PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Spain (PHY2103)

Primary Purpose

Cataract, Lens Opacities, Astigmatism

Status
Active
Phase
Not Applicable
Locations
Spain
Study Type
Interventional
Intervention
IOL implantation experimental
Sponsored by
Beaver-Visitec International, Inc.
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Cataract focused on measuring Intraocular Lens, Monofocal, Toric Lens

Eligibility Criteria

50 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Male or female adults ages 50 years or older on the day of screening who have clinically documented cataracts in both eyes;
  • Calculated IOL power (sphere and cylinder) is within the range of the investigational IOLs;
  • Regular corneal astigmatism (measured by a topographer);
  • Corneal astigmatism ≥0.75 D and ≤ 4.25 D (measured by an automatic keratometer) in one or both eyes;
  • Capability to understand and sign an IRB approved informed consent form and privacy authorization;
  • Clear intraocular media other than cataract;
  • Dilated pupil size large enough to visualize IOL axis markings postoperatively;
  • Best corrected visual acuity projected to be better than 0.2 logMAR after toric IOL implantation;
  • Willing and able to conform to the study requirements.

Exclusion Criteria:

  • Age of patient <50 years at the day of screening;
  • Regular corneal astigmatism <0.75 D or >4.25 D (measured by an automatic keratometer) in both eyes
  • Irregular astigmatism (measured by a topographer);
  • Subjects with diagnosed degenerative visual disorders (e.g. macular degeneration or other retinal or optic disorders);
  • Subjects with AMD suspicious eyes as determined by OCT examination;
  • Previous intraocular or corneal surgery;
  • Traumatic cataract;
  • Clinically significant, uncontrolled glaucoma with expected negative impact on Contrast Sensitivity and/or visual acuity outcomes;
  • Instability of keratometry or biometry measurements; Acceptable maximum standard deviation: AL: ± 150 µm; ACD: ± 150 µm; K1 / K2: ± 0.15 D;
  • Ocular hypertension, suspicious glaucoma or glaucoma;
  • Pregnant, lactating or, if able to bear children, unwilling to use medically acceptable birth control over the course of the study;
  • Concurrent or previous (within 30 days) participation in another drug or device investigation;
  • Clinically significant dry eye as determined by the investigator's judgement;
  • Ocular surface disease (clinical symptoms or keratitis);
  • Patients showing contraindications as listed in the current Instructions for use (IFU);
  • Unsuitable for study participation for any other reason, as determined by Investigator's clinical judgment (reason to be documented on eCRF).

In addition to above mentioned in- and exclusion criteria, subjects shall be discontinued when certain conditions are present at the time of surgery, including:

  • zonular instability;
  • need for iris manipulation;
  • capsular fibrosis or other opacity; and
  • inability to fixate IOL in desired position. In such cases, the subject shall be followed until the condition has stabilized.

Sites / Locations

  • Oftalvist Alicante
  • Miranza IMO Barcelona
  • Miranza IOA Madrid
  • Oftalvist Juan Bravo
  • Miranza Virgen de Luján
  • Oftalvist Valencia

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

PODEYE TORIC IOL Implantation experimental

Arm Description

Mono- or bilateral implantation of toric intraocular lenses PODEYE TORIC

Outcomes

Primary Outcome Measures

Rotational stability - Photograph of IOL with dilated pupil to asses IOL rotation
The primary performance endpoint is to show statistically non-inferior rotational stability outcomes on PODEYE TORIC lens compared to CER data obtained for a multifocal toric IOL (POD FT) by the same manufacturer sharing the same haptic design but based on a hydrophilic lens material. The null hypothesis is that the absolute mean IOL rotation measured on PODEYE TORIC is not larger than the absolute mean IOL rotation reported in the current CER on POD FT lens. The alternative hypothesis is that the absolute mean IOL rotation measured on PODEYE TORIC is larger than the outcomes reported in the current CER on POD FT lens. The measure is taken at 6 months postoperative visit compared to the measurement performed within 10 minutes after surgery.

Secondary Outcome Measures

Best Corrected Distance Visual Acuity compared to historical Data
The objective is to compare CDVA above defined thresholds of the investigational product to the results of historical data of EN ISO 11979-7:2018, Annex E (Table E.3 and E.4). The null hypothesis for the CDVA is that / when the true rate of cases with visual acuity 0.3 logMAR or better is less than or equal to the SPE rate. The alternative hypothesis is that the "success" rate is higher than the SPE rate. If the distance corrected visual acuity is 0.3 logMAR or better in 30 eyes or more (with 36 eyes included), the null hypothesis could be rejected, and the alternative hypothesis could be accepted.
Change in cylindrical Power of the Eye
Change in cylindrical power, defined as the difference between magnitude of preoperative keratometric cylinder and postoperative manifest cylinder is calculated at every Form. The outcomes of this calculation will be stratified per 0.25D step of preoperative keratometric cylinder and descriptive statistics (mean, standard deviation, median, minimum, maximum) will be provided.

