search
Back to results

Accuracy of Trephination-based Versus Drilling-based Guided Dental Implant Placement

Primary Purpose

Single Tooth Lost, Partially Edentulous Maxilla

Status
Not yet recruiting
Phase
Not Applicable
Locations
Egypt
Study Type
Interventional
Intervention
guided trephination-based drilling protocol
guided Conventional drilling-based protocol
Sponsored by
Mohammed Ramadan
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional other trial for Single Tooth Lost focused on measuring guided implant, surgical guide, dental implant, dental trephination, guided trephination

Eligibility Criteria

20 Years - 50 Years (Adult)All SexesAccepts Healthy Volunteers

Inclusion Criteria:

  1. Single missing maxillary premolar or molar tooth.
  2. Both genders aged from 20-50 years.
  3. Patients should be systematically free from any disease as according to Cornell Medical Index-Health Questionnaire. (Pendleton et al,.2004)
  4. Mesio-distal space ≥ 7 mm.
  5. Bone width in bucco-lingual direction ≥ 6 mm.
  6. Uniform alveolar ridge with no undercuts.
  7. Present mesial and distal sound neighboring teeth.
  8. At least 4 natural remaining teeth on the same arch.
  9. Mouth opening at least 30 mm.

Exclusion Criteria:

1) Pregnant and lactating females. 2) Smokers. 3) Poor oral hygiene. 4) Vulnerable groups of patients' e.g. (handicapped patients).

-

Sites / Locations

  • AinShams University

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

guided trephination-based protocol

guided conventional drilling-based protocol

Arm Description

The drilling process will be performed by guided trephination protocol. An appropriate trephine drill (Helmut Zepf Medizintechnik GmbH, Germany) will be used to create an initial osteotomy. The guide will be removed, and the depth and angulation of this initial osteotomy will be evaluated. The final drill of the chosen implant system will be used to complete the osteotomy. The implant (NeoBiotech Implant System, Neobiotech Co. Ltd. Korea) then will be placed freehand in a conventional manner.

The drilling process will be performed by a guided conventional drilling protocol. Drilling (Neo NaviGuide System - Neobiotech Co. Ltd. Korea) will be performed throughout the guiding sleeve from the first drill to the final drill. The guide will be removed. The implant (NeoBiotech Implant System, Neobiotech Co. Ltd. Korea) then will be placed freehand in a conventional manner.

Outcomes

Primary Outcome Measures

Horizontal deviation at apex of the implant.
measure the Horizontal deviation at apex of the implant between the virtual planning position and the actual implant position
•Horizontal deviation at implant shoulder.
measure the Horizontal deviation at the implant shoulder between the virtual planning position and the actual implant position
Angular deviation.
measure the Angular deviation of the implant between the virtual planning position and the actual implant position

Secondary Outcome Measures

The duration of the surgery
measure the time of the surgery from the first drill to the implant placement
Satisfaction assessed by the Visual Analogue Scale
measure the patient satisfaction score on terms of pain and discomfort from 1 to 10

Full Information

First Posted
March 3, 2022
Last Updated
July 23, 2022
Sponsor
Mohammed Ramadan
search

1. Study Identification

Unique Protocol Identification Number
NCT05295082
Brief Title
Accuracy of Trephination-based Versus Drilling-based Guided Dental Implant Placement
Official Title
Accuracy of Trephination-based Versus Drilling-based Guided Dental Implant Placement: A Randomized Clinical Study
Study Type
Interventional

2. Study Status

Record Verification Date
July 2022
Overall Recruitment Status
Not yet recruiting
Study Start Date
December 2022 (Anticipated)
Primary Completion Date
March 2023 (Anticipated)
Study Completion Date
June 2023 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor-Investigator
Name of the Sponsor
Mohammed Ramadan

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
This study will be initiated to compare the accuracy of implant placement using the guided trephination drilling protocol and the guided conventional drilling protocol.
Detailed Description
This study will be conducted to compare the accuracy of implant placement using the guided trephination drilling protocol and the guided conventional drilling protocol. the patients with a single missing tooth will be assigned to one group ( trephination drilling / conventional drilling ).the preoperative virtual planning and fabrication of a surgical guide will be made for each patient. after implant placement according to each group, postoperative (CBCT ) will be performed to compare the virtual implant position and the actual implant position.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Single Tooth Lost, Partially Edentulous Maxilla
Keywords
guided implant, surgical guide, dental implant, dental trephination, guided trephination

