Post-market Clinical Investigation of the SING IMT System, Model NG SI IMT 3X in Patients With End-stage Age-related Macular Degeneration

Primary Purpose

AMD, Age-Related Macular Degeneration

Status
Recruiting
Phase
Not Applicable
Locations
International
Study Type
Interventional
Intervention
SING IMT(TM) System, model NG SI IMT 3X
Sponsored by
VisionCare, Inc.
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional other trial for AMD focused on measuring Age Related Macular Degeneration, Dry AMD, End-stage age-related macular degeneration, Central vision impairment, Geographic atrophy

Eligibility Criteria

55 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. Be 55 years of age or older.
  2. Have retinal findings of geographic atrophy or disciform scar with foveal involvement as determined by fluorescein angiography.
  3. Have evidence of cataract.
  4. Have BCDVA no better than 20/80 and no worse than 20/800 in both eyes.
  5. Have adequate peripheral vision in the eye not scheduled for surgery.
  6. Achieve at least a five-letter improvement on the ETDRS chart in the eye scheduled for surgery when using VisionCare's 3X ETS (supplied separately).
  7. Have an ACD of at least 2.5 mm in the eye scheduled for surgery.
  8. Be willing to participate in a post-operative training program for the use of the NG SI IMT 3X implant.
  9. Review and sign the Independent Ethics Committee (IEC)-approved Informed Consent Form (ICF) prior to any study-related procedures being performed.
  10. Have adequate understanding of the local language to understand verbal and written subject information and be willing to comply with the study requirements.

Exclusion Criteria:

  1. Evidence of active CNV on fluorescein angiography or were treated for CNV within the past six months.
  2. Any ophthalmic pathology that compromises the patient's peripheral vision in the fellow eye.
  3. A history of steroid-responsive rise in IOP, uncontrolled glaucoma, or preoperative IOP>22 mm Hg.
  4. Corneal guttata.
  5. Known sensitivity to post-operative medications.
  6. Significant communication impairment or severe neurological disorders.
  7. Have undergone previous intraocular or corneal surgery of any kind in the operative eye, including any type of surgery for either refractive or therapeutic purposes.
  8. An ocular condition that predisposes the patient to eye rubbing.
  9. Prior or expected ophthalmic-related surgery within 30 days preceding the NG SI IMT 3X implant surgery.
  10. Patients for whom the planned operative eye has:

    • Myopia > 6.0 D
    • Hyperopia > 4.0 D
    • Axial length < 21 mm
    • Endothelial cell density < 1600 cells per square mm
    • Narrow angle, i.e., < Schaffer grade 2.
  11. Inflammatory ocular disease.
  12. Cornea stromal or endothelial dystrophies, including guttata.
  13. Zonular weakness/instability of crystalline lens, or pseudoexfoliation.
  14. Diabetic retinopathy.
  15. Untreated retinal tears.
  16. Retinal vascular disease.
  17. Optic nerve disease.
  18. A history of retinal detachment.
  19. Retinitis pigmentosa.
  20. Intraocular tumor.
  21. Have received any investigational product within 30 days prior to study enrollment or be planning to participate in another investigation during the course of this study.
  22. Be an employee (or a relative of an employee) of the contract research organization (CRO) responsible for conducting the study, Sponsor, or Sponsor representative.
  23. Have a condition or be in a situation that, in the Investigator's opinion, may put the Subject at significant risk, may confound the study results, or may interfere significantly with the Subject's participation in the study.

Sites / Locations

  • Augenklinik Städtisches Klinikum Karlsruhe
  • Universitätsklinikum Münster Klinik für Augenheilkunde
  • Mater Misericordiae University HospitalRecruiting
  • Università degli Studi di Napoli Federico II
  • Fondazione Policlinico Universitario Agostino GemelliRecruiting
  • VISSUMRecruiting
  • Institut OMIQRecruiting
  • Royal Victoria Hospital Belfast Health & Social Care Trust

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

SING IMT System model NG SI IMT 3X

Arm Description

All participants will be implanted with the SING IMT System model NG SI IMT 3X.

Outcomes

Primary Outcome Measures

Safety of the SING IMT System, model NG SI IMT 3X, including its delivery system
The percent decrease in endothelial cell density (ECD).