Full Information

First Posted
April 26, 2021
Last Updated
September 29, 2023
Sponsor
Beaver-Visitec International, Inc.
Collaborators
targomedGmbH
search

1. Study Identification

Unique Protocol Identification Number
NCT04866719
Brief Title
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Spain
Acronym
PHY2103
Official Title
Multicentric Post-market Clinical Follow-Up (PMCF) Study to Investigate Rotational Stability, Clinical Outcomes and Patient Reported Outcomes After Implantation of a Monofocal Toric IOL
Study Type
Interventional

2. Study Status

Record Verification Date
September 2023
Overall Recruitment Status
Active, not recruiting
Study Start Date
May 21, 2021 (Actual)
Primary Completion Date
February 21, 2023 (Actual)
Study Completion Date
December 2024 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Beaver-Visitec International, Inc.
Collaborators
targomedGmbH

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
This is a multicentric, prospective, open-label PMCF study whereby patients undergoing routine cataract surgery will have mono- or bilateral implantation of hydrophobic acrylic monofocal toric intraocular lens PODEYE TORIC (study no. PHY2103)
Detailed Description
This is a multicentric, prospective, open-label PMCF study whereby patients undergoing routine cataract surgery will have mono- or bilateral implantation of hydrophobic acrylic monofocal toric intraocular lens PODEYE TORIC. The device under investigation is a hydrophobic acrylic monofocal toric intraocular lens (IOL) manufactured by the sponsor of this study. The refractive power of the lens has a spherical and a cylindrical component. The IOLs will be implanted in the course of routine cataract surgery and will benefit to patients suffering from cataract development and showing pre-existing corneal astigmatism. If only one eye qualifies for toric lens implantation due to small amount of pre-existing corneal astigmatism, one eye will be implanted with PODEYE TORIC and the contralateral eye will be received an implantation with the monofocal parent lens PODEYE. The study purpose is to determine safety, rotational stability, refractive and visual performance, contrast sensitivity, patient satisfaction and PCO rate after mono- or bilateral implantation of PODEYE TORIC intraocular lens. In total approx. 45 patients will be recruited for this clinical study and undergo mono- or bilateral implantation of PODEYE TORIC intraocular lens. The maximum time between 1st and 2nd eye implantation is 30 days. Subjects participating in the trial will attend a total of maximum 12 study visits over a period of 630-780 days (preoperative, operative, 1-2 days, 7-14 days, 30-60 days, 120-180 days, 330-420 days and 630-780 days postoperative visits). Subjects would have the option for unscheduled visits if required medically.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Cataract, Lens Opacities, Astigmatism
Keywords
Intraocular Lens, Monofocal, Toric Lens

