Detecting Tissue Ischemia in Reconstruction Flaps by a Novel CO2 Biosensor (DIMENSION-study) (DIMENSION)
Primary Purpose
Ischemia, Blood Circulation Disorder, Biosensing Techniques
Status
Recruiting
Phase
Not Applicable
Locations
Norway
Study Type
Interventional
Intervention
IscAlert
Sponsored by
About this trial
This is an interventional diagnostic trial for Ischemia focused on measuring Ischemia, Biosensor, Reconstructive, Surgery, Carbon dioxide, Flap
Eligibility Criteria
Inclusion Criteria:
- Patients must be scheduled for reconstructive flap surgery
- surgery
- Patients must be ≥ 18 years
- Patients must be able to give written signed informed consent
Exclusion Criteria:
• Another study interfering with current study
Sites / Locations
- Oslo University HospitalRecruiting
Arms of the Study
Arm 1
Arm Type
Experimental
Arm Label
Patients with reconstructed flap monitored by tissue CO2
Arm Description
Patients scheduled for reconstructive flap surgery are monitored postoperatively with IscAlert biosensor measuring local tissue CO2 and temperature in the reconstructed flap
Outcomes
Primary Outcome Measures
Tissue CO2-level
Tissue CO2-level (kPa) during insertion period
Secondary Outcome Measures
Bleeding
Amount of blood from insertion site (ml)
Infection
Infection from insertion site at the discretion of the investigator (yes or no)
Length of stay at hospital
Number of days from end of initial operation to primary hospital discharge + Number of days from transfer from primary hospital to discharge from secondary hospital.
Time to reduced blood flow in reconstructed flap
Number of days and hours from primary surgery end to obstructed blood flow is diagnosed
Number of re-operations
Number of reoperations caused by replant necrosis/ischemia in the reconstructed flap
Full Information
NCT ID
NCT05487820
First Posted
August 2, 2022
Last Updated
October 17, 2023
Sponsor
Oslo University Hospital
Collaborators
Sensocure AS
1. Study Identification
Unique Protocol Identification Number
NCT05487820
Brief Title
Detecting Tissue Ischemia in Reconstruction Flaps by a Novel CO2 Biosensor (DIMENSION-study)
Acronym
DIMENSION
Official Title
Detecting Tissue Ischemia in Reconstruction Flaps by a Novel CO2 Biosensor (DIMENSION-study); An Open, Prospective, Intervention Study
Study Type
Interventional
2. Study Status
Record Verification Date
October 2023
Overall Recruitment Status
Recruiting
Study Start Date
October 13, 2023 (Actual)
Primary Completion Date
October 28, 2024 (Anticipated)
Study Completion Date
October 1, 2025 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Oslo University Hospital
Collaborators
Sensocure AS
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No
5. Study Description
Brief Summary
The investigators will test if changes in CO2 is detected postoperatively in ischemic tissue in a reconstructed flap.
IscAlert is measuring continuously CO2 in muscular and subcutaneous tissue. IscAlert is inserted distal to the operative field into normal muscle and/or subcutaneous tissue in the reconstructed flap. Local tissue CO2 and temperature will be monitored continuously postoperatively until maximal 10 days.
If a reduced or totally obstructed blood flow appear (thrombosis), an increase in tissue CO2 and a lower local temperature will emerge rapidly as a sign of ischemia. This will be detected by the sensor which will alarm the investigators.
This will lead to assessment of the reconstructed flap and if restricted blood flow is diagnosed, a reoperation or other intervention will be performed. 56 patients will be enrolled to undergo the procedures. The IscAlert will be removed from the patient before the patient is discharged from the hospital or a maximum of 10 days (the event that occurs first). 360 devices are planned to be used in this clinical study.
