Geometric Mean Concentration of Antibodies to Polyribosylribitol Phosphate Antigen
Participant serum samples were collected for testing with a radioimmunoassay for antibodies to Haemophilus influenza type b capsular polysaccharide polyribosylribitol phosphate.
Geometric Mean Concentration of Antibodies to Hepatitis B Surface Antigen
Participant serum samples were collected for testing with an enhanced chemiluminescence assay for antibodies to Hepatitis B Surface Antigen. The unit of measure is milli International Units/mL (mIU/mL).
Geometric Mean Concentration of Antibodies to Diphtheria Toxin
Participant serum samples were collected for testing with a Micrometabolic Inhibition Test for neutralizing antibodies to diphtheria toxin. The unit of measure is International Units/mL (IU/mL).
Geometric Mean Concentration of Antibodies to Tetanus Toxin
Participant serum samples were collected for testing with an Enzyme-linked Immunosorbent Assay (ELISA) for anti-tetanus antibodies.
Geometric Mean Concentration of Antibodies to Pertussis Toxin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis toxin. The unit of measure is ELISA units/mL (EU/mL).
Geometric Mean Concentration of Antibodies to Pertussis Filamentous Hemagglutinin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis filamentous hemagglutinin.
Geometric Mean Concentration of Antibodies to Pertussis Pertactin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis pertactin.
Geometric Mean Concentration of Antibodies to Pertussis Fimbriae
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis fimbriae.
Geometric Mean Titer for Antibodies to Poliovirus Type 1
Participant serum samples were collected for testing with a Micrometabolic Inhibition Test for neutralizing antibodies to Poliovirus Type 1. The unit of measure is titer (reciprocal of highest dilution with neutralizing activity).
Geometric Mean Titer for Antibodies to Poliovirus Type 2
Participant serum samples were collected for testing with a Micrometabolic Inhibition Test for neutralizing antibodies to Poliovirus Type 2.
Geometric Mean Titer for Antibodies to Poliovirus Type 3
Participant serum samples were collected for testing with a Micrometabolic Inhibition Test for neutralizing antibodies to Poliovirus Type 3.
Percentage of Participants Responding to Polyribosylribitol Phosphate Antigen
Participant serum samples were collected for testing with a radioimmunoassay for antibodies to Haemophilus influenza type b capsular polysaccharide polyribosylribitol phosphate. Response was evaluated for a titer >=0.15 µg/mL and >=1.0 µg/mL.
Percentage of Participants Responding to Hepatitis B Surface Antigen
Participant serum samples were collected for testing with an enhanced chemiluminescence assay for antibodies to Hepatitis B Surface Antigen. Response was defined as a titer >=10 mIU/mL.
Percentage of Participants Responding to Diphtheria Toxin
Participant serum samples were collected for testing with a Micrometabolic Inhibition Test for neutralizing antibodies to diphtheria toxin. Response was defined as a titer >=0.1 IU/mL.
Percentage of Participants Responding to Tetanus Toxin
Participant serum samples were collected for testing with an ELISA for anti-tetanus antibodies. Response was defined as a titer >=0.1 IU/mL.
Percentage of Participants Responding to Pertussis Toxin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis toxin. Response was defined as follows: 1) if the predose titer was <4 times the lower limit of quantitation (4X LLOQ) then the postdose titer was >=4X LLOQ; 2) if the predose titer was >=4X LLOQ then the postdose titer was >= the predose titer.
Percentage of Participants Responding to Pertussis Filamentous Hemagglutinin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis filamentous hemagglutinin. Response was defined as follows: 1) if the predose titer was <4X LLOQ then the postdose titer was >=4X LLOQ; 2) if the predose titer was >=4X LLOQ then the postdose titer was >= the predose titer.
Percentage of Participants Responding to Pertussis Pertactin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis pertactin. Response was defined as follows: 1) if the predose titer was <4X LLOQ then the postdose titer was >=4X LLOQ; 2) if the predose titer was >=4X LLOQ then the postdose titer was >= the predose titer.
Percentage of Participants Responding to Pertussis Fimbriae
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis fimbriae. Response was defined as follows: 1) if the predose titer was <4X LLOQ then the postdose titer was >=4X LLOQ; 2) if the predose titer was >=4X LLOQ then the postdose titer was >= the predose titer.