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
45 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
PODEYE TORIC IOL Implantation experimental
Arm Type
Experimental
Arm Description
Mono- or bilateral implantation of toric intraocular lenses PODEYE TORIC
Intervention Type
Device
Intervention Name(s)
IOL implantation experimental
Intervention Description
Mono- or bilateral implantation of toric intraocular lenses PODEYE TORIC. If only one eye qualifies for toric lens implantation due to small amount of pre-existing corneal astigmatism, one eye will be implanted with PODEYE TORIC and the contralateral eye will be receive an implantation with the monofocal parent lens PODEYE (PhysIOL sa/nv, Liège, Belgium).
Primary Outcome Measure Information:
Title
Rotational stability - Photograph of IOL with dilated pupil to asses IOL rotation
Description
The primary performance endpoint is to show statistically non-inferior rotational stability outcomes on PODEYE TORIC lens compared to CER data obtained for a multifocal toric IOL (POD FT) by the same manufacturer sharing the same haptic design but based on a hydrophilic lens material. The null hypothesis is that the absolute mean IOL rotation measured on PODEYE TORIC is not larger than the absolute mean IOL rotation reported in the current CER on POD FT lens. The alternative hypothesis is that the absolute mean IOL rotation measured on PODEYE TORIC is larger than the outcomes reported in the current CER on POD FT lens. The measure is taken at 6 months postoperative visit compared to the measurement performed within 10 minutes after surgery.
Time Frame
6 months postoperative
Secondary Outcome Measure Information:
Title
Best Corrected Distance Visual Acuity compared to historical Data
Description
The objective is to compare CDVA above defined thresholds of the investigational product to the results of historical data of EN ISO 11979-7:2018, Annex E (Table E.3 and E.4). The null hypothesis for the CDVA is that / when the true rate of cases with visual acuity 0.3 logMAR or better is less than or equal to the SPE rate. The alternative hypothesis is that the "success" rate is higher than the SPE rate. If the distance corrected visual acuity is 0.3 logMAR or better in 30 eyes or more (with 36 eyes included), the null hypothesis could be rejected, and the alternative hypothesis could be accepted.
Time Frame
Pre-Op, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Change in cylindrical Power of the Eye
Description
Change in cylindrical power, defined as the difference between magnitude of preoperative keratometric cylinder and postoperative manifest cylinder is calculated at every Form. The outcomes of this calculation will be stratified per 0.25D step of preoperative keratometric cylinder and descriptive statistics (mean, standard deviation, median, minimum, maximum) will be provided.
Time Frame
Pre-Op, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Other Pre-specified Outcome Measures:
Title
Intraocular pressure (IOP) measurement
Description
The IOP will be measured with non-contact tonometer as part of the routine follow up examinations. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time Frame
Pre-Op, 1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Keratometry
Description
Keratometric measurements are performed to calculate the required IOL power. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time Frame
Pre-Op, 1 month postoperative, 6 months postoperative
Title
Biometry
Description
Biometry measurements are performed to calculate the required IOL power. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time Frame
Pre-Op
Title
IOL power
Description
The power of the implanted IOL must be recorded.
Time Frame
during surgery
Title
Target refraction
Description
The target refraction given by the IOL calculator is documented. This parameter is needed to calculate the accuracy of achieving the target refraction. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time Frame
during surgery
Title
Fundus OCT
Description
An OCT (optical coherence tomography) image will be taken at the preoperative visit to identify AMD suspicious eyes that need to be excluded from this study. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time Frame
Pre-Op, 6 months postoperative
Title
Pupil Size (photopic)
Description
Photopic pupil diameters are measured with a precision of at least +/-0.5 mm. For the photopic pupil diameters, eye illumination should be identical to that used for photopic contrast sensitivity testing. It is required that pupil measurements be made with an infrared pupillometer / CCD camera. Pupil measurements should only be made after the eye has had time to fully adapt to the testing conditions (at least 10 minutes). The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time Frame
Pre-Op, 6 months postoperative
Title
Pupil Size (mesopic)
Description
Mesopic pupil diameters are measured with a precision of at least +/-0.5 mm. For the mesopic pupil diameters, eye illumination should be identical to that used for mesopic contrast sensitivity testing. It is required that pupil measurements be made with an infrared pupillometer / CCD camera. Pupil measurements should only be made after the eye has had time to fully adapt to the testing conditions (at least 10 minutes). The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
Time Frame
Pre-Op, 6 months postoperative
Title
Manifest refraction
Description
The manifested refraction is measured by means of a phoropter. The data contains values for sphere, cylinder and axis of cylinder according to ISO 11979-7:2018.
Time Frame
Pre-Op, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Uncorrected Distance Visual Acuity (UDVA) - monocular
Description
UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2014. This assessment is done monocularly under photopic conditions.
Time Frame
Pre-Op, 1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Uncorrected Distance Visual Acuity (UDVA) - monocular mesopic
Description
UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2014. This assessment is done monocularly under mesopic conditions.
Time Frame
6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Uncorrected Distance Visual Acuity (UDVA) - binocular
Description
UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2014. This assessment is done binocularly under photopic conditions.
Time Frame
6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Uncorrected Distance Visual Acuity (UDVA) - binocular mesopic
Description
UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2014. This assessment is done binocularly under mesopic conditions.
Time Frame
6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Corrected Distance Visual Acuity (CDVA) - monocular
Description
CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2014. This assessment is done monocularly under photopic conditions.
Time Frame
Pre-Op, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Corrected Distance Visual Acuity (CDVA) - monocular mesopic
Description
CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2014. This assessment is done monocularly under mesopic conditions.
Time Frame
6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Corrected Distance Visual Acuity (CDVA) - binocular
Description
CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2014. This assessment is done binocularly under photopic conditions.
