The Efficacy and Safety of Faster Insulin Aspart (Fiasp®) Compared to Conventional Insulin Aspart (NovoLog®) as Correction Bolus (PLATEAU)

Primary Purpose

Type 1 Diabetes Mellitus

Status
Unknown status
Phase
Phase 4
Locations
United States
Study Type
Interventional
Intervention
Faster Insulin Aspart (Fiasp®)
Sponsored by
Mountain Diabetes and Endocrine Center
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Type 1 Diabetes Mellitus focused on measuring continuous glucose monitoring, continuous subcutaneous insulin infusion, hyperglycemia, correction bolus

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Male and female patients > 18 years of age
  • Type 1 DM of > 1 year duration
  • Use of any open loop insulin pump, Tandem T-Slim with Basal IQ, Insulet Omnipod Dash, or any other investigator-approved insulin pumps with Dexcom CGM G5, G6, or newer version for > 6 months
  • Good baseline glycemic control (HbA1c < 7.5%; low risk of hypoglycemia by CGM as defined by Dexcom Clarity report)
  • No episodes of severe hypoglycemia in the previous 3 months
  • Pump download shows regular meal bolusing, accurate carbohydrate counting ability, and willingness to use exercise markers in Dexcom
  • CGM download shows regular use (>85% of time) and regular calibration if using G5 sensor (G6 requires no calibration)
  • Females using adequate contraception

Exclusion Criteria:

  • Use of CGM other than Dexcom G5 or G6 or a newer Dexcom CGM version
  • Suboptimal baseline glycemic control (HbA1c > 7.5%)
  • Pump or CGM download shows suboptimal use of devices (lack of meal boluses, frequent overrides of pump, excessive pump suspension, inadequate calibration or inconsistent usage of CGM)
  • Serious comorbidities including CVD with recent event, actively treated malignancy, renal dysfunction with eGFR < 45 ml/min, or any other condition which in the opinion of the investigator would preclude subject's ability to participate in trial
  • Females unwilling to use contraception, planning pregnancy or breastfeeding
  • Use of any other glucose-lowering agents than insulin
  • Hypersensitivity to insulin aspart or one of the excipients in faster insulin aspart
  • Known diabetic gastroparesis

Sites / Locations

  • Mountain Diabetes and Endocrine CenterRecruiting

Arms of the Study

Arm 1

Arm 2

Arm Type

No Intervention

Active Comparator

Arm Label

No Intervention: Conventional Insulin Aspart (NovoLog®)

Faster Insulin Aspart (Fiasp®)

Arm Description

In the aspart group, the subject will only take aspart through the their pump. This study population will have an established expertise in diabetes self-management with previous knowledge of insulin pump therapy and Dexcom Continuous Glucose Monitoring (CGM). Allowing the subjects to use their insulin pumps for bolus insulin delivery, as they are accustomed, will minimize the chances of skipping meal boluses and correction doses. Aspart is put into their pump and delivered to their body through a small tube placed under your skin. In this NovoLog®-only treatment group, the subject will take aspart with each meal while your pump also gives you a slow, continuous dose of aspart for basal insulin. This treatment group is very similar (or even identical) to the treatment the subject was receiving prior to starting the study.

In the Fiasp group, the subject will only take aspart through the their pump. This study population will have an established expertise in diabetes self-management with previous knowledge of insulin pump therapy and Dexcom Continuous Glucose Monitoring (CGM). Allowing the subjects to use their insulin pumps for bolus insulin delivery, as they are accustomed, will minimize the chances of skipping meal boluses and correction doses. Fiasp is put into their pump and delivered to their body through a small tube placed under their skin. In this Fiasp treatment group, the subject will take fiasp with each meal while their pump also gives them a slow, continuous dose of aspart for basal insulin. This treatment group is very similar (or even identical) to the treatment the subject was receiving prior to starting the study.

Outcomes

Primary Outcome Measures

Time to stabilization of rising blood sugar by CGM after correction bolus
Time (in minutes) to stabilization of rising blood sugar (GPP) by CGM after correction bolus during the final 2 week maintenance period. Two categories of correction dose will be analyzed: 1) those following an isolated correction dose (taken independently of a meal dose), and 2) those taken as part of a combination bolus with a meal dose.

