search
Back to results

Artificial Pancreas Control System in an Inpatient Setting

Primary Purpose

Type I Diabetes Mellitus

Status
Completed
Phase
Phase 2
Locations
United States
Study Type
Interventional
Intervention
Artificial Pancreas Control Software
Sponsored by
Legacy Health System
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Type I Diabetes Mellitus focused on measuring glucose sensors, artificial pancreas, Diabetes Mellitus

Eligibility Criteria

21 Years - 65 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Diagnosis of type 1 diabetes mellitus for at least 1 year.
  • Male or female subjects 21 to 65 years of age.
  • Current use of an insulin pump.
  • Willingness to follow all study procedures, including attending all clinic visits.
  • Willingness to sign informed consent and HIPAA documents.

Exclusion Criteria:

  • Pregnancy or Lactation: For women of childbearing potential: there is a requirement for a negative urine pregnancy test and for agreement to use contraception during the study and for at least 1 month after participating in the study. Acceptable contraception includes birth control pill / patch / vaginal ring, Depo-Provera, Norplant, an IUD, the double barrier method (the woman uses a diaphragm and spermicide and the man uses a condom), or abstinence.
  • Renal insufficiency (serum creatinine of 2.0 mg/dL or greater).
  • Serum ALT or AST equal to or greater than 3 times the upper limit of normal; hepatic synthetic insufficiency as defined as a serum albumin of less than 3.3 g/dL; or serum bilirubin of over 2.
  • Adrenal insufficiency
  • Hematocrit of less than or equal to 34%.
  • A history of cerebrovascular disease or coronary artery disease regardless of the time since occurrence.
  • Congestive heart failure, NYHA class III or IV.
  • Diagnosis of 2nd or 3rd degree heart block or any arrhythmia judged by the investigator to be exclusionary.
  • Any active infection.
  • Visual impairment preventing reading of glucose meter values or continuous glucose monitoring device.
  • Physical impairment impeding the ability to use a glucose meter or glucose monitoring device.
  • Active foot ulceration.
  • Severe peripheral arterial disease characterized by ischemic rest pain or severe claudication.
  • Active alcohol abuse, substance abuse, or severe mental illness (as judged by the principal investigator).
  • Active malignancy, except basal cell or squamous cell skin cancers.
  • Major surgical operation within 30 days prior to screening.
  • Seizure disorder.
  • Chronic usage of any immunosuppressive medication (such as cyclosporine, azathioprine, sirolimus, or tacrolimus).
  • Current administration of oral or parenteral corticosteroids.
  • Use of an investigational drug within 30 days prior to screening.
  • Bleeding disorder, treatment with warfarin, or platelet count below 50,000.
  • Allergy to aspart insulin.
  • Allergy to glucagon.
  • Past history of pheochromocytoma or a family history of MEN 2, neurofibromatosis, or von Hippel-Lindau disease.
  • Insulin resistance requiring more than 200 units per day.
  • Need for uninterrupted treatment of acetaminophen.
  • Intolerance of mild hypoglycemia (glucose 60-70 mg/dl).
  • History of hypoglycemic unawareness.
  • Insulin antibody level of ≥ 100 µUnits/ml.
  • C peptide level of ≥0.5 ng/ml.
  • Any concurrent illness, other than diabetes, that is not controlled by a stable therapeutic regimen.
  • Any reason the principal investigator deems exclusionary

Sites / Locations

  • Legacy Good Samaritan Hospital
  • Oregon Health and Science University

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

Artificial Pancreas Control

Arm Description

Type 1 Diabetes Mellitus subjects who fit the inclusion/exclusion criteria will undergo artificial pancreas closed-loop study for 28 hours. For the entire study, the adaptive component of Artificial Pancreas Control Software will be used to control the subject's blood glucose.

Outcomes

Primary Outcome Measures

Mean Percent of Time in Target Blood Glucose Range
Mean percent of time venous blood glucose was sampled between 70-180 mg/dl

Secondary Outcome Measures

Mean Deviation From Target Blood Glucose
Mean difference of venous blood glucose from glucose target. Daytime venous blood glucose values (7am-11pm) subtracted from daytime target of 115 mg/dl. Nighttime venous blood glucose values (11pm-7am) subtracted from nighttime target of 140 mg/dl. This is a metric of how successful the closed loop algorithm was at controlling glucose.

