search
Back to results

Vortex - Temporary Percutaneous, Transvalvular Circulatory Support System Feasibility Study (Vortex-FIH)

Primary Purpose

Coronary Artery Disease

Status
Completed
Phase
Not Applicable
Locations
International
Study Type
Interventional
Intervention
Temporary Percutaneous Transvalvular Circulatory Support System (Vortex System)
Sponsored by
Boston Scientific Corporation
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional device feasibility trial for Coronary Artery Disease focused on measuring Mechanical circulatory support, High risk percutaneous coronary intervention (HR PCI)

Eligibility Criteria

18 Years - 89 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

A subject will be considered for enrolment in the study if all of the following inclusion criteria are met, provided no exclusion criteria are met:

IC1. Subject provides signed informed consent. IC2. Subject is ≥ 18 years and < 90 years of age.

IC3 Subject is indicated for NON-emergent PCI of at least one de novo or restenotic lesion in a native coronary vessel or coronary artery bypass graft (CABG) and has left ventricular ejection fraction (LVEF) ≤ 50% with the following:

  • Unprotected left main -OR-
  • Last remaining vessel -OR-
  • Three vessel disease (≥ 50% diameter stenoses by visual estimate or total occlusion)

Exclusion Criteria:

A subject will be excluded from the study if any of the following exclusion criteria are met:

EC1. Subject has had ST-elevation myocardial infarction (STEMI) within 24 hours.

EC2. Subject has had pre-procedure cardiac arrest requiring cardiopulmonary resuscitation (CPR) within 24 hours of enrollment.

EC3. Subject is in shock, defined as follows:

  • Cardiac index (CI) < 2.2 L/min/m2 and pulmonary capillary wedge pressure (PCWP) > 15 mmHg -AND-
  • Hypotension (systolic blood pressure < 90 mmHg for > 30 minutes) -OR-
  • Need for supportive measures (i.e., inotropes or mechanical support) to maintain systolic blood pressure ≥ 90 mmHg and end organ hypoperfusion (cool extremities or urine < 30 mL/hour and a heart rate > 60 beats per minute) EC4. Subject has left ventricular mural thrombus. EC5. Subject has a prosthetic aortic valve. EC6. Subject has pericarditis or constrictive heart disease (constrictive pericarditis or restrictive cardiomyopathy).

EC7. Subject has moderate or greater aortic valve stenosis or moderate or greater aortic valve insufficiency (by echocardiographic assessment, graded as ≥ 2+).

EC8. Subject has abnormalities of the aorta that preclude safe delivery of the device, including severe calcification, tortuosity, aneurysm, or prior surgery.

EC9. Subject has peripheral vessel disease (PVD) preventing passage of the device (e.g., calcification, small caliber) or tortuosity that would preclude safe placement of the 16 Fr introducer sheath.

Note: Minimum required vessel diameter is > 5.5 mm. EC10. Subject has advanced renal dysfunction (AKIN Stage 3). EC11. Subject has a history of liver dysfunction (Childs Class C) with elevation of liver enzymes and bilirubin > 3× upper limit of normal (ULN) or international normalization ratio (INR) ≥ 2.

EC12. Subject has had a recent (within 1 month) stroke or TIA. EC13. Subject has known hypersensitivity to intravenous contrast agents that cannot be adequately pre-medicated or has known hypersensitivity to heparin, aspirin, ADP receptor inhibitors or nitinol.

EC14. Subject has current or a history of heparin induced thrombocytopenia (HIT).

EC15. Subject has uncorrected abnormal coagulation or platelet count ≤ 75,000/mm³ or INR ≥ 2.0.

EC16. Subject has significant right heart failure (right atrial pressure [RAP] > 15 mmHg, right ventricular stroke work index [RVSWI] < 0.30 mmHg·L/m², pulmonary vascular resistance [PVR] > 3.6 Woods units).