Secondary Outcome Measures

Incidence of early hypoglycemia
Incidence of early hypoglycemia (Blood glucose < 54 mg/dl within 1 and 2 hours) following correction bolus with each insulin (Key Safety Endpoint)
Change in Insulin Sensitivity Factor
Change in Insulin Sensitivity Factor, if any, required for hypoglycemia prevention using Fiasp as recorded by continuous subcutaneous insulin infusion device setting report
Change in Insulin On Board
Change in Insulin On Board, if any, required for prevention of late hyperglycemia using Fiasp as recorded by continuous subcutaneous insulin infusion device setting report
GlycoMark differences between arms
GlycoMark (1,5 anhydroglucitol, a marker of postprandial glucose excursion) during use of each insulin.
HbA1c differences between arms
HbA1c during use of each insulin
Percent time spent in target range, hyperglycemic range, and hypoglycemic range
Percent time spent in target range, hyperglycemic range and hypoglycemic range by Continuous Glucose Monitoring (CGM) on each insulin during the final 2 weeks of each treatment period. Target ranges include 70-180 mg/dL. Hyperglycemia ranges to be captured will include Category 1: 181-250 mg/dL and Category 2: above 250 mg/dL. Hypoglycemia ranges to be captured include Category 1: 69-54 mg/dL and Category 2: below 54 mg/dL.
Standard deviation differences between arms
Standard deviation of mean blood glucose as determined by CGM on each insulin
Treatment related impact measures between arms
Treatment related impact measures on each insulin using TRIM D questionnaire

Full Information

First Posted
May 26, 2020
Last Updated
November 20, 2020
Sponsor
Mountain Diabetes and Endocrine Center
search

1. Study Identification

Unique Protocol Identification Number
NCT04414579
Brief Title
The Efficacy and Safety of Faster Insulin Aspart (Fiasp®) Compared to Conventional Insulin Aspart (NovoLog®) as Correction Bolus
Acronym
PLATEAU
Official Title
The Efficacy and Safety of Faster Insulin Aspart (Fiasp®) Compared to Conventional Insulin Aspart (NovoLog®) as Correction Bolus in Patients With Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion (CSII) and Continuous Glucose Monitoring (CGM): a Cross-over Controlled Trial
Study Type
Interventional

2. Study Status

Record Verification Date
November 2020
Overall Recruitment Status
Unknown status
Study Start Date
March 27, 2019 (Actual)
Primary Completion Date
March 2021 (Anticipated)
Study Completion Date
March 2021 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Mountain Diabetes and Endocrine Center

