A Randomized Clinical Trial of Brace Treatment
Primary Purpose
Scoliosis; Idiopathic, Infantile
Status
Suspended
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
Active Brace system
Sponsored by
About this trial
This is an interventional treatment trial for Scoliosis; Idiopathic, Infantile focused on measuring Orthotic treatment, Ultrasound Imaging
Eligibility Criteria
Inclusion Criteria:
- age 10 - 16 years
- diagnosed of AIS
- require full-time brace wear
- have Cobb angle between 20° - 40°
- have Risser sign ≤3
- premenarchal or less than 1 year postmenarchal.
Exclusion Criteria:
- patients who require surgery
- presenting with associated musculoskeletal, neurological or other conditions possibly responsible for the curvature
- physical or mental disability that prevent patients from complying with the bracing protocol
Sites / Locations
Arms of the Study
Arm 1
Arm 2
Arm Type
Active Comparator
Active Comparator
Arm Label
Monitor Only
Active Brace System
Arm Description
A brace monitor will be embedded inside the brace to monitor compliance.
An active brace device will be embedded inside the brace to dynamically control interface pressure and monitor compliance.
Outcomes
Primary Outcome Measures
Effectiveness of active brace treatment
The proportions of successful treatment between two arms b to determine the overall effectiveness
Immediate Active effect
Review the out of brace Cobb angle 1 year after using the spinal brace
Secondary Outcome Measures
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT03022656
Brief Title
A Randomized Clinical Trial of Brace Treatment
Official Title
A Randomized Clinical Trial of Brace Treatment
Study Type
Interventional
2. Study Status
Record Verification Date
May 2023
Overall Recruitment Status
Suspended
Why Stopped
COVID Pandemic
Study Start Date
January 2017 (Actual)
Primary Completion Date
December 2024 (Anticipated)
Study Completion Date
December 2024 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University of Alberta
4. Oversight
Data Monitoring Committee
No
5. Study Description
Brief Summary
Brace treatment is the most effective non-surgical method for the treatment of Adolescent idiopathic scoliosis (AIS). The goal of bracing is to stop the curve progression during the high risk period of the adolescent growth spurt. A spinal brace is a hard plastic shell with pressure pads installed inside the liner to provide mechanical support to the curvature of the spine. It is a big commitment for adolescents to wear a brace because it is physically restrictive, uncomfortable and draws unwanted attention. Therefore, it is very important to make the brace treatment as effective as possible to get patient buy-in to compromise their lifestyle by wearing a brace. Patients' belief in the treatment outcomes is also a factor to attain their compliance.
This randomized clinical study will investigate if the effectiveness of brace treatment can be maximized by combining ultrasound imaging assistance during brace design with the smart brace to automatically maintain corrective brace pressures at the optimum level during the whole treatment period.
Detailed Description
Background: Brace treatment is the most effective non-surgical method for the treatment of AIS. The goal of bracing is to stop the curve progression during the high risk period of the adolescent growth spurt. A spinal brace is a hard plastic shell with pressure pads installed inside the liner to provide mechanical support to the curvature of the spine. It is a big commitment for adolescents to wear a brace because it is physically restrictive, uncomfortable and draws unwanted attention. Therefore, it is very important to make the brace treatment as effective as possible to get patient buy-in to compromise their lifestyle by wearing a brace. Patients' belief in the treatment outcomes is also a factor to attain their compliance.
Study Objective: This randomized clinical study will investigate if the effectiveness of brace treatment can be maximized by combining ultrasound imaging assistance during brace design with the smart brace to automatically maintain corrective brace pressures at the optimum level during the whole treatment period.
Methodology:
Subject Selection: One hundred and twenty-eight brace candidates with AIS will be recruited over the next 5 years. During the scoliosis clinic, the attending orthopaedic surgeon identifies a potential candidate. He will ask the potential patient if he/she is interested in speaking with the research coordinator about research projects that he/she is eligible. The inclusion criteria are patients 1) age 10 - 16 years, 2) diagnosis of AIS, 3) require full-time brace wear, 4) Cobb angle between 20° - 40°, 5) Risser sign ≤3 and 6) premenarchal or less than 1 year postmenarchal. Subjects will be randomly selected to 1 of the 2 groups: a) An ultrasound assisted designed brace and a brace monitor, and b) An ultrasound assisted designed brace and a smart brace device. Figure 1 shows the flow chart of the study. Each subject will have 50% chance of being in any one of the groups. An extra 15 minutes will be needed for both groups during the brace fitting clinic to install the brace monitor or smart brace device. An extra 30 minutes will be added to your casting. Participants will be monitored until the brace treatment is finished.
