Comparison of CoCr Alloy and TiN Coating in TKA
Primary Purpose
Osteoarthritis, Knee, Arthroplasty, Replacement, Knee
Status
Withdrawn
Phase
Not Applicable
Locations
Austria
Study Type
Interventional
Intervention
TiN-alloy based total knee arthroplasty
CoCr-coating based total knee arthroplasty
Sponsored by
About this trial
This is an interventional treatment trial for Osteoarthritis, Knee focused on measuring Implant coating/alloy, Titanium-Nitride (TiN) coating, Cobalt-Chromium (CoCr) alloy
Eligibility Criteria
Inclusion Criteria:
- Knee osteoarthritis of index knee
- Varus angle < 15° of index knee
Exclusion Criteria:
- Previous native knee infection of index knee
- Previous distal femoral fracture of index knee
- Previous proximal tibial fracture of index knee
- Preceding osteotomy of index knee
- Known allergies against metals, drugs, organic substances
- Unicondylar prosthetic replacement of index knee
- Knee osteoarthritis of both joints with planned simultaneous TKA
Sites / Locations
- Department of Orthopaedics and Trauma, Medical University of Graz, Austria
Arms of the Study
Arm 1
Arm 2
Arm Type
Experimental
Active Comparator
Arm Label
Group A (TiN-coating)
Group B (CoCr-alloy)
Arm Description
Patients with knee osteoarthritis receive total knee arthroplasty with Titanium-Nitride (TiN)-coated implant.
Patients with knee osteoarthritis receive total knee arthroplasty with Cobalt-Chromium (CoCr)-alloy implant.
Outcomes
Primary Outcome Measures
Change of Postoperative functional outcome - ROM with goniometer
Range of motion (ROM), assessed with goniometer approved for medical issues
Change of Postoperative functional outcome - pain
VAS score (Visual Analogue Scale; 0 = no pain, 10 = severe pain)
Change of Postoperative functional outcome - Western Ontario and McMaster Universities Arthritis Index (WOMAC)
Assessed by Western Ontario and McMaster Universities Arthritis Index (WOMAC). This index ranges from 0 to 100 points and is based on items pain, physical function and joint stiffness. Lower values indicating better outcomes, whilst higher values point towards worse outcome.
Higher scores on the WOMAC indicate a worse outcome
Change of Postoperative functional outcome - FJS
Forgotten Joint Score (FJS) with a scale ranging from 0 to 100, where a high value indicates a better outcome
Change of Postoperative functional outcome - Knee Society Score (KSS)
Knee society score (KSS) is built up by two scores, i.e. "Functional Score" (3 items) and "Knee Score" (7 items), both ranging from 0 to 100 points. The lower the values, the worse the outcome.
Secondary Outcome Measures
Change of Metal ion levels in blood stream
Measurement of titanium, cobalt, chromium, molybdenum in blood stream at specific time-points.
Full Information
NCT ID
NCT04701359
First Posted
October 30, 2020
Last Updated
March 14, 2023
Sponsor
Medical University of Graz
Collaborators
Alphamed Medizintechnik Fischer GmbH
1. Study Identification
Unique Protocol Identification Number
NCT04701359
Brief Title
Comparison of CoCr Alloy and TiN Coating in TKA
Official Title
Comparison of Cobalt-Chromium (CoCr) Alloy and Titanium-Nitride (TiN) Coating in Total Knee Arthroplasty: A Prospective, Randomised, Double-blinded Clinical Trial
Study Type
Interventional
2. Study Status
Record Verification Date
March 2023
Overall Recruitment Status
Withdrawn
Why Stopped
Implant to be analysed not used at study centre any more.