Secondary Outcome Measures

Incision size needed for device implantation
Incision size will not exceed 8.0 mm (non-inferiority assumption) in 75% of surgeries
Surgical complications
AEs and serious adverse events
Improvement in near and distance best corrected visual acuity (BCVA) in implanted eyes.
Near and distance BCVA will show an improvement of ≥2 lines in the ETDRS chart in at least 50% (non-inferior to 50%) of the implanted eyes at 12 months post implantation.
Usability of SING IMT System, including delivery system
Surgeon will complete a usability and satisfaction questionnaire

Full Information

First Posted
March 3, 2021
Last Updated
July 25, 2023
Sponsor
VisionCare, Inc.
search

1. Study Identification

Unique Protocol Identification Number
NCT04796545
Brief Title
Post-market Clinical Investigation of the SING IMT System, Model NG SI IMT 3X in Patients With End-stage Age-related Macular Degeneration
Official Title
A Prospective, Multicenter Post-marketing Clinical Investigation of the SING IMT(TM) System, Model NG SI IMT 3X in Patients With Central Vision Impairment Associated With End-stage Age-related Macular Degeneration
Study Type
Interventional

2. Study Status

Record Verification Date
July 2023
Overall Recruitment Status
Recruiting
Study Start Date
September 13, 2022 (Actual)
Primary Completion Date
February 2027 (Anticipated)
Study Completion Date
December 2028 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
VisionCare, Inc.

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
The objective of this study is to demonstrate the safety and effectiveness of the SING IMT (Smaller Incision New Generation Implantable Miniature Telescope) 3X implant in improving vision in patients with central vision impairment associated with end-stage Age-related Macular Degeneration (AMD). Eligible patients will be implanted with the SING IMT device and will be followed-up for a period of 12-months with post-operative ophthalmic exams and low-vision rehabilitation sessions.
Detailed Description
This is an interventional, prospective, multicenter, open label, single group assignment Post-Market Clinical Follow-up (PMCF) study in men and women >=55 years with central vision impairment associated with end-stage AMD. Following completion of informed consent, patients will be evaluated for eligibility to enroll into the study. Baseline visual acuity of the study subjects will be assessed with a 2.8X external telescope simulator (ETS) using Early Treatment Diabetic Retinopathy Study (ETDRS) charts to determine if they are likely to benefit from receiving the IMT. To be included in the study and to proceed with the surgery, subjects must achieve, using the ETS, at least a one line (5 or more letters) improvement in distance on the ETDRS chart in the eye scheduled for surgery. Subjects not meeting these criteria will be excluded from the study. If eligible, they will be scheduled for out-patient surgery to implant the IMT during routine cataract surgery. Postoperatively, the surgeon will complete a usability and satisfaction questionnaire after each implantation procedure. The patients will undergo ophthalmic evaluations in both eyes at regular intervals for up to 12 months. The subjects will also be required to undergo 6 to 10 additional visits for vision training with a low vision specialist. Surgical complications, as well as all Adverse Event (AEs) and use of medications will be monitored from baseline to the end of the study.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
AMD, Age-Related Macular Degeneration
Keywords
Age Related Macular Degeneration, Dry AMD, End-stage age-related macular degeneration, Central vision impairment, Geographic atrophy

7. Study Design

Primary Purpose
Other
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Model Description
SING IMT(TM) System, model NG SI IMT 3X
Masking
None (Open Label)
Allocation
N/A
Enrollment
76 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
SING IMT System model NG SI IMT 3X
Arm Type
Experimental
Arm Description
All participants will be implanted with the SING IMT System model NG SI IMT 3X.
Intervention Type
Device
Intervention Name(s)
SING IMT(TM) System, model NG SI IMT 3X
Intervention Description
The SING IMT 3X implant is a visual prosthetic implantable device, which, when combined with the optics of the cornea, constitutes a telephoto system for improvement of visual acuity in patients with bilateral, end-stage age-related macular degeneration.
Primary Outcome Measure Information:
Title
Safety of the SING IMT System, model NG SI IMT 3X, including its delivery system
Description
The percent decrease in endothelial cell density (ECD).
Time Frame
12 months
Secondary Outcome Measure Information:
Title
Incision size needed for device implantation
Description
Incision size will not exceed 8.0 mm (non-inferiority assumption) in 75% of surgeries
Time Frame
12 moths
Title
Surgical complications
Description
AEs and serious adverse events
Time Frame
12 moths
Title
Improvement in near and distance best corrected visual acuity (BCVA) in implanted eyes.
Description
Near and distance BCVA will show an improvement of ≥2 lines in the ETDRS chart in at least 50% (non-inferior to 50%) of the implanted eyes at 12 months post implantation.
Time Frame
12 months
Title
Usability of SING IMT System, including delivery system
Description
Surgeon will complete a usability and satisfaction questionnaire
Time Frame
12 months
Other Pre-specified Outcome Measures:
Title
Device stability and fixation
Description
Assessed by slit lamp biomicroscopy examination: device tilt and device decentration
Time Frame
12 months
Title
Post-operative anterior chamber depth (ACD)
Description
Anterior Chamber Depth (ACD) evaluated by ultrasound biomicroscopy (UBM), ocular coherence tomography (OCT) or another applicable test method
Time Frame
12 months

