search
Back to results

A Prospective Multicenter Cohort Study About Internal Fixation Using FNS Versus MCS for Femoral Neck Fracture

Primary Purpose

Femoral Neck Fractures

Status
Recruiting
Phase
Not Applicable
Locations
China
Study Type
Interventional
Intervention
FNS
MCS
Sponsored by
Peking University Third Hospital
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Femoral Neck Fractures focused on measuring femoral neck fracture, internal fixation, FNS and MCS, multicenter randomized controlled clinical trial, internal fixation failure rate

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. Age ≥18 years
  2. Patients with unilateral femoral neck fractures that will be treated with internal fixation
  3. According to AO fracture classification, subjects with the fracture type (31-B)
  4. Subjects (with the help of relatives) can understand the informed documents and patient questionnaires.
  5. Subjects (with the help of relatives) voluntarily provide written informed consent to participate in the clinical study and authorize the transfer of their information to the sponsor.
  6. The investigator believes that the subject can understand the clinical study, is willing and able to complete all research procedures and follow-up visits and can cooperate with the research procedures.
  7. In-label use of the MCS and FNS.

Exclusion Criteria:

  1. Subject does not provide voluntary consent to participate in the study.
  2. The researcher believes that the subjects have conditions that affect the participation and follow-up of this study. (for example, the patient lives in a remote area or has difficulty in going back to the hospital for follow-up or does not cooperate with the medical guidance and suggestions of the surgeon.)
  3. The subjects were pregnant or lactating women.
  4. The researchers believe that the subjects have psychological disorders, which may affect the treatment outcome.
  5. Garden classification III and IV of femoral neck fracture patients older than 65 years
  6. Concurrent hip osteoarthritis.
  7. Fractures where the operative treatment will occur more than three weeks after the primary injury
  8. Patients combined with other bone fractures.
  9. Pathological fracture (e.g., primary or metastatic tumor)
  10. Serious soft tissue injury, judged by the investigator, will impact the union of the fracture, combined open fractures, vascular injury, and combined osteofascial compartment syndrome
  11. Multiple systemic injuries judged by researchers not suitable for enrollment.
  12. Revision surgeries (for example, due to malunion, nonunion or infection)
  13. Concurrent medical conditions judged by researchers not suitable for enrollment, such as: metabolic bone disease, post-polio syndrome, poor bone quality, prior history of poor fracture healing, etc
  14. Patients with anaesthetic and surgical contraindications
  15. Patients known to be allergic to implant components
  16. Patients who are currently using chemotherapeutics or accepting radiotherapy, use systematically corticosteroid hormone or growth factor, or long-term use sedative hypnotics (continuous use over 3 months) or non-steroidal anti-inflammatory drugs (continuous use over 3 months)
  17. Intemperance judged by researchers not suitable for enrollment (e.g., excessive daily drinking or smoking, drug abuse);
  18. Subjects participated in other clinical studies in the past 3 months, which may affect the outcome and follow-up according to the judgment of researchers.
  19. Subjects have significant neurological or musculoskeletal disorders or may have adverse effects on gait or weight-bearing (e.g., muscular dystrophy, multiple sclerosis, cerebral infarction, hemiplegia, Charcot arthropathy, avascular necrosis of the femoral head).

Sites / Locations

  • Peking University Third HospitalRecruiting

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

Synthes Femoral Neck System (FNS)

Multiple cancellous screws (MCS)

Arm Description

Synthes Femoral Neck System (FNS) was developed with the intention to combine advantages of DHS (dynamic hip screw) and MCS (multiple cancellous screw). The FNS implants consist of plates, bolts, locking screws and antirotating-screws. The plate consists of a small base plate with one or two locking holes and a barrel portion. The barrel allows for gliding of the head elements while restricting rotation around the head-neck axis, so FNS is a fixed-angle gliding fixation device that allows for controlled collapse of the femoral neck, like DHS. The FNS was also designed to minimize implant footprint on the bone with its compact design, like MCS. Furthermore, the FNS was designed to reduce the length of incision necessary for implant insertion when compared to DHS. This new concept of femoral neck fracture fixation still emphasizes the biology of fracture healing by initial fracture compression.

Multiple cancellous screws (MCS) fixation is the most common and classic method to deal with femoral neck fractures which is less invasive and retains more viable bone, compared with dynamic hip screw (DHS) fixation that appears biomechanically more stable. In this study, three cancellous screws with an inverted triangle pattern are used to fix the fracture of femoral neck.