Time Frame
6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Corrected Distance Visual Acuity (CDVA) - binocular mesopic
Description
CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2014. This assessment is done binocularly under mesopic conditions.
Time Frame
6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Binocular Contrast Sensitivity under photopic light conditions
Description
Contrast Sensitivity under photopic light conditions using the standardized contrast sensitivity device Clinical Trial Suite (M&S Technologies). This examination is performed binocularly.
Time Frame
6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Binocular Contrast Sensitivity under mesopic light conditions
Description
Contrast Sensitivity under mesopic light conditions using the standardized contrast sensitivity device Clinical Trial Suite (M&S Technologies). This examination is performed binocularly.
Time Frame
6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Binocular Contrast Sensitivity under photopic light conditions and using a glare source
Description
Contrast Sensitivity under photopic light conditions with a glare source using the standardized contrast sensitivity device Clinical Trial Suite (M&S Technologies). This examination is performed binocularly.
Time Frame
6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Binocular Contrast Sensitivity under mesopic light conditions and using a glare source
Description
Contrast Sensitivity under mesopic light conditions with a glare source using the standardized contrast sensitivity device Clinical Trial Suite (M&S Technologies). This examination is performed binocularly.
Time Frame
6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Patient reported outcomes, Quality of Vision Questionnaire
Description
Outcomes measures of a questionnaire to address subjective study outcomes and disturbance by photic phenomena. For this study, the validated and verified questionnaire Quality of Vision (QoV) will be used. The QoV Questionnaire consists of a Rasch-tested, linear-scaled, 30-item instrument on three scales providing a QoV score in terms of symptom frequency, severity, and bothersome. It is suitable for measuring QoV in patients with all types of refractive correction, eye surgery, and eye disease that cause QoV problems [McAlinden, 2010]. The score ranges are 0 to 100 with smaller scales indicating better results.
Time Frame
Pre-Op, 6 months postoperative, 24 months postoperative
Title
Slitlamp examination - Corneal Status
Description
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Corneal Status
Time Frame
Pre-Op, 1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Fundus examination with dilated pupil
Description
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Fundus
Time Frame
Pre-Op, 1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Slitlamp examination - Signs of inflammation
Description
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: Signs of inflammation Anterior chamber cells, Anterior chamber flare, Cystoid macular oedema, Hypopyon, and Endophthalmitis
Time Frame
Pre-Op, 1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Slitlamp examination - Pupillary block
Description
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Pupillary block
Time Frame
Pre-Op, 1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Slitlamp examination - Retinal detachment
Description
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Retinal detachment
Time Frame
Pre-Op, 1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Slitlamp examination - Status of anterior and posterior capsule
Description
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • Status of anterior and posterior capsule
Time Frame
Pre-Op, 1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Slitlamp examination - IOL decentration
Description
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • IOL decentration
Time Frame
1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Slitlamp examination - IOL tilt
Description
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • IOL tilt
Time Frame
1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Slitlamp examination - IOL discoloration
Description
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • IOL discoloration
Time Frame
1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Slitlamp examination - IOL opacity
Description
The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp: • IOL opacity
Time Frame
1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Manual assessment of IOL axis position
Description
IOL axis will be subjectively measured by the examiner during the slit lamp examination with dilated eyes. Only for the PODEYE toric implanted eyes.
Time Frame
within 10 minutes after surgery, 1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
PCO grading
Description
Posterior capsule grading should be performed after pupil dilation at the follow up visits mentioned in the examination matrix. The status of the posterior capsule should be noted to be either "intact" or "not intact". If the capsule is intact, the presence of PCO and/or Elschnig's pearls will be documented as "present" or "absent". If "present", the location and clinical significance of the finding will be documented. Posterior capsular opacification (PCO) will be graded using the following scale: 0: None Minimal Mild Moderate Severe
Time Frame
1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Halo and Glare Scores (binocular)
Description
A Halo and Glare simulator software (Eyeland Design Network GmbH, Germany) will be used to assess the subjective perception of photic phenomena. The patients will be asked to adjust the halo and glare level in a simulated image to the amount they perceive of such photic phenomena. This test is performed pre- and postoperatively. The preoperative outcomes serve as a baseline measurement. This simulator utilizes a scale for intensity, size of the halo, and glare that ranges from zero (none) to 100 (extremely disturbing). It also allows for classifying the halos into three types, as follows: T1 (diffuse halo ring), T2 (starburst type), and T3 (distinct halo ring) [Kretz, 2015].
Time Frame
Pre-Op, 6 months postoperative, 24 months postoperative
Title
Safety outcomes
Description
The SPE rates of the investigational product will be compared to the results of historical data of EN ISO 11979-7:2018, Annex E (Table E.2). Rates of adverse events as determined by EN ISO 11979-7:2018 will be reported through the complete study follow-up. The proportion of all subjects with these events will be reported over time. Statistical comparisons to EN ISO 11979-7:2018 SPE (Safety and Performance Endpoints) rates (Annex E) will be based on all eyes implanted with the investigational device using a one-sided, exact test based on the binomial distribution.
Time Frame
Pre-Op, during surgery, 1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative
Title
Medication Revision
Description
Prior to the study start, a standard medication will be defined that all patients will receive and that is standard for cataract surgery. Only changes to the standard concomitant medication will be documented in the CRFs.
Time Frame
Pre-Op, during surgery, 1 day postoperative, 1 week postoperative, 1 month postoperative, 6 months postoperative, 12 months postoperative, 24 months postoperative