4. Oversight

Studies a U.S. FDA-regulated Drug Product
Yes
Studies a U.S. FDA-regulated Device Product
No
Product Manufactured in and Exported from the U.S.
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
The purpose of this investigator-initiated trial is to compare the efficacy in terms of time to recovery from hyperglycemia as measured by time to arrest of hyperglycemic excursion ("glucose plateau point", primary endpoint) and return to premeal glucose target if feasible (secondary endpoint) between Fiasp and conventional insulin aspart when used as a correction bolus. These endpoints will be determined by CGM (Dexcom) from data exported from the Dexcom Clarity program.
Detailed Description
Patients with type 1 DM using CSII require bolus insulin for two purposes: first, to cover carbohydrate intake to control postprandial glucose, and second, to correct episodes of hyperglycemia. The latter function is referred to as a "correction dose" or "correction bolus". Insulin pumps have bolus calculators which calculate correction doses based on the patient's individualized BG target and insulin sensitivity factor (ISF). Rapid-acting insulin analogues delivered by pump typically require 2 to 4 hours to fully correct an acute hyperglycemic episode, and sometimes multiple correction doses are needed to normalize the blood glucose level. This can be frustrating for patients, particularly when a correction bolus is necessary in addition to a meal bolus; frequently, patients must wait for the correction bolus to take effect and delay eating until the blood glucose has begun to normalize to avoid severe postprandial hyperglycemia. There is consequently an unmet need in insulin delivery, and in particular in CSII, for an insulin which can correct a hyperglycemic episode more rapidly than is currently possible with rapid-acting insulin analogues. Faster insulin aspart (Fiasp) is a novel formulation of insulin aspart with an accelerated time-action profile which results in twice the exposure to insulin and 74% greater insulin action within the first 30 minutes after injection compared to conventional insulin aspart. This results in twice-as-fast onset of appearance in the bloodstream (4 vs. 9 min compared to conventional insulin aspart) which has been demonstrated to reduce postprandial glucose levels in patients with type 1 DM using CSII. Theoretically, this faster insulin action would be useful in correction dosing during acute episodes of hyperglycemia to normalize the blood glucose level more rapidly than is currently possible with conventional insulin aspart (NovoLog). Many patients with type 1 DM using CSII now also use continuous glucose monitoring (CGM) for making insulin dosing decisions. Currently the FDA has approved 2 CGM systems for nonadjunctive use in bolus insulin dose calculations. Only one of these systems, the Dexcom, reads continuously to the patient and has alarms to warn of impending episodes of hyper- or hypoglycemia, and this is the system used most commonly by patients with type 1 DM using open-loop CSII. Patients now incorporate the Dexcom trend arrow, which depicts the rate and direction of glucose change, into the correction dose calculation, and recommendations on how to incorporate CGM information into correction dose calculations have recently been updated based on an expert consensus report. However, these guidelines were created for use with rapid acting insulin analogues. How they might need to be modified for use with Fiasp (the first and only ultra-rapid insulin analogue) is not known. The purpose of this investigator-initiated trial is to compare the efficacy in terms of time to recovery from hyperglycemia as measured by time to arrest of hyperglycemic excursion ("glucose plateau point", primary endpoint) and return to premeal glucose target if feasible (secondary endpoint) between Fiasp and conventional insulin aspart when used as a correction bolus. These endpoints will be determined by CGM (Dexcom) from data exported from the Dexcom Clarity program. Study hypothesis: Compared to conventional insulin aspart, Fiasp will correct hyperglycemia (defined as arrest of rise of blood glucose, following correction bolus, ie, GPP ) faster than conventional insulin aspart in subjects with type 1 DM using CSII.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Type 1 Diabetes Mellitus
Keywords
continuous glucose monitoring, continuous subcutaneous insulin infusion, hyperglycemia, correction bolus