Full Information

First Posted
February 22, 2012
Last Updated
April 27, 2016
Sponsor
Legacy Health System
Collaborators
Juvenile Diabetes Research Foundation
search

1. Study Identification

Unique Protocol Identification Number
NCT01552603
Brief Title
Artificial Pancreas Control System in an Inpatient Setting
Official Title
Sensor-controlled Insulin- and Glucagon Delivery in Subjects With Type 1 Diabetes: Testing of an Automated System in a Supervised Inpatient Setting
Study Type
Interventional

2. Study Status

Record Verification Date
April 2016
Overall Recruitment Status
Completed
Study Start Date
March 2012 (undefined)
Primary Completion Date
August 2013 (Actual)
Study Completion Date
September 2013 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Legacy Health System
Collaborators
Juvenile Diabetes Research Foundation

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
The purpose of this study is to verify an automated system of blood glucose control in Type I Diabetics. The automated system consists of the investigational Artificial Pancreas Control software (APC), two blood glucose sensors, and two hormone pumps, one for delivering insulin to lower blood sugar, and the second for delivering glucagon to raise blood sugar. The blood glucose sensors relays information to the Artificial Pancreas software, which uses the Adaptive Proportional Device algorithm to determine the rate of insulin and glucagon infusion by the hormone pumps. In prior studies, the Adaptive Proportional Device algorithm has been verified, but required manual input into the computer and hormone pumps. This study differs in that it uses a fully automated system under the control of the Artificial Pancreas Control software. The importance of this change is that it is the next step to enable outpatient use of automated, closed loop blood glucose control.
Detailed Description
The objective of the current human study is to verify the components of the Artificial Pancreas Control system during an inpatient study. This master controller software is designed to be used in conjunction with two subcutaneous continuous glucose monitoring systems to regulate blood glucose levels as well as two Omnipod pumps, one for administering insulin and one for administering glucagon. The sensors communicate wirelessly with two sensor receivers which will be interfaced with the APC by wireless USB connection. The insulin and glucagon pumps will be controlled by the APC through a wireless USB connection. The algorithm included in the APC is an automated version of the Adaptive Proportional Derivative (APD) insulin and glucagon control algorithm, which was previously studied as an investigational device. The APD has been studied in vivo (in 28 experiments, each 33 hr in length, with manual adjustment of pumps) and no serious adverse effects were noted. Manual input of the glucose sensor data and insulin/glucagon infusion rates will no longer be necessary. The APC will be tested in vivo during 28 hour experiments in an inpatient setting in preparation for outpatient testing.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Type I Diabetes Mellitus
Keywords
glucose sensors, artificial pancreas, Diabetes Mellitus

7. Study Design

Primary Purpose
Treatment
Study Phase
Phase 2
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
14 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Artificial Pancreas Control
Arm Type
Experimental
Arm Description
Type 1 Diabetes Mellitus subjects who fit the inclusion/exclusion criteria will undergo artificial pancreas closed-loop study for 28 hours. For the entire study, the adaptive component of Artificial Pancreas Control Software will be used to control the subject's blood glucose.
Intervention Type
Device
Intervention Name(s)
Artificial Pancreas Control Software
Intervention Description
This master controller software is used in conjunction with two subcutaneous continuous glucose monitoring systems and two Omnipod pumps, one for administering aspart insulin (NovoLog) and one for administering glucagon (GlucaGen), to control blood glucose levels. The insulin and glucagon infusion rates are determined by an automated version of the Adaptive Proportional Derivative (APD) insulin and glucagon control algorithm.
Primary Outcome Measure Information:
Title
Mean Percent of Time in Target Blood Glucose Range
Description
Mean percent of time venous blood glucose was sampled between 70-180 mg/dl
Time Frame
all 28 hour studies
Secondary Outcome Measure Information:
Title
Mean Deviation From Target Blood Glucose
Description
Mean difference of venous blood glucose from glucose target. Daytime venous blood glucose values (7am-11pm) subtracted from daytime target of 115 mg/dl. Nighttime venous blood glucose values (11pm-7am) subtracted from nighttime target of 140 mg/dl. This is a metric of how successful the closed loop algorithm was at controlling glucose.
Time Frame
all 28 hour studies