EC17. Subject requires mechanical ventilation. EC18. Subject has an atrial or ventricular septal defect (including post-infarct ventricular septal defect [VSD]).

EC19. Subject has left ventricular rupture. EC20. Subject has cardiac tamponade. EC21. Subject has severe pulmonary disease (FEV1 < 1L). EC22. Subject has sustained or non-sustained ventricular tachycardia. EC23. Subject is breast feeding or is pregnant.

Sites / Locations

  • The Alfred Hospital
  • Skane University Hospital

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

Vortex Feasibility Study (Vortex FIH)

Arm Description

Vortex - First in Human Study to Evaluate the Feasibility, Safety, Clinical and Technical Success of the Vortex Temporary Percutaneous, Transvalvular Circulatory Support System (Vortex System)

Outcomes

Primary Outcome Measures

Technical success
Successful delivery of the device to the correct anatomical position and successful operation and removal of the Vortex circulatory support system
Clinical success
No conversion to open heart surgery; and no in-hospital mortality

Secondary Outcome Measures

Full Information

First Posted
December 14, 2020
Last Updated
July 19, 2022
Sponsor
Boston Scientific Corporation
search

1. Study Identification

Unique Protocol Identification Number
NCT04674111
Brief Title
Vortex - Temporary Percutaneous, Transvalvular Circulatory Support System Feasibility Study
Acronym
Vortex-FIH
Official Title
Vortex - First in Human Study to Evaluate the Feasibility, Safety, Clinical and Technical Success of the Vortex Temporary Percutaneous, Transvalvular Circulatory Support System (Vortex System)
Study Type
Interventional

2. Study Status

Record Verification Date
July 2022
Overall Recruitment Status
Completed
Study Start Date
September 28, 2021 (Actual)
Primary Completion Date
April 8, 2022 (Actual)
Study Completion Date
April 8, 2022 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Boston Scientific Corporation

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
Vortex - First in Human study to evaluate the feasibility, safety, clinical and technical success of the Vortex temporary percutaneous, transvalvular circulatory support system (Vortex System)

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Coronary Artery Disease
Keywords
Mechanical circulatory support, High risk percutaneous coronary intervention (HR PCI)

7. Study Design

Primary Purpose
Device Feasibility
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Model Description
Prospective, open-label, single-arm feasibility study
Masking
None (Open Label)
Allocation
N/A
Enrollment
5 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Vortex Feasibility Study (Vortex FIH)
Arm Type
Experimental
Arm Description
Vortex - First in Human Study to Evaluate the Feasibility, Safety, Clinical and Technical Success of the Vortex Temporary Percutaneous, Transvalvular Circulatory Support System (Vortex System)
Intervention Type
Device
Intervention Name(s)
Temporary Percutaneous Transvalvular Circulatory Support System (Vortex System)
Intervention Description
The Vortex System is indicated to provide temporary circulatory support in subjects undergoing elective high-risk percutaneous coronary intervention (HR-PCI).
Primary Outcome Measure Information:
Title
Technical success
Description
Successful delivery of the device to the correct anatomical position and successful operation and removal of the Vortex circulatory support system
Time Frame
The Vortex system is indicated to provide temporary (≤ 4 hours) circulatory intended to be used to support in patients undergoing high-risk percutaneous coronary intervention (HR PCI).
Title
Clinical success
Description
No conversion to open heart surgery; and no in-hospital mortality
Time Frame
The Vortex system is indicated to provide temporary (≤ 4 hours) circulatory intended to be used to support in patients undergoing high-risk percutaneous coronary intervention (HR PCI).