Study Start Date
October 10, 2022 (Anticipated)
Primary Completion Date
November 1, 2024 (Anticipated)
Study Completion Date
November 1, 2029 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Medical University of Graz
Collaborators
Alphamed Medizintechnik Fischer GmbH
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No
5. Study Description
Brief Summary
In the current prospective, randomized study, two different materials of the same total knee arthroplasty (TKA) system - cobalt-chromium (CoCr) and titanium-nitride (TiN) - are going to be compared with regards to postoperative outcome. Two-hundred patients are planned to be included in the study over a 4-year period, randomly assigned to either the CoCr- or TiN-implant-group. In order to ensure double-blinding, patients will not be informed about the group they had been assigned to. Moreover, no identifying information of the implant used will be written on documents later accessible to nurses and/or physicians at follow-up appointments. Consequently, surgeons of the respective patients will be excluded from study-specific examination of patients. Despite range of motion (ROM), questionnaires (visual analogue scale - VAS; Western Ontario and McMaster Universities Osteoarthritis Index - WOMAC, Forgotten Joint Score - FJS; Knee Society Scoe - KSS) will be used to assess the postoperative outcome. Furthermore, metal ion levels (cobalt, chrom, molybdenum, titanium) in the blood stream of patients will be measured at scheduled follow-up appointments. It is expected that there will not be a measureable difference between the two coating-groups with regards to ROM, functionality, and metal-ion levels over time.
Detailed Description
Rationale
The present double-blinded study was planned in order to assess whether differences in materials - using one otherwise similar TKA system - would have an effect on postoperative patient outcome. Moreover, metal ion levels will be measured in the blood stream preoperatively (as reference) and upon follow-up, based on previous observations that metal ion levels are increased in serum following TKA, without any relevant influence on outcome.
Aims
The aim of the present prospective study is to assess whether differences in tribological pairings - i.e. TiN-coating in comparison to CoCr-alloy using a frequently implanted total knee endoprosthesis (ACS® System, Implantcast GmbH, Buxtehude, Germany) - have an effect on postoperative range of motion (ROM) and patient satisfaction, reflected by Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Forgotten Joint Score (FJS), Knee Society Score (KSS), Visual Analogue Scale (VAS). Moreover, metal ion levels will be tested in both groups to monitor their concentration in the blood stream, usually reflecting physiological abrasion.
Endpoints
The primary endpoint of the current study is the functional outcome of patients with TKA on a CoCrMo- basis in comparison to a TiN-coated implant. The secondary endpoint is the measurement of metal ion levels in the blood stream and their potential dynamics over time.
Methods
Two-hundred patients will be prospectively included in the study over a 4-year period, with 100 being randomly assigned to group A (TiN-coating) and 100 to group B (CoCr-alloy).
Random assignment will be carried out via an automatic randomisation system run by a local study nurse. Pre- and postoperatively, range of motion (ROM), visual analogue scale (VAS) score and specific questionnaires - i.e. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Forgotten Joint Score (FJS), Knee Society Score (KSS) - will be ascertained (Table 1) in order to allow comparison of potential differences between group A and B during follow-up. Furthermore, preoperatively, at 6 months, 12 months, 24 months and 60 months, metal ion levels (cobalt, chromium, molybdenum, titanium) in the blood stream will be measured in each patient (6ml tubes). Measurements of metal ion levels will be performed at an external institution.
The phase of active recruiting is planned for 4 years, with 50 patients being included per year on average. With the last patients anticipated to being included at the end of the 4th year, their follow-up will be finished 9 years after study initiation.
Randomisation and Blinding
All patients will be informed prior to potential study participation whether or not to they would like to participate, clarifying that refusal will not have any negative impact on further treatment. In case patients agree to participate, they will be randomly assigned to either group A or B.
Double-blinding will be made possible by not informing patients whether they had been allocated to group A or B and by not directly revealing information about the implant type used on medical records that will later be accessible to the study nurse and/or physicians during clinical examinations at follow- up. Therefore, it will be necessary to exclude those surgeons participating in the surgeries of the respective patients from examining them during follow-up, in order to maintain blinding. Prior to follow-up appointments, surgeons who had not participated in surgeries of the respective patients will thus be informed by the study nurse in order to perform clinical examination, radiological follow-up and questionnaires.