Outcomes

Primary Outcome Measures

Internal fixation failure rate
defined as the total incidence of internal plant cut-out and fracture.

Secondary Outcome Measures

Number of Participants with Bone nonunion
evaluate bone healing according to the lateral X-ray examination. According to the regulations of Food and Drug Administration of the US, if there are no obvious signs of fracture healing 9 months after the fracture, or if there is no obvious difference in fracture space after three consecutive months, it is defined as nonunion.
Harris hip score
the score value is from 0 to 100, and a higher score means a better outcome
operation time
from the incision to internal fixation implanted.
The times of intraoperative fluoroscopy
average 25 milliseconds per X-ray shot, record the number of X-ray shot
Number of Participants with Postoperative adverse events
including ipsilateral femoral head avascular necrosis, infection, wound hematoma, ipsilateral coxa vara, and ipsilateral limb shortening
Garden index
The fracture reduction will be considered unsatisfied if the index is less than 155 degrees or more than 180 degrees.
A 12-Item Short-Form Health Survey (SF-12)
the score value is from 0 to 100, and a higher score means a better outcome

Full Information

First Posted
June 28, 2020
Last Updated
October 20, 2021
Sponsor
Peking University Third Hospital
Collaborators
Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University, Beijing Jishuitan Hospital, Shanghai 6th People's Hospital, Tianjin Hospital, The Fuzhou No 2 Hospital, Xi'an Honghui Hospital, West China Hospital
search

1. Study Identification

Unique Protocol Identification Number
NCT04462172
Brief Title
A Prospective Multicenter Cohort Study About Internal Fixation Using FNS Versus MCS for Femoral Neck Fracture
Official Title
A Prospective Multicenter Cohort Study About Internal Fixation Using Synthes Femoral Neck System (FNS) Versus Multiple Cancellous Screws (MCS) for Femoral Neck Fracture
Study Type
Interventional

2. Study Status

Record Verification Date
June 2021
Overall Recruitment Status
Recruiting
Study Start Date
September 30, 2021 (Actual)
Primary Completion Date
September 30, 2024 (Anticipated)
Study Completion Date
December 31, 2024 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Peking University Third Hospital
Collaborators
Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University, Beijing Jishuitan Hospital, Shanghai 6th People's Hospital, Tianjin Hospital, The Fuzhou No 2 Hospital, Xi'an Honghui Hospital, West China Hospital

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Product Manufactured in and Exported from the U.S.
Yes

5. Study Description

Brief Summary
This prospective multicenter cohort study is to compare the post-operative implant failure rate between the patients with femoral neck fracture (AO classification 31-B) using Femoral Neck System (FNS) versus Multiple Cancellous Screws (MCS) at 2-year follow up. The patients are divided into the FNS group and the MCS group according to the internal fixation they choose. The internal fixation failure rate (IFFR) and differences in fracture prognosis of the two groups will be compared. Obtain clinical data of FNS in the Chinese population, and verify the safety and efficacy of FNS for patients with femoral neck fracture.
Detailed Description
This is a prospective multicenter cohort study. The team leader is Peking University Third Hospital. All patients are divided into 2 groups according to the internal fixation they choose. Investigators use FNS for internal fixation in Group 1 and MCS in Group 2. Since FNS is clinically comparable to the Dynamic Hip Screw (DHS) system, investigators used DHS clinical data as a statistical reference. The relevant parameters of the sample calculation are α = 0.05 (one-sided) and β = 0.2. PASS 15 was used for calculation, and the final sample size was 290. The FNS group and the MCS group each included 145 patients. See the text for detailed inclusion and exclusion criteria. Patients that meet all the inclusion criteria but do not meet any exclusion criteria, and who have signed the informed consent will be recruited, and each patient will be assigned a unique patient identification number, which will be used throughout the study identify the patient. Investigators will perform preoperative preparation, intraoperative operation and internal fixation implantation according to the instructions provided in the product packaging. Investigators only plan to include cases that can successfully conduct closed reduction, therefore investigators will exclude cases that require open reduction. For the MCS group, three cancellous screws with an inverted triangle pattern are used to fix the fracture of femoral neck. After the operation, the patients will be managed according to the standard nursing and rehabilitation procedures of the experimental site and the results of laboratory tests will be recorded. Regular follow-up evaluation will be performed after the operation until the end of the two-year follow-up or the primary end point of the study. In this study, the internal fixation failure rate (IFFR) is used as the primary end point of the study, which is defined as the total incidence of internal plant cut-out and fracture. The results of the radiographic examination, the lateral X-ray film and computed tomography(CT), will be evaluated by an independent radiologist to determine whether there are cut-out or fracture of the internal plant. Secondary endpoints include: 1. Bone nonunion after 36 weeks: evaluate bone healing according to the lateral X-ray examination. According to the regulations of Food and Drug Administration of the US, it is defined as nonunion if there are no obvious signs of fracture healing 9 months after the fracture, or if there is no obvious difference in fracture space after three consecutive months. 2. Garden classification proportion, and Garden index for reduction assessment. 3. Clinical prognosis: o A 12-Item Short-Form Health Survey (SF-12) o Harris hip score. 4. Operation time, from the incision to internal fixation implanted. 5. The times of intraoperative fluoroscopy, average 25 milliseconds per X-ray shot, record the number of X-ray shot. 6. Postoperative adverse events within 2 years, including ipsilateral femoral head avascular necrosis, infection, wound hematoma, ipsilateral coxa vara, and ipsilateral limb shortening. In this study, it is difficult to blind anyone . Investigators will try their best to reduce human-induced bias in experimental results. Investigators will use one-sided α = 0.05 for statistical tests and confidence interval calculations. P value <0.05 is considered statistically significant. SPSS (latest version: SPSS Inc., Chicago, IL, USA) will be used to analyze the results.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Femoral Neck Fractures
Keywords
femoral neck fracture, internal fixation, FNS and MCS, multicenter randomized controlled clinical trial, internal fixation failure rate

