
Newborns who require oral or nasal feeding tube;
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Francesco Cresi, MD; PhD
Organizational Affiliation
Città della Salute e della Scienza - Ospedale S.Anna - University of Turin
Official's Role
Principal Investigator
Facility Information:
Facility Name
Città della Salute e della Scienza - Ospedale S.Anna - University of Turin
City
Turin
ZIP/Postal Code
10126
Country
Italy
12. IPD Sharing Statement
Citations:
PubMed Identifier
29054835
Citation
Joshi R, van Pul C, Sanders A, Weda H, Bikker JW, Feijs L, Andriessen P. A Strategy to Reduce Critical Cardiorespiratory Alarms due to Intermittent Enteral Feeding of Preterm Neonates in Intensive Care. Interact J Med Res. 2017 Oct 20;6(2):e20. doi: 10.2196/ijmr.7756.
Results Reference
background
PubMed Identifier
9174231
Citation
Poets CF, Langner MU, Bohnhorst B. Effects of bottle feeding and two different methods of gavage feeding on oxygenation and breathing patterns in preterm infants. Acta Paediatr. 1997 Apr;86(4):419-23. doi: 10.1111/j.1651-2227.1997.tb09034.x.
Results Reference
background
PubMed Identifier
28324898
Citation
Gross RD, Trapani-Hanasewych M. Breathing and Swallowing: The Next Frontier. Semin Speech Lang. 2017 Apr;38(2):87-95. doi: 10.1055/s-0037-1599106. Epub 2017 Mar 21.
Results Reference
background
PubMed Identifier
11138220
Citation
Chen CH, Wang TM, Chang HM, Chi CS. The effect of breast- and bottle-feeding on oxygen saturation and body temperature in preterm infants. J Hum Lact. 2000 Feb;16(1):21-7. doi: 10.1177/089033440001600105.
Results Reference
background
PubMed Identifier
16940236
Citation
Goldfield EC, Richardson MJ, Lee KG, Margetts S. Coordination of sucking, swallowing, and breathing and oxygen saturation during early infant breast-feeding and bottle-feeding. Pediatr Res. 2006 Oct;60(4):450-5. doi: 10.1203/01.pdr.0000238378.24238.9d. Epub 2006 Aug 28.
Results Reference
background
PubMed Identifier
26658121
Citation
Simmer K, Kok C, Nancarrow K, Hepworth AR, Geddes DT. Novel feeding system to promote establishment of breastfeeds after preterm birth: a randomized controlled trial. J Perinatol. 2016 Mar;36(3):210-5. doi: 10.1038/jp.2015.184. Epub 2015 Dec 10.
Results Reference
background
PubMed Identifier
16627890
Citation
Mizuno K, Ueda A. Changes in sucking performance from nonnutritive sucking to nutritive sucking during breast- and bottle-feeding. Pediatr Res. 2006 May;59(5):728-31. doi: 10.1203/01.pdr.0000214993.82214.1c.
Results Reference
background
PubMed Identifier
3237449
Citation
Mathew OP. Respiratory control during nipple feeding in preterm infants. Pediatr Pulmonol. 1988;5(4):220-4. doi: 10.1002/ppul.1950050408.
Results Reference
background
Citation
Ward, N. Feeding and Swallowing Disorders in Infancy: Assessment and Management. J. Hum. Lact. 11, 147-147 (1995)
Results Reference
background
PubMed Identifier
26319112
Citation
Sakalidis VS, Geddes DT. Suck-Swallow-Breathe Dynamics in Breastfed Infants. J Hum Lact. 2016 May;32(2):201-11; quiz 393-5. doi: 10.1177/0890334415601093. Epub 2015 Aug 28.
Results Reference
background
PubMed Identifier
27461200
Citation
Dalgleish SR, Kostecky LL, Blachly N. Eating in "SINC": Safe Individualized Nipple-Feeding Competence, a Quality Improvement Project to Explore Infant-Driven Oral Feeding for Very Premature Infants Requiring Noninvasive Respiratory Support. Neonatal Netw. 2016;35(4):217-27. doi: 10.1891/0730-0832.35.4.217.
Results Reference
background
PubMed Identifier
22131865
Citation
Whyte R. Safe discharge of the late preterm infant. Paediatr Child Health. 2010 Dec;15(10):655-66. doi: 10.1093/pch/15.10.655.
Results Reference
background
PubMed Identifier
24182956
Citation
Meier P, Patel AL, Wright K, Engstrom JL. Management of breastfeeding during and after the maternity hospitalization for late preterm infants. Clin Perinatol. 2013 Dec;40(4):689-705. doi: 10.1016/j.clp.2013.07.014. Epub 2013 Sep 21.
Results Reference
background
PubMed Identifier
26791183
Citation
Lau C. Development of infant oral feeding skills: what do we know? Am J Clin Nutr. 2016 Feb;103(2):616S-21S. doi: 10.3945/ajcn.115.109603. Epub 2016 Jan 20.
Results Reference
background
PubMed Identifier
22119233
Citation
Geddes DT, Sakalidis VS, Hepworth AR, McClellan HL, Kent JC, Lai CT, Hartmann PE. Tongue movement and intra-oral vacuum of term infants during breastfeeding and feeding from an experimental teat that released milk under vacuum only. Early Hum Dev. 2012 Jun;88(6):443-9. doi: 10.1016/j.earlhumdev.2011.10.012. Epub 2011 Nov 26.
Results Reference
background
PubMed Identifier
26964010
Citation
Cannon AM, Sakalidis VS, Lai CT, Perrella SL, Geddes DT. Vacuum characteristics of the sucking cycle and relationships with milk removal from the breast in term infants. Early Hum Dev. 2016 May;96:1-6. doi: 10.1016/j.earlhumdev.2016.02.003. Epub 2016 Mar 8.
Results Reference
background
PubMed Identifier
20542296
Citation
da Costa SP, van der Schans CP, Zweens MJ, Boelema SR, van der Meij E, Boerman MA, Bos AF. The development of sucking patterns in preterm, small-for-gestational age infants. J Pediatr. 2010 Oct;157(4):603-9, 609.e1-3. doi: 10.1016/j.jpeds.2010.04.037. Epub 2010 Jun 14.
Results Reference
background
PubMed Identifier
21962771
Citation
Fucile S, McFarland DH, Gisel EG, Lau C. Oral and nonoral sensorimotor interventions facilitate suck-swallow-respiration functions and their coordination in preterm infants. Early Hum Dev. 2012 Jun;88(6):345-50. doi: 10.1016/j.earlhumdev.2011.09.007. Epub 2011 Sep 29.
Results Reference
background
PubMed Identifier
12856985
Citation
Lau C, Smith EO, Schanler RJ. Coordination of suck-swallow and swallow respiration in preterm infants. Acta Paediatr. 2003 Jun;92(6):721-7.
Results Reference
background