search
Back to results

A Randomized Controlled Trial of No Strings Intrauterine Device (IUD) Removal Techniques

Primary Purpose

IUD Threads Not Visible, IUD Removal Complication

Status
Recruiting
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
IUD removal with no visible strings
Alligator forceps
Manual Vacuum Aspirator
Sponsored by
University of Colorado, Denver
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for IUD Threads Not Visible

Eligibility Criteria

18 Years - 45 Years (Adult)FemaleAccepts Healthy Volunteers

Inclusion Criteria: Female Ages 18 - 45 years old Confirmed intrauterine IUD by pelvic ultrasound Desires IUD removal Exclusion Criteria: Currently pregnant IUD strings are visible Partial retained IUD (e.g. IUD arm only) Unwilling to be randomized to either arm

Sites / Locations

  • Comprehensive Women's Health CenterRecruiting

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Experimental

Arm Label

Removal with alligator forceps

Removal with manual vacuum aspiration

Arm Description

Standard of care removal with passage of an intrauterine alligator forceps under ultrasound guidance to grasp and remove the IUD. If required, multiple attempts will be performed using this technique.

Intrauterine placement of an MVA under ultrasound guidance adjacent to the IUD to remove the IUD. Multiple attempts will be performed up to a maximum of 3 unsuccessful MVA attempts, after which time, the provider will switch to the alligator forceps technique, given that this is the current standard of care.

Outcomes

Primary Outcome Measures

First-pass IUD removal rates
To compare the first-pass intrauterine device (IUD) removal rates of using manual vacuum aspiration versus alligator forceps for IUD removal with no visible strings.

Secondary Outcome Measures

Overall IUD removal success rates
To describe the overall success rates of IUD removal with no visible strings using alligator forceps versus manual vacuum aspiration.

Full Information

First Posted
January 5, 2023
Last Updated
January 17, 2023
Sponsor
University of Colorado, Denver
search

1. Study Identification

Unique Protocol Identification Number
NCT05702242
Brief Title
A Randomized Controlled Trial of No Strings Intrauterine Device (IUD) Removal Techniques
Official Title
A Randomized Controlled Trial of No Strings Intrauterine Device (IUD) Removal Techniques: Alligator Forceps Versus Manual Vacuum Aspiration (MVA)
Study Type
Interventional

2. Study Status

Record Verification Date
January 2023
Overall Recruitment Status
Recruiting
Study Start Date
January 2023 (Anticipated)
Primary Completion Date
June 2024 (Anticipated)
Study Completion Date
December 2024 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University of Colorado, Denver

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
The goal of this clinical trial is to compare success rates of two removal techniques for intrauterine devices (IUDs) that have missing or non-visible strings. The investigators will also collect preliminary data to better understand patient and provider satisfaction, maximum pain score, procedure time, and complications with the two techniques. Participants will be randomized to IUD removal with either an alligator forceps or manual vacuum aspiration (MVA) technique. This study will provide important data on these removal techniques, which could possibly expand options for and access to no strings IUD removals.
Detailed Description
Intrauterine devices (IUDs) are a commonly used, highly effective form of long-acting reversible contraception in the United States. Approximately 4-18% of people with an IUD in place with have missing or non-visible IUD strings, mostly commonly due to IUD string retraction into the cervix. Currently, expert opinion suggests to remove IUDs with no visible strings using by using an alligator forceps that is placed into the uterine cavity with or without ultrasound guidance. Removal of no strings IUDs with manual vacuum aspiration (MVA) has been suggested as a possible alternative to alligator forceps. MVA is a commonly used technique for the management of miscarriage, abortion, and endometrial sampling and has potential benefits as a low cost, portable device that is readily available in family planning clinic and many office-based obstetrics and gynecology practices. The study will compare MVA to alligator forceps for IUD removal with no visible strings. The investigators will enroll females presenting for no strings IUD removals. Potential participants will be screened for eligibility and will be excluded if they have visible IUD strings, have a positive pregnancy test, have a partially retained IUD (e.g., IUD arm only), or are unwilling to be randomized to either arm. The investigators will perform a screening pelvic exam and transvaginal ultrasound (if not already completed prior to the visit). Participants will then be randomized to one of the two removal techniques: MVA or alligator forceps. The investigators will document successful removal with the first pass of the instrument as well as successful removal with multiple attempts of the same technique. A maximum of 3 MVA removal attempts will be performed after which time, the provider will switch to using an alligator forceps as the current standard of care. Preliminary data will also be collected on patient and provider satisfaction, patient pain scores, procedure time, and complications. This study will provide important data on MVA as a technique for IUD removals with no visible strings. No studies have compared IUD removal techniques and expanding options for removal techniques has the potential to increase access to care.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
IUD Threads Not Visible, IUD Removal Complication