7. Study Design

Primary Purpose
Other
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Outcomes Assessor
Allocation
Randomized
Enrollment
22 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
guided trephination-based protocol
Arm Type
Experimental
Arm Description
The drilling process will be performed by guided trephination protocol. An appropriate trephine drill (Helmut Zepf Medizintechnik GmbH, Germany) will be used to create an initial osteotomy. The guide will be removed, and the depth and angulation of this initial osteotomy will be evaluated. The final drill of the chosen implant system will be used to complete the osteotomy. The implant (NeoBiotech Implant System, Neobiotech Co. Ltd. Korea) then will be placed freehand in a conventional manner.
Arm Title
guided conventional drilling-based protocol
Arm Type
Active Comparator
Arm Description
The drilling process will be performed by a guided conventional drilling protocol. Drilling (Neo NaviGuide System - Neobiotech Co. Ltd. Korea) will be performed throughout the guiding sleeve from the first drill to the final drill. The guide will be removed. The implant (NeoBiotech Implant System, Neobiotech Co. Ltd. Korea) then will be placed freehand in a conventional manner.
Intervention Type
Procedure
Intervention Name(s)
guided trephination-based drilling protocol
Intervention Description
the implant site preparation in this group will be done by guided trephination protocol which uses the surgical guide to trephine the implant site then remove the guide and continue the drilling in a freehand manner
Intervention Type
Procedure
Intervention Name(s)
guided Conventional drilling-based protocol
Intervention Description
the implant site preparation in this group will be done by a guided conventional drilling protocol which uses the surgical guide to guide the sequential drills up to the final drill
Primary Outcome Measure Information:
Title
Horizontal deviation at apex of the implant.
Description
measure the Horizontal deviation at apex of the implant between the virtual planning position and the actual implant position
Time Frame
immediately after the intervention
Title
•Horizontal deviation at implant shoulder.
Description
measure the Horizontal deviation at the implant shoulder between the virtual planning position and the actual implant position
Time Frame
immediately after the intervention
Title
Angular deviation.
Description
measure the Angular deviation of the implant between the virtual planning position and the actual implant position
Time Frame
immediately after the intervention
Secondary Outcome Measure Information:
Title
The duration of the surgery
Description
measure the time of the surgery from the first drill to the implant placement
Time Frame
during the surgery
Title
Satisfaction assessed by the Visual Analogue Scale
Description
measure the patient satisfaction score on terms of pain and discomfort from 1 to 10
Time Frame
immediately after the intervention

10. Eligibility

Sex
All
Minimum Age & Unit of Time
20 Years
Maximum Age & Unit of Time
50 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria: Single missing maxillary premolar or molar tooth. Both genders aged from 20-50 years. Patients should be systematically free from any disease as according to Cornell Medical Index-Health Questionnaire. (Pendleton et al,.2004) Mesio-distal space ≥ 7 mm. Bone width in bucco-lingual direction ≥ 6 mm. Uniform alveolar ridge with no undercuts. Present mesial and distal sound neighboring teeth. At least 4 natural remaining teeth on the same arch. Mouth opening at least 30 mm. Exclusion Criteria: 1) Pregnant and lactating females. 2) Smokers. 3) Poor oral hygiene. 4) Vulnerable groups of patients' e.g. (handicapped patients). -
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Mohammed Ramadan, bachelor
Phone
01003274889
Email
dentistmh93@gmail.com
Facility Information:
Facility Name
AinShams University
City
Cairo
Country
Egypt

12. IPD Sharing Statement

Plan to Share IPD
No
IPD Sharing Plan Description
the data that will be shared is the CBCT, virtual planning
Citations:
PubMed Identifier
30503150
Citation
Suriyan N, Sarinnaphakorn L, Deeb GR, Bencharit S. Trephination-based, guided surgical implant placement: A clinical study. J Prosthet Dent. 2019 Mar;121(3):411-416. doi: 10.1016/j.prosdent.2018.06.004. Epub 2018 Nov 30.
Results Reference
result
PubMed Identifier
23062136
Citation
Van Assche N, Vercruyssen M, Coucke W, Teughels W, Jacobs R, Quirynen M. Accuracy of computer-aided implant placement. Clin Oral Implants Res. 2012 Oct;23 Suppl 6:112-23. doi: 10.1111/j.1600-0501.2012.02552.x.
Results Reference
result
PubMed Identifier
23593625
Citation
Cassetta M, Stefanelli LV, Giansanti M, Di Mambro A, Calasso S. Accuracy of a computer-aided implant surgical technique. Int J Periodontics Restorative Dent. 2013 May-Jun;33(3):317-25. doi: 10.11607/prd.1019.
Results Reference
result

Learn more about this trial

Accuracy of Trephination-based Versus Drilling-based Guided Dental Implant Placement

We'll reach out to this number within 24 hrs