A High-density Microelectrode for Human Neuronal Recordings

Primary Purpose

Parkinson Disease, Idiopathic

Status
Not yet recruiting
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
DBC (Diagnostic Biochips) Deep Array microelectrode; Intan Electrophysiology recording system; Matlab response recording to behavioral task
Sponsored by
Cedars-Sinai Medical Center
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional basic science trial for Parkinson Disease, Idiopathic focused on measuring Parkinson's, DBS, Electrode

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria: Any patient undergoing implantation of a Deep Brain Stimulating (DBS) electrode in the Subthalamic nucleus (STN) for the treatment of Parkinson's disease, in whom microelectrode recording is being performed to improve localization of the STN. Age > 18 years of age Able to give independent informed consent Exclusion Criteria: Microelectrode recording is not indicated Previous implantation of DBS electrodes in this site Known allergic reaction to stainless steel or polyimide

Sites / Locations

  • Cedars-Sinai Medical Center

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

Neuronal Recording and Behavioral Testing

Arm Description

Neuronal Recording and Behavioral Testing

Outcomes

Primary Outcome Measures

Neuronal Activity
Single Neuron firing rate (spikes) measured in spikes per second - total number of isolated neurons, amplitude (in uV of spikes) - by Intan Neurophysiology Recording System
Breakage of Electrode
Extent of fracture of electrode tip measured in micrometers by a light microscope

Secondary Outcome Measures

Full Information

First Posted
June 9, 2023
Last Updated
August 29, 2023
Sponsor
Cedars-Sinai Medical Center
search

1. Study Identification

Unique Protocol Identification Number
NCT05919160
Brief Title
A High-density Microelectrode for Human Neuronal Recordings
Official Title
Assessment of Safety and Utility of a High-density Microelectrode for Human Neuronal Recording
Study Type
Interventional

2. Study Status

Record Verification Date
August 2023
Overall Recruitment Status
Not yet recruiting
Study Start Date
September 2023 (Anticipated)
Primary Completion Date
December 2023 (Anticipated)
Study Completion Date
December 2023 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Cedars-Sinai Medical Center