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
75 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
Removal with alligator forceps
Arm Type
Experimental
Arm Description
Standard of care removal with passage of an intrauterine alligator forceps under ultrasound guidance to grasp and remove the IUD. If required, multiple attempts will be performed using this technique.
Arm Title
Removal with manual vacuum aspiration
Arm Type
Experimental
Arm Description
Intrauterine placement of an MVA under ultrasound guidance adjacent to the IUD to remove the IUD. Multiple attempts will be performed up to a maximum of 3 unsuccessful MVA attempts, after which time, the provider will switch to the alligator forceps technique, given that this is the current standard of care.
Intervention Type
Procedure
Intervention Name(s)
IUD removal with no visible strings
Intervention Description
Removal with either alligator forceps or MVA
Intervention Type
Device
Intervention Name(s)
Alligator forceps
Intervention Description
IUD removal with alligator forceps
Intervention Type
Device
Intervention Name(s)
Manual Vacuum Aspirator
Other Intervention Name(s)
Ipas 60-mL double valve aspirator
Intervention Description
IUD removal with MVA
Primary Outcome Measure Information:
Title
First-pass IUD removal rates
Description
To compare the first-pass intrauterine device (IUD) removal rates of using manual vacuum aspiration versus alligator forceps for IUD removal with no visible strings.
Time Frame
12-18 months
Secondary Outcome Measure Information:
Title
Overall IUD removal success rates
Description
To describe the overall success rates of IUD removal with no visible strings using alligator forceps versus manual vacuum aspiration.
Time Frame
12-18 months
Other Pre-specified Outcome Measures:
Title
Preliminary data on satisfaction
Description
To gather preliminary data on patient and provider satisfaction.
Time Frame
12-18 months
Title
Preliminary data on pain scores
Description
To gather preliminary data on maximum procedural pain scores measured by visual analog scale (VAS).
Time Frame
12-18 months
Title
Preliminary data on procedure time
Description
To gather preliminary data on total procedure time.
Time Frame
12-18 months
Title
Preliminary data on complications
Description
To gather preliminary data on complications of no strings IUD removals.
Time Frame
12-18 months

10. Eligibility

Sex
Female
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
45 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria: Female Ages 18 - 45 years old Confirmed intrauterine IUD by pelvic ultrasound Desires IUD removal Exclusion Criteria: Currently pregnant IUD strings are visible Partial retained IUD (e.g. IUD arm only) Unwilling to be randomized to either arm
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Cara Clure, MD
Phone
303-724-8482
Email
cara.clure@cuanschutz.edu
First Name & Middle Initial & Last Name or Official Title & Degree
Eva Dindinger, MPH
Phone
303-724-8482
Email
eva.dindinger@cuanschutz.edu
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Cara Clure, MD
Organizational Affiliation
University of Colorado, Denver
Official's Role
Principal Investigator
Facility Information:
Facility Name
Comprehensive Women's Health Center
City
Denver
State/Province
Colorado
ZIP/Postal Code
80230
Country
United States
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Cara Clure, MD
Phone
303-724-8576
Email
cara.clure@cuanschutz.edu
First Name & Middle Initial & Last Name & Degree
Eva Dindinger, MPH
Phone
303-724-8482
Email
eva.dindinger@cuanschutz.edu

12. IPD Sharing Statement

Citations:
PubMed Identifier
21237334
Citation
Prabhakaran S, Chuang A. In-office retrieval of intrauterine contraceptive devices with missing strings. Contraception. 2011 Feb;83(2):102-6. doi: 10.1016/j.contraception.2010.07.004. Epub 2010 Aug 23. No abstract available.
Results Reference
background
PubMed Identifier
22459233
Citation
Marchi NM, Castro S, Hidalgo MM, Hidalgo C, Monteiro-Dantas C, Villarroeal M, Bahamondes L. Management of missing strings in users of intrauterine contraceptives. Contraception. 2012 Oct;86(4):354-8. doi: 10.1016/j.contraception.2012.01.018. Epub 2012 Mar 27.
Results Reference
background
PubMed Identifier
25708503
Citation
Verma U, Astudillo-Davalos FE, Gerkowicz SA. Safe and cost-effective ultrasound guided removal of retained intrauterine device: our experience. Contraception. 2015 Jul;92(1):77-80. doi: 10.1016/j.contraception.2015.02.008. Epub 2015 Feb 21.
Results Reference
background
PubMed Identifier
24835830
Citation
Swenson C, Royer PA, Turok DK, Jacobson JC, Amaral G, Sanders JN. Removal of the LNG IUD when strings are not visible: a case series. Contraception. 2014 Sep;90(3):288-90. doi: 10.1016/j.contraception.2014.04.007. Epub 2014 Apr 21.
Results Reference
background
PubMed Identifier
23802598
Citation
Mizia K, Ramsay P. The effectiveness and safety of ultrasound-guided removal of a Mirena((R)) intrauterine system when the strings are not visible and conventional office procedures have failed. Aust N Z J Obstet Gynaecol. 2013 Aug;53(4):386-8. doi: 10.1111/ajo.12103. Epub 2013 Jun 26.
Results Reference
background
PubMed Identifier
34197636
Citation
da Silva Nobrega AB, Pitangui ACR, Vieira CS. Factors associated with missing strings and expulsion after postplacental insertion of copper T380A intrauterine devices. Int J Gynaecol Obstet. 2022 Apr;157(1):67-75. doi: 10.1002/ijgo.13806. Epub 2021 Jul 27.
Results Reference
background
PubMed Identifier
21354074
Citation
Wu JP, Porch E, Womack JP. Successful retrieval of an intrauterine device with "missing strings" using a manual vacuum aspirator in a desired early pregnancy: case report. J Minim Invasive Gynecol. 2011 Mar-Apr;18(2):254-6. doi: 10.1016/j.jmig.2010.11.008.
Results Reference
background
PubMed Identifier
34566303
Citation
Jain A, Singh S, Elliyas S. Effectiveness of Manual Vacuum Aspiration (MVA) Device in the Management of Intrauterine Copper Devices (IUCD) with Missing Strings: A Prospective Interventional Study. J Obstet Gynaecol India. 2021 Aug;71(4):424-429. doi: 10.1007/s13224-021-01440-x. Epub 2021 Mar 15.
Results Reference
background
PubMed Identifier
12309485
Citation
Guillebaud J, Kasonde JM. A simple scheme for managing the problem of 'lost threads' with intrauterine devices. Fertil Contracept. 1979 Apr;3(2):24-32.
Results Reference
background

Learn more about this trial

A Randomized Controlled Trial of No Strings Intrauterine Device (IUD) Removal Techniques

We'll reach out to this number within 24 hrs