10. Eligibility

Sex
All
Minimum Age & Unit of Time
21 Years
Maximum Age & Unit of Time
65 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Diagnosis of type 1 diabetes mellitus for at least 1 year. Male or female subjects 21 to 65 years of age. Current use of an insulin pump. Willingness to follow all study procedures, including attending all clinic visits. Willingness to sign informed consent and HIPAA documents. Exclusion Criteria: Pregnancy or Lactation: For women of childbearing potential: there is a requirement for a negative urine pregnancy test and for agreement to use contraception during the study and for at least 1 month after participating in the study. Acceptable contraception includes birth control pill / patch / vaginal ring, Depo-Provera, Norplant, an IUD, the double barrier method (the woman uses a diaphragm and spermicide and the man uses a condom), or abstinence. Renal insufficiency (serum creatinine of 2.0 mg/dL or greater). Serum ALT or AST equal to or greater than 3 times the upper limit of normal; hepatic synthetic insufficiency as defined as a serum albumin of less than 3.3 g/dL; or serum bilirubin of over 2. Adrenal insufficiency Hematocrit of less than or equal to 34%. A history of cerebrovascular disease or coronary artery disease regardless of the time since occurrence. Congestive heart failure, NYHA class III or IV. Diagnosis of 2nd or 3rd degree heart block or any arrhythmia judged by the investigator to be exclusionary. Any active infection. Visual impairment preventing reading of glucose meter values or continuous glucose monitoring device. Physical impairment impeding the ability to use a glucose meter or glucose monitoring device. Active foot ulceration. Severe peripheral arterial disease characterized by ischemic rest pain or severe claudication. Active alcohol abuse, substance abuse, or severe mental illness (as judged by the principal investigator). Active malignancy, except basal cell or squamous cell skin cancers. Major surgical operation within 30 days prior to screening. Seizure disorder. Chronic usage of any immunosuppressive medication (such as cyclosporine, azathioprine, sirolimus, or tacrolimus). Current administration of oral or parenteral corticosteroids. Use of an investigational drug within 30 days prior to screening. Bleeding disorder, treatment with warfarin, or platelet count below 50,000. Allergy to aspart insulin. Allergy to glucagon. Past history of pheochromocytoma or a family history of MEN 2, neurofibromatosis, or von Hippel-Lindau disease. Insulin resistance requiring more than 200 units per day. Need for uninterrupted treatment of acetaminophen. Intolerance of mild hypoglycemia (glucose 60-70 mg/dl). History of hypoglycemic unawareness. Insulin antibody level of ≥ 100 µUnits/ml. C peptide level of ≥0.5 ng/ml. Any concurrent illness, other than diabetes, that is not controlled by a stable therapeutic regimen. Any reason the principal investigator deems exclusionary
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
W K Ward, MD
Organizational Affiliation
Legacy Health Research
Official's Role
Principal Investigator
Facility Information:
Facility Name
Legacy Good Samaritan Hospital
City
Portland
State/Province
Oregon
ZIP/Postal Code
97210
Country
United States
Facility Name
Oregon Health and Science University
City
Portland
State/Province
Oregon
ZIP/Postal Code
97239
Country
United States

12. IPD Sharing Statement

Citations:
PubMed Identifier
22226248
Citation
El Youssef J, Castle JR, Branigan DL, Massoud RG, Breen ME, Jacobs PG, Bequette BW, Ward WK. A controlled study of the effectiveness of an adaptive closed-loop algorithm to minimize corticosteroid-induced stress hyperglycemia in type 1 diabetes. J Diabetes Sci Technol. 2011 Nov 1;5(6):1312-26. doi: 10.1177/193229681100500602.
Results Reference
background

Learn more about this trial

Artificial Pancreas Control System in an Inpatient Setting

We'll reach out to this number within 24 hrs