10. Eligibility

Sex
All
Minimum Age & Unit of Time
50 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Male or female adults ages 50 years or older on the day of screening who have clinically documented cataracts in both eyes; Calculated IOL power (sphere and cylinder) is within the range of the investigational IOLs; Regular corneal astigmatism (measured by a topographer); Corneal astigmatism ≥0.75 D and ≤ 4.25 D (measured by an automatic keratometer) in one or both eyes; Capability to understand and sign an IRB approved informed consent form and privacy authorization; Clear intraocular media other than cataract; Dilated pupil size large enough to visualize IOL axis markings postoperatively; Best corrected visual acuity projected to be better than 0.2 logMAR after toric IOL implantation; Willing and able to conform to the study requirements. Exclusion Criteria: Age of patient <50 years at the day of screening; Regular corneal astigmatism <0.75 D or >4.25 D (measured by an automatic keratometer) in both eyes Irregular astigmatism (measured by a topographer); Subjects with diagnosed degenerative visual disorders (e.g. macular degeneration or other retinal or optic disorders); Subjects with AMD suspicious eyes as determined by OCT examination; Previous intraocular or corneal surgery; Traumatic cataract; Clinically significant, uncontrolled glaucoma with expected negative impact on Contrast Sensitivity and/or visual acuity outcomes; Instability of keratometry or biometry measurements; Acceptable maximum standard deviation: AL: ± 150 µm; ACD: ± 150 µm; K1 / K2: ± 0.15 D; Ocular hypertension, suspicious glaucoma or glaucoma; Pregnant, lactating or, if able to bear children, unwilling to use medically acceptable birth control over the course of the study; Concurrent or previous (within 30 days) participation in another drug or device investigation; Clinically significant dry eye as determined by the investigator's judgement; Ocular surface disease (clinical symptoms or keratitis); Patients showing contraindications as listed in the current Instructions for use (IFU); Unsuitable for study participation for any other reason, as determined by Investigator's clinical judgment (reason to be documented on eCRF). In addition to above mentioned in- and exclusion criteria, subjects shall be discontinued when certain conditions are present at the time of surgery, including: zonular instability; need for iris manipulation; capsular fibrosis or other opacity; and inability to fixate IOL in desired position. In such cases, the subject shall be followed until the condition has stabilized.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Francisco Poyales Galan, MD
Organizational Affiliation
Miranza IOA Madrid
Official's Role
Principal Investigator
Facility Information:
Facility Name
Oftalvist Alicante
City
Alicante
ZIP/Postal Code
03016
Country
Spain
Facility Name
Miranza IMO Barcelona
City
Barcelona
ZIP/Postal Code
08035
Country
Spain
Facility Name
Miranza IOA Madrid
City
Madrid
ZIP/Postal Code
28003
Country
Spain
Facility Name
Oftalvist Juan Bravo
City
Madrid
ZIP/Postal Code
28006
Country
Spain
Facility Name
Miranza Virgen de Luján
City
Sevilla
ZIP/Postal Code
41011
Country
Spain
Facility Name
Oftalvist Valencia
City
Valencia
ZIP/Postal Code
46004
Country
Spain

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
20505205
Citation
McAlinden C, Pesudovs K, Moore JE. The development of an instrument to measure quality of vision: the Quality of Vision (QoV) questionnaire. Invest Ophthalmol Vis Sci. 2010 Nov;51(11):5537-45. doi: 10.1167/iovs.10-5341. Epub 2010 May 26.
Results Reference
background
PubMed Identifier
26274516
Citation
Kretz FT, Breyer D, Klabe K, Hagen P, Kaymak H, Koss MJ, Gerl M, Mueller M, Gerl RH, Auffarth GU. Clinical Outcomes After Implantation of a Trifocal Toric Intraocular Lens. J Refract Surg. 2015 Aug;31(8):504-10. doi: 10.3928/1081597X-20150622-01.
Results Reference
background

Learn more about this trial