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Model Description
This prospective multicenter cohort study is to compare the post-operative implant failure rate between the patients with femoral neck fracture (AO classification 31-B) using Femoral Neck System (FNS) versus Multiple Cancellous Screws (MCS) at 2-year follow up.The patients are divided into the FNS group and the MCS group according to the internal fixation they choose.
Masking
None (Open Label)
Allocation
Non-Randomized
Enrollment
290 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
Synthes Femoral Neck System (FNS)
Arm Type
Experimental
Arm Description
Synthes Femoral Neck System (FNS) was developed with the intention to combine advantages of DHS (dynamic hip screw) and MCS (multiple cancellous screw). The FNS implants consist of plates, bolts, locking screws and antirotating-screws. The plate consists of a small base plate with one or two locking holes and a barrel portion. The barrel allows for gliding of the head elements while restricting rotation around the head-neck axis, so FNS is a fixed-angle gliding fixation device that allows for controlled collapse of the femoral neck, like DHS. The FNS was also designed to minimize implant footprint on the bone with its compact design, like MCS. Furthermore, the FNS was designed to reduce the length of incision necessary for implant insertion when compared to DHS. This new concept of femoral neck fracture fixation still emphasizes the biology of fracture healing by initial fracture compression.
Arm Title
Multiple cancellous screws (MCS)
Arm Type
Active Comparator
Arm Description
Multiple cancellous screws (MCS) fixation is the most common and classic method to deal with femoral neck fractures which is less invasive and retains more viable bone, compared with dynamic hip screw (DHS) fixation that appears biomechanically more stable. In this study, three cancellous screws with an inverted triangle pattern are used to fix the fracture of femoral neck.
Intervention Type
Device
Intervention Name(s)
FNS
Intervention Description
perform preoperative preparation, intraoperative operation and internal fixation implantation according to the instructions provided in the product packaging.
Intervention Type
Device
Intervention Name(s)
MCS
Intervention Description
three cancellous screws with an inverted triangle pattern are used to fix the fracture of femoral neck.
Primary Outcome Measure Information:
Title
Internal fixation failure rate
Description
defined as the total incidence of internal plant cut-out and fracture.
Time Frame
from operation to 2-year follow-up after the surgery
Secondary Outcome Measure Information:
Title
Number of Participants with Bone nonunion
Description
evaluate bone healing according to the lateral X-ray examination. According to the regulations of Food and Drug Administration of the US, if there are no obvious signs of fracture healing 9 months after the fracture, or if there is no obvious difference in fracture space after three consecutive months, it is defined as nonunion.
Time Frame
from operation to 2-year follow-up after the surgery
Title
Harris hip score
Description
the score value is from 0 to 100, and a higher score means a better outcome
Time Frame
from operation to 2-year follow-up after the surgery
Title
operation time
Description
from the incision to internal fixation implanted.
Time Frame
intraoperative
Title
The times of intraoperative fluoroscopy
Description
average 25 milliseconds per X-ray shot, record the number of X-ray shot
Time Frame
intraoperative
Title
Number of Participants with Postoperative adverse events
Description
including ipsilateral femoral head avascular necrosis, infection, wound hematoma, ipsilateral coxa vara, and ipsilateral limb shortening
Time Frame
from operation to 2-year follow-up after the surgery
Title
Garden index
Description
The fracture reduction will be considered unsatisfied if the index is less than 155 degrees or more than 180 degrees.
Time Frame
from operation to 2-year follow-up after the surgery
Title
A 12-Item Short-Form Health Survey (SF-12)
Description
the score value is from 0 to 100, and a higher score means a better outcome
Time Frame
from operation to 2-year follow-up after the surgery