7. Study Design

Primary Purpose
Treatment
Study Phase
Phase 4
Interventional Study Model
Crossover Assignment
Model Description
This is a 25-week open-label prospective single center 2 arm crossover trial consisting of a CSII settings (basal, bolus, and correction factors) will be optimized for a 2-week run in period followed by a 10-week period of CSII use with the assigned insulin. After a 12-week maintenance period, each group will cross over to the other insulin (conventional insulin aspart or Fiasp) by CSII for a second 2-week optimization period followed by a 10-week treatment period.
Masking
None (Open Label)
Masking Description
This is an open-label crossover trial. Subjects will be randomized to treatment sequence (Fiasp then NovoLog or NovoLog then Fiasp), each for a 12-week treatment period, by CSII. Randomization sequence will be determined by computerized randomization program. All patients will receive both treatments unless they drop out. Dropouts are unlikely since the participants are all regular continuing patients of the site's clinical practice.
Allocation
Randomized
Enrollment
45 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
No Intervention: Conventional Insulin Aspart (NovoLog®)
Arm Type
No Intervention
Arm Description
In the aspart group, the subject will only take aspart through the their pump. This study population will have an established expertise in diabetes self-management with previous knowledge of insulin pump therapy and Dexcom Continuous Glucose Monitoring (CGM). Allowing the subjects to use their insulin pumps for bolus insulin delivery, as they are accustomed, will minimize the chances of skipping meal boluses and correction doses. Aspart is put into their pump and delivered to their body through a small tube placed under your skin. In this NovoLog®-only treatment group, the subject will take aspart with each meal while your pump also gives you a slow, continuous dose of aspart for basal insulin. This treatment group is very similar (or even identical) to the treatment the subject was receiving prior to starting the study.
Arm Title
Faster Insulin Aspart (Fiasp®)
Arm Type
Active Comparator
Arm Description
In the Fiasp group, the subject will only take aspart through the their pump. This study population will have an established expertise in diabetes self-management with previous knowledge of insulin pump therapy and Dexcom Continuous Glucose Monitoring (CGM). Allowing the subjects to use their insulin pumps for bolus insulin delivery, as they are accustomed, will minimize the chances of skipping meal boluses and correction doses. Fiasp is put into their pump and delivered to their body through a small tube placed under their skin. In this Fiasp treatment group, the subject will take fiasp with each meal while their pump also gives them a slow, continuous dose of aspart for basal insulin. This treatment group is very similar (or even identical) to the treatment the subject was receiving prior to starting the study.
Intervention Type
Drug
Intervention Name(s)
Faster Insulin Aspart (Fiasp®)
Other Intervention Name(s)
Conventional Insulin Aspart (NovoLog®)
Intervention Description
Subjects will be randomized either to use Fiasp or conventional insulin aspart in CSII. CSII settings (basal, bolus, and correction factors) will be optimized using a meal challenge for a 2-week run in period followed by a 10-week period of CSII use with the assigned insulin. After a 12-week maintenance period, each group will cross over to the other insulin (conventional insulin aspart or Fiasp) by CSII for a second 2-week optimization period followed by a 10-week treatment period.
Primary Outcome Measure Information:
Title
Time to stabilization of rising blood sugar by CGM after correction bolus
Description
Time (in minutes) to stabilization of rising blood sugar (GPP) by CGM after correction bolus during the final 2 week maintenance period. Two categories of correction dose will be analyzed: 1) those following an isolated correction dose (taken independently of a meal dose), and 2) those taken as part of a combination bolus with a meal dose.
Time Frame
2 weeks
Secondary Outcome Measure Information:
Title
Incidence of early hypoglycemia
Description
Incidence of early hypoglycemia (Blood glucose < 54 mg/dl within 1 and 2 hours) following correction bolus with each insulin (Key Safety Endpoint)
Time Frame
25 weeks
Title
Change in Insulin Sensitivity Factor
Description
Change in Insulin Sensitivity Factor, if any, required for hypoglycemia prevention using Fiasp as recorded by continuous subcutaneous insulin infusion device setting report
Time Frame
25 weeks
Title
Change in Insulin On Board
Description
Change in Insulin On Board, if any, required for prevention of late hyperglycemia using Fiasp as recorded by continuous subcutaneous insulin infusion device setting report
Time Frame
25 weeks
Title
GlycoMark differences between arms
Description
GlycoMark (1,5 anhydroglucitol, a marker of postprandial glucose excursion) during use of each insulin.
Time Frame
25 weeks
Title
HbA1c differences between arms
Description
HbA1c during use of each insulin
Time Frame
25 weeks
Title
Percent time spent in target range, hyperglycemic range, and hypoglycemic range
Description
Percent time spent in target range, hyperglycemic range and hypoglycemic range by Continuous Glucose Monitoring (CGM) on each insulin during the final 2 weeks of each treatment period. Target ranges include 70-180 mg/dL. Hyperglycemia ranges to be captured will include Category 1: 181-250 mg/dL and Category 2: above 250 mg/dL. Hypoglycemia ranges to be captured include Category 1: 69-54 mg/dL and Category 2: below 54 mg/dL.
Time Frame
4 weeks
Title
Standard deviation differences between arms
Description
Standard deviation of mean blood glucose as determined by CGM on each insulin
Time Frame
4 weeks
Title
Treatment related impact measures between arms
Description
Treatment related impact measures on each insulin using TRIM D questionnaire
Time Frame
6 weeks

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Male and female patients > 18 years of age Type 1 DM of > 1 year duration Use of any open loop insulin pump, Tandem T-Slim with Basal IQ, Insulet Omnipod Dash, or any other investigator-approved insulin pumps with Dexcom CGM G5, G6, or newer version for > 6 months Good baseline glycemic control (HbA1c < 7.5%; low risk of hypoglycemia by CGM as defined by Dexcom Clarity report) No episodes of severe hypoglycemia in the previous 3 months Pump download shows regular meal bolusing, accurate carbohydrate counting ability, and willingness to use exercise markers in Dexcom CGM download shows regular use (>85% of time) and regular calibration if using G5 sensor (G6 requires no calibration) Females using adequate contraception Exclusion Criteria: Use of CGM other than Dexcom G5 or G6 or a newer Dexcom CGM version Suboptimal baseline glycemic control (HbA1c > 7.5%) Pump or CGM download shows suboptimal use of devices (lack of meal boluses, frequent overrides of pump, excessive pump suspension, inadequate calibration or inconsistent usage of CGM) Serious comorbidities including CVD with recent event, actively treated malignancy, renal dysfunction with eGFR < 45 ml/min, or any other condition which in the opinion of the investigator would preclude subject's ability to participate in trial Females unwilling to use contraception, planning pregnancy or breastfeeding Use of any other glucose-lowering agents than insulin Hypersensitivity to insulin aspart or one of the excipients in faster insulin aspart Known diabetic gastroparesis
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Wendy S Lane, MD
Phone
8286849588
Email
mountaindiabetes@msn.com
First Name & Middle Initial & Last Name or Official Title & Degree
Melinda L Buford, RN, BSN
Phone
8286849588
Ext
314
Email
mbuford@mdecresearch.com
Facility Information:
Facility Name
Mountain Diabetes and Endocrine Center
City
Asheville
State/Province
North Carolina
ZIP/Postal Code
28803
Country
United States
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Melinda L Buford, RN, BSN
Phone
828-684-9588
Ext
314
Email
mbuford@mdecresearch.com
First Name & Middle Initial & Last Name & Degree
Stephen L Weinrib, MD
First Name & Middle Initial & Last Name & Degree
Lynn L Baru, MD
First Name & Middle Initial & Last Name & Degree
Michael D Skrzynski, ANP