10. Eligibility

Sex
All
Minimum Age & Unit of Time
55 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Be 55 years of age or older. Have retinal findings of geographic atrophy or disciform scar with foveal involvement as determined by fluorescein angiography or OCT. Have evidence of cataract. Have best-corrected distance visual acuity (BCDVA) no better than 20/80 (0.6 LogMAR) and no worse than 20/800 (1.6 LogMAR) in both eyes. Have adequate peripheral vision in the eye not scheduled for surgery, assessed by observation of ambulation. Achieve at least a five-letter improvement on the ETDRS chart in the eye scheduled for surgery when using Samsara's 2.8X external telescope simulator (ETS, supplied separately). Have an ACD of at least 2.5 mm in the eye scheduled for surgery. Be willing to participate in a post-operative training program for the use of the NG SI IMT 3X implant. Review and sign the Independent Ethics Committee (IEC)-approved Informed Consent Form (ICF) prior to any study-related procedures being performed. Have adequate understanding of the local language to understand verbal and written subject information and be willing to comply with the study requirements. Exclusion Criteria: Evidence of active choroidal neovascularization (CNV) on fluorescein angiography or OCT or were treated for CNV within the past six months. Any ophthalmic pathology that compromises the patient's peripheral vision in the fellow eye. A history of steroid-responsive rise in IOP, uncontrolled glaucoma, or preoperative IOP>22 mm Hg. Corneal guttata. Known sensitivity to post-operative medications. Significant communication impairment or severe neurological disorders. Have undergone previous intraocular or corneal surgery of any kind in the operative eye, including any type of surgery for either refractive or therapeutic purposes. An ocular condition that predisposes the patient to eye rubbing. Prior or expected ophthalmic-related surgery within 30 days preceding the NG SI IMT 3X implant surgery. Patients for whom the planned operative eye has: Myopia > 6.0 D Hyperopia > 4.0 D Axial length < 21 mm Endothelial cell density < 1600 cells per square mm Narrow angle, i.e., < Schaffer grade 2. Inflammatory ocular disease. Cornea stromal or endothelial dystrophies, including guttata. Zonular weakness/instability of crystalline lens, or pseudoexfoliation. Diabetic retinopathy. Untreated retinal tears. Retinal vascular disease. Optic nerve disease. A history of retinal detachment. Retinitis pigmentosa. Intraocular tumor. Have received any investigational product within 30 days prior to study enrollment or be planning to participate in another investigation during the course of this study. Be an employee (or a relative of an employee) of the contract research organization (CRO) responsible for conducting the study, Sponsor, or Sponsor representative. Have a condition or be in a situation that, in the Investigator's opinion, may put the Subject at significant risk, may confound the study results, or may interfere significantly with the Subject's participation in the study.
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Anne Roller, PhD
Phone
+ 33 (0)3 88 30 88 11
Email
clinicals@medevise-consulting.com
Facility Information:
Facility Name
Augenklinik Städtisches Klinikum Karlsruhe
City
Karlsruhe
Country
Germany
Individual Site Status
Terminated
Facility Name
Universitätsklinikum Münster Klinik für Augenheilkunde
City
Münster
Country
Germany
Individual Site Status
Active, not recruiting
Facility Name
Mater Misericordiae University Hospital
City
Dublin
Country
Ireland
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
David Keegan, MD
Facility Name
Università degli Studi di Napoli Federico II
City
Napoli
Country
Italy
Individual Site Status
Not yet recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Mario Toro, MD
Facility Name
Fondazione Policlinico Universitario Agostino Gemelli
City
Roma
Country
Italy
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Stanislao Rizzo, MD
Facility Name
VISSUM
City
Alicante
Country
Spain
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Jorge Alio, MD
Facility Name
Institut OMIQ
City
Barcelona
Country
Spain
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Merce Guarro, MD
Facility Name
Royal Victoria Hospital Belfast Health & Social Care Trust
City
Belfast
Country
United Kingdom
Individual Site Status
Not yet recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Guiliana Silvestri, MD

12. IPD Sharing Statement

Plan to Share IPD