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No

5. Study Description

Brief Summary
The purpose of this study is to test the ability of a newly-designed electrode to measure the activity of individual nerve cells (neurons), and collections of nerve cells (local field potentials) in the brain. The study's main goals are to see how well this electrode works compared to standard electrodes and to validate its safety.
Detailed Description
Recording of human brain activity at many scales is an important tool in clinical medicine. The ability to record extracellular action potentials, otherwise known as a "single unit activity" (SUA) has provided fundamental insight into the details of neuronal function in humans as well as a variety of nonhuman animals. In humans the techniques for recording extracellular action potentials are relatively limited. Rigid, sharp tipped probes manufactured by several companies are FDA approved and routinely used as part of standard of care during a variety of surgical procedures such as deep brain stimulation (DBS) device implantation to identify areas of neuronal activity and optimize placement of clinical electrodes. The same technique has been used to better understand brain function and its impairment by disease in humans. In addition, a variety of semi- chronically implanted microwire techniques are available. These electrodes are more commonly used in patients with seizure disorders and have allowed insight into network behavior such as in the medial temporal lobe and medial frontal lobe. However there remains a tremendous gap between the recording capabilities of modern electrodes used in animal research, and what is currently clinically available for human testing. A typical rigid shaft single electrode currently used in clinical care will record anywhere from 1-3 distinctly isolated neurons at a time. In contrast, in state-of-the art animal research, higher density probes such as the Neuropixel electrode [4-6] now routinely allow recording of hundreds or even thousands of neurons in a single brain region. This markedly increased recording capability translates directly into a better understanding of how brain neurons and networks interact to create complex behaviors and disease. Most of the commonly used high-density electrodes are based on a rigid silicon shaft onto which multiple recording contacts (typically made of platinum, Iridium, gold or conductive polymers) are embedded. There are several significant limitations of silicon-based probes in translating them to large brain, and in particular human, applications [7] First, silicon is fragile, making the electrodes prone to fracture, which makes them risky for human applications. Furthermore, the silicon microfabrication process is impractical for making large devices, limiting commercially available probe length to around 20mm, which is too short for most clinical applications in the human brain. Also, the connection between the electrode contacts and the pre-amplifier in the currently available products requires a rigid circuit board that is attached to the electrode, which is difficult to work with and which requires that the pre-amplifiers to be kept very close to the brain. While there are FDA approved version of silicon probes (i.e. the Utah Array used for brain machine interfaces), these applications are limited to short <2mm long probes used for surface cortical recordings. The inherent material and process limitations described make it unlikely that silicon-based probe technologies will provide a clinically usable probe for deeper locations in the human brain. The investigators, therefore, sought to utilize a new kind of translatable technology for clinical use. The investigators seek to test a more robust and reliable technique for recording large numbers of single neurons in the human brain. Diagnostic Biochips Inc. (Glen Burnie, MD) is an electrode manufacturer that has developed a new type of electrode that consists of a stainless-steel shaft and an array of polyimide based high density electrodes that are embedded onto this shaft. This type of electrode design has proven highly reliable for deep brain penetrations of up to of up to 8cm length in rodent and non-human primate. The steel carrier is highly robust, entirely avoiding the breakage problems associated with silicon based and other high-density probe designs. Similarly, the polyimide-based electrodes are a material that is well known to not be biotoxic, which is well tolerated and part of numerous currently FDA approved products. The DBC Deep Array electrode is wired directly to an Intan (Los Angeles, CA) microprocessor mounted at the other end of the shaft. This microprocessor generates a digital signal, so that a long connection can be utilized between the microprocessor and Intan amplifier unit used to record the data, without any loss in signal or addition of noise. This feature is crucial to improve patient safety and reduce any infection risks during recording. Steel is rigid, and not prone to fracture like silicon. In addition, this type of electrode can be made significantly longer, simply by using a longer stainless-steel shaft to mount the high-density polyimide array on. While the currently manufactured DBC deep arrays used in animal research are 40-80 mm in length, a length of up to 300 mm is easily feasible. This contrasts with the maximal 10 -20 mm length that is achievable for silicon-based and other high-density systems. A length of >100mm is required for probing deep brain structures such as the basal ganglia in the human brain, which is routinely done in clinical settings. The DBC electrode can record up to 1024 individual channels simultaneously. The DBC devices have been used successfully in nonhuman primates and have undergone the biocompatibility, cytotoxicity, sterilization, and safety testing expected for use in humans. The results of these tests were all a pass, and the resulting reports are attached to this protocol.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Parkinson Disease, Idiopathic
Keywords
Parkinson's, DBS, Electrode

7. Study Design

Primary Purpose
Basic Science
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
10 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
Neuronal Recording and Behavioral Testing
Arm Type
Experimental
Arm Description
Neuronal Recording and Behavioral Testing
Intervention Type
Device
Intervention Name(s)
DBC (Diagnostic Biochips) Deep Array microelectrode; Intan Electrophysiology recording system; Matlab response recording to behavioral task
Intervention Description
Devices listed are components of a single intervention that includes: Record neuronal activity (Intan) from electrodes (DBC), record and analyze patient responses (Matlab)
Primary Outcome Measure Information:
Title
Neuronal Activity
Description
Single Neuron firing rate (spikes) measured in spikes per second - total number of isolated neurons, amplitude (in uV of spikes) - by Intan Neurophysiology Recording System
Time Frame
One week after recording in OR completed
Title
Breakage of Electrode
Description
Extent of fracture of electrode tip measured in micrometers by a light microscope
Time Frame
One week after recording in OR completed

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Any patient undergoing implantation of a Deep Brain Stimulating (DBS) electrode in the Subthalamic nucleus (STN) for the treatment of Parkinson's disease, in whom microelectrode recording is being performed to improve localization of the STN. Age > 18 years of age Able to give independent informed consent Exclusion Criteria: Microelectrode recording is not indicated Previous implantation of DBS electrodes in this site Known allergic reaction to stainless steel or polyimide
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Mia Coordinator
Phone
4243152642
Email
mazerm@cshs.org
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Adam Mamelak, MD
Organizational Affiliation
Cedars-Sinai Medical Center
Official's Role
Principal Investigator
Facility Information:
Facility Name
Cedars-Sinai Medical Center
City
Los Angeles
State/Province
California
ZIP/Postal Code
90048
Country
United States

12. IPD Sharing Statement

Plan to Share IPD
No

Learn more about this trial

A High-density Microelectrode for Human Neuronal Recordings

We'll reach out to this number within 24 hrs