transShield Embolic Protection System Feasibility Study
Primary Purpose
Aortic Stenosis
Status
Recruiting
Phase
Not Applicable
Locations
International
Study Type
Interventional
Intervention
transShield Embolic Protection System
Sponsored by
About this trial
This is an interventional treatment trial for Aortic Stenosis
Eligibility Criteria
Inclusion Criteria:
Patients must meet all of the following criteria to be eligible for participation in the study:
- Patient is >18 years old
- Patient is scheduled for percutaneous TAVR with up to 20French compatible commercial TAVR system
- Patient meets indications for TAVR per the device Instructions For Use
- The diameter of the artery at the site of the filter placement is between 28 mm and 42 mm
- Size and condition of the femoral artery iliac arteries are appropriate for the 12French transShield Expandable Introducer and 20F Embolic Protection Device
- Patient, or authorized representative, signs a written Informed Consent form to participate in the study, prior to any study mandated procedures
- Patient is willing and able to complete follow-up requirements
Exclusion Criteria:
Patients must be EXCLUDED from participation in this study if any of the following criteria are met:
- Patient not undergoing TAVR via the trans-femoral route
- Carotid artery stenosis >70% in either carotid artery
- Severe vascular tortuosity or anatomy that would preclude the safe introduction of the device
- Aortic valve is a congenital unicuspid or congenital bicuspid valve or is non-calcified
- Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation >3+)
- A known contraindication or hypersensitivity to all anticoagulation regimens or an inability to undergo anticoagulation for the study procedure
- History of bleeding diathesis or in whom anticoagulant and/or anti-platelet therapy is contraindicated, patients who will refuse transfusion, or havean active peptic ulcer or upper GI bleeding within the prior 3 months
- Renal insufficiency, defined as a creatinine level > 221μmol/L and/or end-stage renal disease requiring chronic dialysis at time of treatment
- History of stroke or transient ischemic attack (TIA) within prior 6 months
- Evidence of an acute myocardial infarction (MI) within prior 30 days
- Hemodynamic or respiratory instability requiring inotropic support, mechanical ventilation, or mechanical heart assistance within prior 30 days
- Hypertrophic cardiomyopathy with or without obstruction
- Need for emergency surgery for any reason
- Severe left ventricular (LV) dysfunction with LV ejection fraction (LVEF) <20%
- Severe pulmonary hypertension and right ventricular (RV) dysfunction
- Echocardiographic evidence of intracardiac mass, thrombus or vegetation
- Life expectancy < 12 months due to non-cardiac co-morbid conditions
- Evidence of active systemic or local groin infection
- Significant aortic disease, including abdominal aortic or thoracic aneurysm defined as maximal luminal diameter 5cm or greater; marked tortuosity (hyperacute bend), aortic arch atheroma or narrowing (especially with calcification and surface irregularities) of the abdominal or thoracic aorta, severe "unfolding" and tortuosity of the thoracic aorta
- Known hypersensitivity or contraindication to aspirin, heparin, ticlopidine, or clopidogrel, or sensitivity to contrast media, that cannot be managed with premedication
- Planned other cardiac surgical procedure within 2 weeks prior to, or planned cardiac surgical or interventional procedure within 30 days after the TAVR procedure. Note: Diagnostic cardiac catheterization is permitted within 10 days prior to the TAVR procedure
- Neurodegenerative or other progressive neurological disease
- Known allergy to any device component
- Known or suspected to be pregnant or lactating
- Currently enrolled in an investigational drug or device clinical study in which the primary endpoint has not occurred
- Patient has other medical, social or psychological problem that in the opinion of the investigator precludes them from participating
Sites / Locations
- Auckland City HospitalRecruiting
- Waikato HospitalRecruiting
- Policlinica Metropolitana, C.ARecruiting
- Ascardio Asociación Cardiovascular CentroccidentalRecruiting
Arms of the Study
Arm 1
Arm Type
Experimental
Arm Label
Single arm
Arm Description
Patients with severe native aortic valve stenosis who meet the commercially approved indications for TAVR.
Outcomes
Primary Outcome Measures
Safety - Incidence of 30-Day combined rate of the following events directly related to the transShield EPS as defined by VARC-2
Major Adverse Cardiac and Cerebrovascular Events (MACCE)
All cause mortality
All cause stroke (disabling and non-disabling)
Acute kidney injury (Stage 2 or 3)
Major vascular complications
Performance - Technical Success defined as the transShield EPS ability to perform all the following functions without adjudicated device malfunction
Ability to successfully deploy the device in the correct anatomical position, in the ascending aorta without interference with TAVR procedure/devices
Ability to retrieve and remove the device intact, including no visual evidence of any filter damage
Secondary Outcome Measures
Safety - Incidence of minor vascular complications directly related to the transShield EPS as defined by VARC-2.