Expected Results
As patients receive the identical orthopaedic implant during an identical surgical procedure for comparable indications, it is expected that the differences in alloy (i.e. TiN vs. CoCr) will not have a measurable effect on postoperative patient outcome. Neither there is expected to be a difference in metal ion levels in the blood stream over time between groups.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Osteoarthritis, Knee, Arthroplasty, Replacement, Knee
Keywords
Implant coating/alloy, Titanium-Nitride (TiN) coating, Cobalt-Chromium (CoCr) alloy
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Model Description
Two-hundred patients with knee osteoarthritis included altogether. Patients randomly assigned to group A (receiving total knee arthroplasty [TKA] with TiN-coating) or group B (receiving TKA with CoCr-alloy).
Masking
ParticipantOutcomes Assessor
Masking Description
Masking of both patients and outcome assessors. Only care provider (i.e. surgeon) and investigator aware of implant-type used. During follow-up, neither care provider nor investigator allowed to assess patients' study-specific outcome. As implants look identical on X-rays, allocation to one or another group cannot be verified by independent outcome assessors.
Allocation
Randomized
Enrollment
0 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Group A (TiN-coating)
Arm Type
Experimental
Arm Description
Patients with knee osteoarthritis receive total knee arthroplasty with Titanium-Nitride (TiN)-coated implant.
Arm Title
Group B (CoCr-alloy)
Arm Type
Active Comparator
Arm Description
Patients with knee osteoarthritis receive total knee arthroplasty with Cobalt-Chromium (CoCr)-alloy implant.
Intervention Type
Device
Intervention Name(s)
TiN-alloy based total knee arthroplasty
Other Intervention Name(s)
ACS System, Implantcast GmbH, Buxtehude, Germany
Intervention Description
TiN-alloy based TKA implanted for knee osteoarthritis.
Intervention Type
Device
Intervention Name(s)
CoCr-coating based total knee arthroplasty
Other Intervention Name(s)
ACS System, Implantcast GmbH, Buxtehude, Germany
Intervention Description
CoCr-coating based TKA implanted for knee osteoarthritis.
Primary Outcome Measure Information:
Title
Change of Postoperative functional outcome - ROM with goniometer
Description
Range of motion (ROM), assessed with goniometer approved for medical issues
Time Frame
Preoperatively, postoperative week 6, month 12, month 24, month 60.
Title
Change of Postoperative functional outcome - pain
Description
VAS score (Visual Analogue Scale; 0 = no pain, 10 = severe pain)
Time Frame
Preoperatively, postoperative week 6, month 12, month 24, month 60.
Title
Change of Postoperative functional outcome - Western Ontario and McMaster Universities Arthritis Index (WOMAC)
Description
Assessed by Western Ontario and McMaster Universities Arthritis Index (WOMAC). This index ranges from 0 to 100 points and is based on items pain, physical function and joint stiffness. Lower values indicating better outcomes, whilst higher values point towards worse outcome.
Higher scores on the WOMAC indicate a worse outcome
Time Frame
Preoperatively, postoperative week 6, month 12, month 24, month 60.
Title
Change of Postoperative functional outcome - FJS
Description
Forgotten Joint Score (FJS) with a scale ranging from 0 to 100, where a high value indicates a better outcome
Time Frame
Preoperatively, postoperative week 6, month 12, month 24, month 60.
Title
Change of Postoperative functional outcome - Knee Society Score (KSS)
Description
Knee society score (KSS) is built up by two scores, i.e. "Functional Score" (3 items) and "Knee Score" (7 items), both ranging from 0 to 100 points. The lower the values, the worse the outcome.
Time Frame
Preoperatively, postoperative week 6, month 12, month 24, month 60.
Secondary Outcome Measure Information:
Title
Change of Metal ion levels in blood stream
Description
Measurement of titanium, cobalt, chromium, molybdenum in blood stream at specific time-points.