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Age ≥18 years Patients with unilateral femoral neck fractures that will be treated with internal fixation According to AO fracture classification, subjects with the fracture type (31-B) Subjects (with the help of relatives) can understand the informed documents and patient questionnaires. Subjects (with the help of relatives) voluntarily provide written informed consent to participate in the clinical study and authorize the transfer of their information to the sponsor. The investigator believes that the subject can understand the clinical study, is willing and able to complete all research procedures and follow-up visits and can cooperate with the research procedures. In-label use of the MCS and FNS. Exclusion Criteria: Subject does not provide voluntary consent to participate in the study. The researcher believes that the subjects have conditions that affect the participation and follow-up of this study. (for example, the patient lives in a remote area or has difficulty in going back to the hospital for follow-up or does not cooperate with the medical guidance and suggestions of the surgeon.) The subjects were pregnant or lactating women. The researchers believe that the subjects have psychological disorders, which may affect the treatment outcome. Garden classification III and IV of femoral neck fracture patients older than 65 years Concurrent hip osteoarthritis. Fractures where the operative treatment will occur more than three weeks after the primary injury Patients combined with other bone fractures. Pathological fracture (e.g., primary or metastatic tumor) Serious soft tissue injury, judged by the investigator, will impact the union of the fracture, combined open fractures, vascular injury, and combined osteofascial compartment syndrome Multiple systemic injuries judged by researchers not suitable for enrollment. Revision surgeries (for example, due to malunion, nonunion or infection) Concurrent medical conditions judged by researchers not suitable for enrollment, such as: metabolic bone disease, post-polio syndrome, poor bone quality, prior history of poor fracture healing, etc Patients with anaesthetic and surgical contraindications Patients known to be allergic to implant components Patients who are currently using chemotherapeutics or accepting radiotherapy, use systematically corticosteroid hormone or growth factor, or long-term use sedative hypnotics (continuous use over 3 months) or non-steroidal anti-inflammatory drugs (continuous use over 3 months) Intemperance judged by researchers not suitable for enrollment (e.g., excessive daily drinking or smoking, drug abuse); Subjects participated in other clinical studies in the past 3 months, which may affect the outcome and follow-up according to the judgment of researchers. Subjects have significant neurological or musculoskeletal disorders or may have adverse effects on gait or weight-bearing (e.g., muscular dystrophy, multiple sclerosis, cerebral infarction, hemiplegia, Charcot arthropathy, avascular necrosis of the femoral head).
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Xiangyu Xu, MD
Phone
+86-15210849431
Email
307542744@qq.com
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Fang Zhou, MD
Organizational Affiliation
Peking University Third Hospital
Official's Role
Study Director
Facility Information:
Facility Name
Peking University Third Hospital
City
Beijing
State/Province
Beijing
ZIP/Postal Code
100191
Country
China
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Fang Zhou, MD
Phone
+8610-82267010
Email
zhouf@bjmu.edu.cn
First Name & Middle Initial & Last Name & Degree
Xiangyu Xu, MD
Phone
+86-15210849431
Email
307542744@qq.com

12. IPD Sharing Statement

Plan to Share IPD
No

Learn more about this trial

A Prospective Multicenter Cohort Study About Internal Fixation Using FNS Versus MCS for Femoral Neck Fracture

We'll reach out to this number within 24 hrs