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
89 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: A subject will be considered for enrolment in the study if all of the following inclusion criteria are met, provided no exclusion criteria are met: IC1. Subject provides signed informed consent. IC2. Subject is ≥ 18 years and < 90 years of age. IC3 Subject is indicated for NON-emergent PCI of at least one de novo or restenotic lesion in a native coronary vessel or coronary artery bypass graft (CABG) and has left ventricular ejection fraction (LVEF) ≤ 50% with the following: Unprotected left main -OR- Last remaining vessel -OR- Three vessel disease (≥ 50% diameter stenoses by visual estimate or total occlusion) Exclusion Criteria: A subject will be excluded from the study if any of the following exclusion criteria are met: EC1. Subject has had ST-elevation myocardial infarction (STEMI) within 24 hours. EC2. Subject has had pre-procedure cardiac arrest requiring cardiopulmonary resuscitation (CPR) within 24 hours of enrollment. EC3. Subject is in shock, defined as follows: Cardiac index (CI) < 2.2 L/min/m2 and pulmonary capillary wedge pressure (PCWP) > 15 mmHg -AND- Hypotension (systolic blood pressure < 90 mmHg for > 30 minutes) -OR- Need for supportive measures (i.e., inotropes or mechanical support) to maintain systolic blood pressure ≥ 90 mmHg and end organ hypoperfusion (cool extremities or urine < 30 mL/hour and a heart rate > 60 beats per minute) EC4. Subject has left ventricular mural thrombus. EC5. Subject has a prosthetic aortic valve. EC6. Subject has pericarditis or constrictive heart disease (constrictive pericarditis or restrictive cardiomyopathy). EC7. Subject has moderate or greater aortic valve stenosis or moderate or greater aortic valve insufficiency (by echocardiographic assessment, graded as ≥ 2+). EC8. Subject has abnormalities of the aorta that preclude safe delivery of the device, including severe calcification, tortuosity, aneurysm, or prior surgery. EC9. Subject has peripheral vessel disease (PVD) preventing passage of the device (e.g., calcification, small caliber) or tortuosity that would preclude safe placement of the 16 Fr introducer sheath. Note: Minimum required vessel diameter is > 5.5 mm. EC10. Subject has advanced renal dysfunction (AKIN Stage 3). EC11. Subject has a history of liver dysfunction (Childs Class C) with elevation of liver enzymes and bilirubin > 3× upper limit of normal (ULN) or international normalization ratio (INR) ≥ 2. EC12. Subject has had a recent (within 1 month) stroke or TIA. EC13. Subject has known hypersensitivity to intravenous contrast agents that cannot be adequately pre-medicated or has known hypersensitivity to heparin, aspirin, ADP receptor inhibitors or nitinol. EC14. Subject has current or a history of heparin induced thrombocytopenia (HIT). EC15. Subject has uncorrected abnormal coagulation or platelet count ≤ 75,000/mm³ or INR ≥ 2.0. EC16. Subject has significant right heart failure (right atrial pressure [RAP] > 15 mmHg, right ventricular stroke work index [RVSWI] < 0.30 mmHg·L/m², pulmonary vascular resistance [PVR] > 3.6 Woods units). EC17. Subject requires mechanical ventilation. EC18. Subject has an atrial or ventricular septal defect (including post-infarct ventricular septal defect [VSD]). EC19. Subject has left ventricular rupture. EC20. Subject has cardiac tamponade. EC21. Subject has severe pulmonary disease (FEV1 < 1L). EC22. Subject has sustained or non-sustained ventricular tachycardia. EC23. Subject is breast feeding or is pregnant.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Prof. Antony Walton, MBBS
Organizational Affiliation
The Alfred
Official's Role
Principal Investigator
Facility Information:
Facility Name
The Alfred Hospital
City
Melbourne
State/Province
Victoria
ZIP/Postal Code
3004
Country
Australia
Facility Name
Skane University Hospital
City
Lund
ZIP/Postal Code
222-42
Country
Sweden

12. IPD Sharing Statement

Plan to Share IPD
No

Learn more about this trial

Vortex - Temporary Percutaneous, Transvalvular Circulatory Support System Feasibility Study

We'll reach out to this number within 24 hrs