Time Frame
Preoperatively, month 6, month 12, month 24, month 60.
10. Eligibility
Sex
All
Minimum Age & Unit of Time
50 Years
Maximum Age & Unit of Time
90 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Knee osteoarthritis of index knee
Varus angle < 15° of index knee
Exclusion Criteria:
Previous native knee infection of index knee
Previous distal femoral fracture of index knee
Previous proximal tibial fracture of index knee
Preceding osteotomy of index knee
Known allergies against metals, drugs, organic substances
Unicondylar prosthetic replacement of index knee
Knee osteoarthritis of both joints with planned simultaneous TKA
Facility Information:
Facility Name
Department of Orthopaedics and Trauma, Medical University of Graz, Austria
City
Graz
ZIP/Postal Code
8036
Country
Austria
12. IPD Sharing Statement
Plan to Share IPD
No
IPD Sharing Plan Description
It is not planned to share the IPD in full. However, results of the study are planned to be made public within a scientific work.
Citations:
PubMed Identifier
28528349
Citation
Fabry C, Zietz C, Baumann A, Ehall R, Bader R. High wear resistance of femoral components coated with titanium nitride: a retrieval analysis. Knee Surg Sports Traumatol Arthrosc. 2018 Sep;26(9):2630-2639. doi: 10.1007/s00167-017-4578-7. Epub 2017 May 20.
Results Reference
background
PubMed Identifier
24774225
Citation
Fennema P, Heyse TJ, Uyl-de Groot CA. Cost-effectiveness and clinical implications of advanced bearings in total knee arthroplasty: a long-term modeling analysis. Int J Technol Assess Health Care. 2014 Apr;30(2):218-25. doi: 10.1017/S0266462314000129. Epub 2014 Apr 28.
Results Reference
background
PubMed Identifier
24951734
Citation
Gudnason A, Hailer NP, W-Dahl A, Sundberg M, Robertsson O. All-Polyethylene Versus Metal-Backed Tibial Components-An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register. J Bone Joint Surg Am. 2014 Jun 18;96(12):994-999. doi: 10.2106/JBJS.M.00373.
Results Reference
background
PubMed Identifier
26584076
Citation
Lapaj L, Wendland J, Markuszewski J, Mroz A, Wisniewski T. Retrieval analysis of titanium nitride (TiN) coated prosthetic femoral heads articulating with polyethylene. J Mech Behav Biomed Mater. 2015 Mar;55:127-139. doi: 10.1016/j.jmbbm.2015.10.012. Epub 2015 Oct 30.
Results Reference
background
PubMed Identifier
27209191
Citation
Longo UG, Ciuffreda M, D'Andrea V, Mannering N, Locher J, Denaro V. All-polyethylene versus metal-backed tibial component in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2017 Nov;25(11):3620-3636. doi: 10.1007/s00167-016-4168-0. Epub 2016 May 21.
Results Reference
background
PubMed Identifier
25567357
Citation
Paxton EW, Inacio MC, Kurtz S, Love R, Cafri G, Namba RS. Is there a difference in total knee arthroplasty risk of revision in highly crosslinked versus conventional polyethylene? Clin Orthop Relat Res. 2015 Mar;473(3):999-1008. doi: 10.1007/s11999-014-4046-3.
Results Reference
background
PubMed Identifier
29616285
Citation
Postler A, Beyer F, Lutzner C, Tille E, Lutzner J. Similar outcome during short-term follow-up after coated and uncoated total knee arthroplasty: a randomized controlled study. Knee Surg Sports Traumatol Arthrosc. 2018 Nov;26(11):3459-3467. doi: 10.1007/s00167-018-4928-0. Epub 2018 Apr 3.
Results Reference
background
Learn more about this trial
Comparison of CoCr Alloy and TiN Coating in TKA
We'll reach out to this number within 24 hrs