Detailed Description
This is an open, prospective, interventional, single-center clinical investigation designed to examine the feasibility and safety of the IscAlert™ device in patients scheduled for reconstructive flap surgery. 56 will be enrolled to undergo the procedures using a total of 350 devices depending on the injuries. IscAlert is 0.8 mm in diameter and in vitro testing, shows stable and accurate measurements of pCO2. More than 200 animal experiments have been done with the sensor. The experiments have shown that the sensor detects ischemia (Increased CO2-measurements) in real time in the following organs and tissues: Brain, heart, liver, kidneys, pancreas, intestines, musculature and subcutaneous tissue. Sensitivity and specificity are close to 100%. The sensors are inserted into tissue by a split needle technique. The split needle is the size of a 3-gauge peripheral venous catheter. In animal studies, no complications have been detected when using the sensor. The IscAlert sensors are connected to an electronics unit that is fixed to the skin with an adhesive plaster or glue outside the sterile area. The electrical signals are redirected to a PC approved for clinical use which continuously records tissue pressures of CO2. IscAlert is inserted into normal muscle and/or subcutaneous tissue distal on the reconstructed flap to be operated at the end of surgery. The insertion is far away from the operating field. The insertion is done under sterile conditions in accordance with standard sterility criteria at the hospital. No pain during insertion will occur because of insertion is performed during general anesthesia. Also, the insertion can be compared to an intramuscular injection. Postoperatively, the IscAlert sensor will continuously monitoring tissue CO2 and temperature. If ischemia occur, for examples caused by a thrombus, an increase in tissue CO2 and a lower temperature will evolve. This will be detected by the sensor which will alarm the investigators. This will lead to assessment of the reconstructed flap and if restricted blood flow is diagnosed, a reoperation or other intervention will be performed. The IscAlert will be removed from the patient before the patient is discharged from the hospital or a maximum of 10 days (the event that occurs first). Approximately 360 devices are planned to be used in this clinical study. One of the sensors will be used as a control inserted into neighboring tissue.
The primary objective is to compare CO2-levels in the reconstructed flap in individuals who has undergone reconstructed flap surgery and investigate if CO2-level is different in patient diagnosed with obstructed blood flow vs. patients with sufficient blood flow in the reconstructed flap.
Our hypotheses are:
The IscAlert™ device will be able to detect the presence of ischemia in the reconstructed flap by increased pCO2 levels and decrease in tissue temperature, measured by IscAlert™.
By using the IscAlert™ device monitoring ischemic events, an early treatment for ischemia could lead to higher incidence of reconstructed flap survival rates, and less revision surgery caused by thrombosis.
No clinically significant bleeding or infection will occur using IscAlert™ in this clinical study.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Ischemia, Blood Circulation Disorder, Biosensing Techniques, Surgery
Keywords
Ischemia, Biosensor, Reconstructive, Surgery, Carbon dioxide, Flap
7. Study Design
Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Model Description
Prospective, interventional. Hundred-and-sixty (56) patients will receive tissue CO2 monitoring in a reconstructed flap after reconstructive flap surgery.
Masking
None (Open Label)
Masking Description
None (Open Label)
Allocation
N/A
Enrollment
160 (Anticipated)
8. Arms, Groups, and Interventions
Arm Title
Patients with reconstructed flap monitored by tissue CO2
Arm Type
Experimental
Arm Description
Patients scheduled for reconstructive flap surgery are monitored postoperatively with IscAlert biosensor measuring local tissue CO2 and temperature in the reconstructed flap
Intervention Type
Device
Intervention Name(s)
IscAlert
Intervention Description
Insertion of a CO2- and temperature sensor(s) in the reconstructed flap.
Primary Outcome Measure Information:
Title
Tissue CO2-level
Description
Tissue CO2-level (kPa) during insertion period
Time Frame
10 days
Secondary Outcome Measure Information:
Title
Bleeding
Description
Amount of blood from insertion site (ml)
Time Frame
10 days
Title
Infection
Description
Infection from insertion site at the discretion of the investigator (yes or no)
Time Frame
30 days
Title
Length of stay at hospital
Description
Number of days from end of initial operation to primary hospital discharge + Number of days from transfer from primary hospital to discharge from secondary hospital.