As defined by VARC-2.
Incidence of peri-procedural disabling stroke as defined by a modified Rankin Scale (mRS) score of 2 or more at 30 days and an increase in at least one mRS category from an individual's pre-stroke baseline.
Full Information
NCT ID
NCT04585308
First Posted
October 5, 2020
Last Updated
September 14, 2022
Sponsor
TransAortic Medical, Inc.
1. Study Identification
Unique Protocol Identification Number
NCT04585308
Brief Title
transShield Embolic Protection System Feasibility Study
Official Title
Prospective, Multi-center, Single-Arm Feasibility Study of the transShield Embolic Protection System
Study Type
Interventional
2. Study Status
Record Verification Date
September 2022
Overall Recruitment Status
Recruiting
Study Start Date
December 15, 2020 (Actual)
Primary Completion Date
September 2023 (Anticipated)
Study Completion Date
September 2023 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
TransAortic Medical, Inc.
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Product Manufactured in and Exported from the U.S.
Yes
Data Monitoring Committee
No
5. Study Description
Brief Summary
The objective of this study is to evaluate the safety and performance of the transShield Embolic Protection System (EPS) used for embolic protection during Transcatheter Aortic Valve Replacement (TAVR).
Detailed Description
This is a prospective, multi-center, single arm feasibility study to assess the safety and performance of the transShield EPS. Patients with severe native aortic valve stenosis scheduled for TAVR will be screened for study eligibility. Subjects who meet the commercially approved indications for TAVR and comply with the study inclusion/exclusion criteria are eligible for enrollment. Patients will be followed for 30 days post procedure.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Aortic Stenosis
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
50 (Anticipated)
8. Arms, Groups, and Interventions
Arm Title
Single arm
Arm Type
Experimental
Arm Description
Patients with severe native aortic valve stenosis who meet the commercially approved indications for TAVR.
Intervention Type
Device
Intervention Name(s)
transShield Embolic Protection System
Intervention Description
Used for embolic protection during TAVR.
Primary Outcome Measure Information:
Title
Safety - Incidence of 30-Day combined rate of the following events directly related to the transShield EPS as defined by VARC-2
Description
Major Adverse Cardiac and Cerebrovascular Events (MACCE)
All cause mortality
All cause stroke (disabling and non-disabling)
Acute kidney injury (Stage 2 or 3)
Major vascular complications
Time Frame
30 day combined rate post-procedure
Title
Performance - Technical Success defined as the transShield EPS ability to perform all the following functions without adjudicated device malfunction
Description
Ability to successfully deploy the device in the correct anatomical position, in the ascending aorta without interference with TAVR procedure/devices
Ability to retrieve and remove the device intact, including no visual evidence of any filter damage
Time Frame
During the procedure
Secondary Outcome Measure Information:
Title
Safety - Incidence of minor vascular complications directly related to the transShield EPS as defined by VARC-2.
Description
As defined by VARC-2.
Incidence of peri-procedural disabling stroke as defined by a modified Rankin Scale (mRS) score of 2 or more at 30 days and an increase in at least one mRS category from an individual's pre-stroke baseline.