Detailed description: The brace monitor is a small electronic device which will be embedded inside the brace. It is a very low power system operating at 3.3 V and 2 milliampere (mA) (on average). It is able to store 12 months of data and the battery can last for 9 months. It will record how much time and how tightly the subject wears the brace. The brace with the monitor looks exactly the same as a standard brace. The subject won't feel any different and don't need to do anything beyond. We will replace the monitor with a new one at every standard follow up clinic.
A smart brace device is a small electronic device. It will have a small air bag embedded at the major pad area covered with stretchable leather. It will record how much time and how tightly the brace is worn. The air bag will inflate if the contact pressure between the brace and the body is lower than expected. The air bag will deflate if the contact pressure between the brace and the body is higher than expected. This automatic pressure adjustment will only be activated during daytime which is individualized based on the patient's sleep pattern. The system will also be activated only if breathing motion is detected (which means brace is worn). The smart brace monitor is able to store 6 months of data but requiring to recharge every day for 30 minutes. The smart brace monitor is a low power system (operating at 4.2 V and 150 mA max). It has an on-off switch and a pressure enable-disable regulation switch safety functions. Switching enable-disable regulation to off will make the smart brace device becomes a standard brace monitor. Turing off the on-off switch will disable all the functions and this brace will become a standard brace. We will replace the monitor with a new one at every standard follow up clinic.
The ultrasound assisted design requires to get 4 ultrasound images: normal standing, normal supine, bending left supine and bending right supine. Each scan takes approximately 1 minute. These 4 scans will provide spine flexibility information. After this, the subject will be asked to stand in a wooden positioning frame with pressure pads allow to move 3-dimensionally. Multiple adjustable brace pads will be applied to the patients' body according to orthotist suggestion. An ultrasound scan will be performed after the pads are applied. The orthotist will use the ultrasound image to decide if the pads are at the optimum locations and applied proper pressures. If the orthotist is satisfied with the correction, he/ she will use this setup to build the brace. Otherwise, he/she will adjust the position and orientation of the pads and repeated the ultrasound scan.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Scoliosis; Idiopathic, Infantile
Keywords
Orthotic treatment, Ultrasound Imaging
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
128 (Anticipated)
8. Arms, Groups, and Interventions
Arm Title
Monitor Only
Arm Type
Active Comparator
Arm Description
A brace monitor will be embedded inside the brace to monitor compliance.
Arm Title
Active Brace System
Arm Type
Active Comparator
Arm Description
An active brace device will be embedded inside the brace to dynamically control interface pressure and monitor compliance.
Intervention Type
Device
Intervention Name(s)
Active Brace system
Primary Outcome Measure Information:
Title
Effectiveness of active brace treatment
Description
The proportions of successful treatment between two arms b to determine the overall effectiveness
Time Frame
2 years after completing the brace treatment
Title
Immediate Active effect
Description
Review the out of brace Cobb angle 1 year after using the spinal brace
Time Frame
1 year after enrollment
10. Eligibility
Sex
All
Minimum Age & Unit of Time
10 Years
Maximum Age & Unit of Time
16 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
age 10 - 16 years
diagnosed of AIS
require full-time brace wear
have Cobb angle between 20° - 40°
have Risser sign ≤3
premenarchal or less than 1 year postmenarchal.
Exclusion Criteria:
patients who require surgery
presenting with associated musculoskeletal, neurological or other conditions possibly responsible for the curvature
physical or mental disability that prevent patients from complying with the bracing protocol
12. IPD Sharing Statement
Learn more about this trial
A Randomized Clinical Trial of Brace Treatment
We'll reach out to this number within 24 hrs