Time Frame
30 days
Title
Time to reduced blood flow in reconstructed flap
Description
Number of days and hours from primary surgery end to obstructed blood flow is diagnosed
Time Frame
30 days
Title
Number of re-operations
Description
Number of reoperations caused by replant necrosis/ischemia in the reconstructed flap
Time Frame
30 days
Other Pre-specified Outcome Measures:
Title
Number of pack-years
Description
Smoking habit; number of pack-years by participants
Time Frame
30 days
Title
Warm ischemia time
Description
Intraoperative ischemia time of the flap (minutes)
Time Frame
12 hours
Title
Intravenous fluid
Description
Intravenous fluid given during surgery (ml)
Time Frame
12 hours
Title
Vasoactive drugs
Description
Vasoactive drugs given during surgery (microgram)
Time Frame
12 hours
Title
Arterial CO2 level
Description
Arterial blood gass analysis of CO2 during hospital stay (kPa)
Time Frame
10 days
Title
Arterial PH level
Description
Arterial blood gass analysis of PH during hospital stay (kPa)
Time Frame
10 days
Title
Arterial lactate level
Description
Arterial blood gass analysis of lactate during hospital stay (kPa)
Time Frame
10 days
Title
Arterial HCO3 level
Description
Arterial blood gass analysis of HCO3 during hospital stay (kPa)
Time Frame
10 days
Title
End-tidal level of CO2
Description
End-tidal level of CO2 during hospital stay (kPa)
Time Frame
10 days
Title
IscAlert functionality
Description
Number of hours with a well-functioning sensor (giving CO2- and temperature data)
Time Frame
10 days
Title
Physical examination of the reconstructed flap - capillary filling
Description
Time of capillary filling (seconds)
Time Frame
10 days
Title
Physical examination of the reconstructed flap - color
Description
Color of reimplanted extremity (Red or Pale)
Time Frame
10 days
Title
Physical examination of the reconstructed flap - SpO2
Description
SpO2 of reimplanted extremity (%)
Time Frame
10 days
Title
Physical examination of the reconstructed flap - temperature
Description
Temperature of reimplanted extremity (degrees Celsius)
Time Frame
10 days
Title
SpO2
Description
SpO2 measured at a finger (%)
Time Frame
10 days
Title
Examination of the reconstructed flap - Doppler
Description
Doppler flowmeter monitoring flow velocity in vascular flap bed (mL/min)
Time Frame
10 days
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Patients must be scheduled for reconstructive flap surgery
surgery
Patients must be ≥ 18 years
Patients must be able to give written signed informed consent
Exclusion Criteria:
• Another study interfering with current study
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Magne Røkkum, MD, Ph.D
Phone
90839385
Ext
+47
Email
magne.rokkum@medisin.uio.no
First Name & Middle Initial & Last Name or Official Title & Degree
Tor Inge Tønnessen, MD, Ph.D
Phone
91700717
Ext
+47
Email
t.i.tonnessen@medisin.uio.no
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Magne Røkkum, MD, Ph.D
Organizational Affiliation
Oslo University Hospital
Official's Role
Principal Investigator
Facility Information:
Facility Name
Oslo University Hospital
City
Oslo
ZIP/Postal Code
0424
Country
Norway
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Magne Røkkum, MD, Ph.D
Phone
908393856
Ext
+47
Email
magne.rokkum@medisin.uio.no
First Name & Middle Initial & Last Name & Degree
Tor Inge Tønnessen, MD, Ph.D
Phone
23073692
Ext
+47
Email
t.i.tonnessen@medisin.uio.no
First Name & Middle Initial & Last Name & Degree
Johanne Korslund, MD
First Name & Middle Initial & Last Name & Degree
Christina Stuedal, MD
First Name & Middle Initial & Last Name & Degree
Kim A Tønseth, MD, Ph.d
12. IPD Sharing Statement
Plan to Share IPD
No
IPD Sharing Plan Description
No plan to share IPD to other researchers
Learn more about this trial
Detecting Tissue Ischemia in Reconstruction Flaps by a Novel CO2 Biosensor (DIMENSION-study)
We'll reach out to this number within 24 hrs