Time Frame
30 days post-procedure
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Patients must meet all of the following criteria to be eligible for participation in the study:
Patient is >18 years old
Patient is scheduled for percutaneous TAVR with up to 20French compatible commercial TAVR system
Patient meets indications for TAVR per the device Instructions For Use
The diameter of the artery at the site of the filter placement is between 28 mm and 42 mm
Size and condition of the femoral artery iliac arteries are appropriate for the 12French transShield Expandable Introducer and 20F Embolic Protection Device
Patient, or authorized representative, signs a written Informed Consent form to participate in the study, prior to any study mandated procedures
Patient is willing and able to complete follow-up requirements
Exclusion Criteria:
Patients must be EXCLUDED from participation in this study if any of the following criteria are met:
Patient not undergoing TAVR via the trans-femoral route
Carotid artery stenosis >70% in either carotid artery
Severe vascular tortuosity or anatomy that would preclude the safe introduction of the device
Aortic valve is a congenital unicuspid or congenital bicuspid valve or is non-calcified
Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation >3+)
A known contraindication or hypersensitivity to all anticoagulation regimens or an inability to undergo anticoagulation for the study procedure
History of bleeding diathesis or in whom anticoagulant and/or anti-platelet therapy is contraindicated, patients who will refuse transfusion, or havean active peptic ulcer or upper GI bleeding within the prior 3 months
Renal insufficiency, defined as a creatinine level > 221μmol/L and/or end-stage renal disease requiring chronic dialysis at time of treatment
History of stroke or transient ischemic attack (TIA) within prior 6 months
Evidence of an acute myocardial infarction (MI) within prior 30 days
Hemodynamic or respiratory instability requiring inotropic support, mechanical ventilation, or mechanical heart assistance within prior 30 days
Hypertrophic cardiomyopathy with or without obstruction
Need for emergency surgery for any reason
Severe left ventricular (LV) dysfunction with LV ejection fraction (LVEF) <20%
Severe pulmonary hypertension and right ventricular (RV) dysfunction
Echocardiographic evidence of intracardiac mass, thrombus or vegetation
Life expectancy < 12 months due to non-cardiac co-morbid conditions
Evidence of active systemic or local groin infection
Significant aortic disease, including abdominal aortic or thoracic aneurysm defined as maximal luminal diameter 5cm or greater; marked tortuosity (hyperacute bend), aortic arch atheroma or narrowing (especially with calcification and surface irregularities) of the abdominal or thoracic aorta, severe "unfolding" and tortuosity of the thoracic aorta
Known hypersensitivity or contraindication to aspirin, heparin, ticlopidine, or clopidogrel, or sensitivity to contrast media, that cannot be managed with premedication
Planned other cardiac surgical procedure within 2 weeks prior to, or planned cardiac surgical or interventional procedure within 30 days after the TAVR procedure. Note: Diagnostic cardiac catheterization is permitted within 10 days prior to the TAVR procedure
Neurodegenerative or other progressive neurological disease
Known allergy to any device component
Known or suspected to be pregnant or lactating
Currently enrolled in an investigational drug or device clinical study in which the primary endpoint has not occurred
Patient has other medical, social or psychological problem that in the opinion of the investigator precludes them from participating
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Amy Forro
Phone
(508) 254-1005
Email
aforro@linceconsulting.com
First Name & Middle Initial & Last Name or Official Title & Degree
Sarah Mazhar
Phone
(415) 269-7580
Email
smazhar@linceconsulting.com
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Mark Webster, MD
Organizational Affiliation
Auckland City Hospital
Official's Role
Principal Investigator
First Name & Middle Initial & Last Name & Degree
Carlos Calderas, MD
Organizational Affiliation
Policlinica Metropolitana - Venezuela
Official's Role
Principal Investigator
Facility Information:
Facility Name
Auckland City Hospital
City
Auckland
State/Province
Grafton
ZIP/Postal Code
1142
Country
New Zealand
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Mandy Fish
Phone
00 64) 09 307 4949
Ext
24366
Email
mfish@adhb.govt.nz
First Name & Middle Initial & Last Name & Degree
Mark Webster, MD
Facility Name
Waikato Hospital
City
Hamilton
ZIP/Postal Code
3204
Country
New Zealand
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Amy Forro
Phone
(508) 254-1005
Email
aforro@linceconsulting.com
First Name & Middle Initial & Last Name & Degree
Sarah Mazhar
Phone
4152697580
Email
smazhar@linceconsulting.com
First Name & Middle Initial & Last Name & Degree
Sanjeevan Pasupati, MD
Facility Name
Policlinica Metropolitana, C.A
City
Miranda
State/Province
Caracas
ZIP/Postal Code
1061
Country
Venezuela
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Lenotschka Briceño
Phone
+58 416 629 1814
Email
labgasesoria@gmail.com
First Name & Middle Initial & Last Name & Degree
Carlos Calderas, MD
Phone
+ 58 416 6291814
Email
cdcalderas@gmail.com
First Name & Middle Initial & Last Name & Degree
Carlos Calderas, MD
Facility Name
Ascardio Asociación Cardiovascular Centroccidental
City
La Lara
State/Province
Sector La Feria
ZIP/Postal Code
3002
Country
Venezuela
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Lenotschka Briceño
Phone
+58 414 1105253
Email
labgasesoria@gmail.com
First Name & Middle Initial & Last Name & Degree
Vicente Finizola, MD
Phone
+58 4245030886
Email
vfinizola@gmail.com