Percentage of Participants Responding to Poliovirus Type 1
Participant serum samples were collected for testing with a Micrometabolic Inhibition Test for neutralizing antibodies to Poliovirus Type 1. Response is defined as a titer >=8.
Percentage of Participants Responding to Poliovirus Type 2
Participant serum samples were collected for testing with a Micrometabolic Inhibition Test for neutralizing antibodies to Poliovirus Type 2. Response is defined as a titer >=8.
Percentage of Participants Responding to Poliovirus Type 3
Participant serum samples were collected for testing with a Micrometabolic Inhibition Test for neutralizing antibodies to Poliovirus Type 3. Response is defined as a titer >=8.
Geometric Mean Concentration of Antibodies to Pertussis Toxin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis toxin. Analysis for this outcome included only non-inferiority of V419 Lots A, B, and C Combined versus Control.
Geometric Mean Concentration of Antibodies to Pertussis Filamentous Hemagglutinin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis filamentous hemagglutinin. Analysis for this outcome included only non-inferiority of V419 Lots A, B, and C Combined versus Control.
Geometric Mean Concentration of Antibodies to Pertussis Pertactin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis pertactin. Analysis for this outcome included only non-inferiority of V419 Lots A, B, and C Combined versus Control.
Geometric Mean Concentration of Antibodies to Pertussis Fimbriae
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis fimbriae. Analysis for this outcome included only non-inferiority of V419 Lots A, B, and C Combined versus Control.
Percentage of Participants Responding to Pertussis Toxin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis toxin. Response was defined as follows: 1) if the predose titer was <4X LLOQ then the postdose titer was >=4X LLOQ; 2) if the predose titer was >=4X LLOQ then the postdose titer was >= the predose titer. Analysis for this outcome included only non-inferiority of V419 Lots A, B, and C Combined versus Control.
Percentage of Participants Responding to Pertussis Filamentous Hemagglutinin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis filamentous hemagglutinin. Response was defined as follows: 1) if the predose titer was <4X LLOQ then the postdose titer was >=4X LLOQ; 2) if the predose titer was >=4X LLOQ then the postdose titer was >= the predose titer. Analysis for this outcome included only non-inferiority of V419 Lots A, B, and C Combined versus Control.
Percentage of Participants Responding to Pertussis Pertactin
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis pertactin. Response was defined as follows: 1) if the predose titer was <4X LLOQ then the postdose titer was >=4X LLOQ; 2) if the predose titer was >=4X LLOQ then the postdose titer was >= the predose titer. Analysis for this outcome included only non-inferiority of V419 Lots A, B, and C Combined versus Control.
Percentage of Participants Responding to Pertussis Fimbriae
Participant serum samples were collected for testing with an ELISA for antibodies to pertussis fimbriae. Response was defined as follows: 1) if the predose titer was <4X LLOQ then the postdose titer was >=4X LLOQ; 2) if the predose titer was >=4X LLOQ then the postdose titer was >= the predose titer. Analysis for this outcome included only non-inferiority of V419 Lots A, B, and C Combined versus Control.
Geometric Mean Concentration of Antibodies to Pneumococcal Serotypes
Participant serum samples were collected for testing with a multiplex electrochemiluminescence-based detection assay for serotype-specific pneumococcal polysaccharide antibodies. Analysis for this outcome included only non-inferiority of V419 Lots A, B, and C Combined versus Control.
Percentage of Participants Reporting Solicited Injection-site or Systemic Reactions
Solicited injection site reactions: Pain, Erythema, and Swelling. Solicited systemic reactions: Fever, Vomiting, Crying abnormal, Drowsiness, Appetite lost, and Irritability. Grade 3 Solicited injection site reaction: Pain, Cries when injected limb is moved or the movement of the injected limb is reduced; Erythema and Swelling, >5 cm. Grade 3 Solicited systemic reactions: Fever (Pyrexia), >=39.5°C rectal; Vomiting, >=6 episodes per 24 hours or requiring parenteral hydration; Crying abnormal, >3 hours; Drowsiness (Somnolence), Sleeping most of the time or difficult to wake up; Appetite lost, Refuses >=3 feeds or refuses most feeds; Irritability, Inconsolable.
Percentage of Participants With Elevated Temperature by Severity
Maximum temperature (all routes) was based on actual temperatures recorded with no adjustments to the measurement route. Maximum temperature (rectal) was required of all participants if the reading by another method was >=38.0°C.