12. IPD Sharing Statement

Plan to Share IPD
Yes
IPD Sharing Plan Description
Data and statistical analysis will be available to any researcher with appropriate request
IPD Sharing Time Frame
post-study, up to 5 years
IPD Sharing Access Criteria
email Principal Investigator
Citations:
PubMed Identifier
28055230
Citation
Bode BW, Johnson JA, Hyveled L, Tamer SC, Demissie M. Improved Postprandial Glycemic Control with Faster-Acting Insulin Aspart in Patients with Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion. Diabetes Technol Ther. 2017 Jan;19(1):25-33. doi: 10.1089/dia.2016.0350. Epub 2017 Jan 5.
Results Reference
background
PubMed Identifier
29344577
Citation
Aleppo G, Laffel LM, Ahmann AJ, Hirsch IB, Kruger DF, Peters A, Weinstock RS, Harris DR. A Practical Approach to Using Trend Arrows on the Dexcom G5 CGM System for the Management of Adults With Diabetes. J Endocr Soc. 2017 Nov 20;1(12):1445-1460. doi: 10.1210/js.2017-00388. eCollection 2017 Dec 1.
Results Reference
background
PubMed Identifier
28205039
Citation
Heise T, Pieber TR, Danne T, Erichsen L, Haahr H. A Pooled Analysis of Clinical Pharmacology Trials Investigating the Pharmacokinetic and Pharmacodynamic Characteristics of Fast-Acting Insulin Aspart in Adults with Type 1 Diabetes. Clin Pharmacokinet. 2017 May;56(5):551-559. doi: 10.1007/s40262-017-0514-8.
Results Reference
background
PubMed Identifier
28356319
Citation
Russell-Jones D, Bode BW, De Block C, Franek E, Heller SR, Mathieu C, Philis-Tsimikas A, Rose L, Woo VC, Osterskov AB, Graungaard T, Bergenstal RM. Fast-Acting Insulin Aspart Improves Glycemic Control in Basal-Bolus Treatment for Type 1 Diabetes: Results of a 26-Week Multicenter, Active-Controlled, Treat-to-Target, Randomized, Parallel-Group Trial (onset 1). Diabetes Care. 2017 Jul;40(7):943-950. doi: 10.2337/dc16-1771. Epub 2017 Mar 29.
Results Reference
background
PubMed Identifier
27629148
Citation
Bergenstal RM, Garg S, Weinzimer SA, Buckingham BA, Bode BW, Tamborlane WV, Kaufman FR. Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes. JAMA. 2016 Oct 4;316(13):1407-1408. doi: 10.1001/jama.2016.11708. No abstract available.
Results Reference
background
PubMed Identifier
30537180
Citation
Klonoff DC, Evans ML, Lane W, Kempe HP, Renard E, DeVries JH, Graungaard T, Hyseni A, Gondolf T, Battelino T. A randomized, multicentre trial evaluating the efficacy and safety of fast-acting insulin aspart in continuous subcutaneous insulin infusion in adults with type 1 diabetes (onset 5). Diabetes Obes Metab. 2019 Apr;21(4):961-967. doi: 10.1111/dom.13610. Epub 2019 Jan 13.
Results Reference
background

Learn more about this trial

The Efficacy and Safety of Faster Insulin Aspart (Fiasp®) Compared to Conventional Insulin Aspart (NovoLog®) as Correction Bolus