Assessment of Novel Sound Changing Principles in Hearing Instruments to Determine Their Application - 2018_12
Primary Purpose
Hearing Loss
Status
Completed
Phase
Not Applicable
Locations
Switzerland
Study Type
Interventional
Intervention
Hearing Aid without NR
Hearing Aid with NR_A
Hearing Aid with NR_B
Hearing Aid with NR_C
Sponsored by
About this trial
This is an interventional treatment trial for Hearing Loss
Eligibility Criteria
Inclusion Criteria:
- Healthy outer ear (without previous surgical procedures)
- Ability to fill in a questionnaire conscientiously
- Informed Consent as documented by signature
Exclusion Criteria:
- Contraindications to the MD in this study, e.g. known hypersensitivity or allergy to the investigational product
- Limited mobility and not in the position to attend weekly appointments
- Limited ability to describe listening impressions/experiences and the use of the hearing aid
- Inability to produce a reliable hearing test result
- Massively limited dexterity
- Known psychological problems
- Known central hearing disorders
- colour blinded
Sites / Locations
- Sonova AG
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm 4
Arm Type
Active Comparator
Experimental
Experimental
Experimental
Arm Label
Hearing Aid without NR
Hearing Aid with NR_A
Hearing Aid with NR_B
Hearing Aid with NR_C
Arm Description
Hearing Aid without Noise Reduction (NR) serves as reference condition.
NR_A: Noise Reduction principle A
NR_B: Noise Reduction principle B.
NR_C: Noise Reduction principle C.
Outcomes
Primary Outcome Measures
Sound quality ratings
The sound quality ratings will be assessed with the aid of a Multi-Stimulus Test. The data, serving as the primary outcome measure, are collected in the laboratory and will use a continuous rating scale. The scale ranges from 0 "very bad" to 100 "very good" in increments of 1.
Secondary Outcome Measures
Oldenburg sentence test in noise
The data, serving as secondary outcome is a Signal to noise ratio (SNR) in decibel (dB) where a 50% speech reception threshold is reached. This outcome measurement will be carried out in the laboratory.
Oldenburg sentence test & manual tracking task
A dual task paradigm will be used in which the Oldenburg Sentence test in noise will be administered as a primary task, and the subject will manually track a point on a computerised elliptical track as a secondary task. The aim is to recall as many words from the presented sentence at a predefined SNR and track the point as accurately as possible at the same time. The SNR is set as the level at which a subject reaches a speech reception threshold of 80-90%. The data derived, serving as a secondary outcome measure, are a [%] of time on target and distance error from the target.
Adaptive Categorial Listening Effort Scaling (ACALES)
The ACALES procedure determines self-reported individual listening effort on a scale from "extreme effort" to "no effort" within a signal-to-noise ratio range that corresponds to individual subject perceptions.
The data, serving as a secondary outcome, are a set of points on a categorial scale (subjectively perceived listening effort) as a function of different SNRs.
Self-report form
A qualitative questionnaire with predefined questions and comment sections to gather information on individual perceptions regarding the comparison of two different hearing programs during different laboratory-based acoustic scenes. For details of the hearing aid settings, see study arms. The data collected from this questionnaire are scores on a continuous rating scale ranging from "hearing program A is much worse than hearing program B" to "hearing program B is much better than hearing program A" and any subjective comments given.
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT03554577
Brief Title
Assessment of Novel Sound Changing Principles in Hearing Instruments to Determine Their Application - 2018_12
Official Title
Assessment of Novel Sound Changing Principles in Hearing Instruments to Determine Their Application
Study Type
Interventional
2. Study Status
Record Verification Date
November 2018
Overall Recruitment Status
Completed
Study Start Date
May 28, 2018 (Actual)
Primary Completion Date
August 31, 2018 (Actual)
Study Completion Date
October 2, 2018 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Sonova AG
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No
5. Study Description
Brief Summary
A methodical evaluation of novel sound changing principles in CE-labelled Sonova brand hearing instruments (e.g. Phonak hearing instruments) is intended to be conducted on hearing impaired participants. These sound changing principles are enabled by respective hearing instrument technologies and hearing instrument algorithms. The aim of the study is to investigate and asses strength and weaknesses of these novel sound changing principles in terms of hearing performance to determine their application in hearing instruments (Phase of development). Both, objective laboratory measurements as well as subjective evaluations in real life environment will be carried out. This will be a controlled, single blinded and randomised active comparator clinical evaluation which will be conducted mono centric at Sonova AG Headquarter based in Stäfa
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Hearing Loss
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Model Description
Each participant will be treated with each sound changing principle (Noise Reduction principle (NR)) in a randomized order.
Masking
Participant
Allocation
Randomized
Enrollment
15 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Hearing Aid without NR
Arm Type
Active Comparator
Arm Description
Hearing Aid without Noise Reduction (NR) serves as reference condition.
Arm Title
Hearing Aid with NR_A
Arm Type
Experimental
Arm Description
NR_A: Noise Reduction principle A
Arm Title
Hearing Aid with NR_B
Arm Type
Experimental
Arm Description
NR_B: Noise Reduction principle B.
Arm Title
Hearing Aid with NR_C
Arm Type
Experimental
Arm Description
NR_C: Noise Reduction principle C.
Intervention Type
Device
Intervention Name(s)
Hearing Aid without NR
Other Intervention Name(s)
NR: Noise Reduction
Intervention Description
Each participant will be fitted with the 4 different Noise Reduction (Sound Changing) principles on the same hearing aid, saved to 4 manual programs.
Noise Reduction principle is a sound processing algorithm to remove noise from a speech signal to improve the speech intelligibility and comfort. The experimental conditions vary in their parametrization to result in different degrees of noise suppression and good speech quality.
Intervention Type
Device
Intervention Name(s)
Hearing Aid with NR_A
Other Intervention Name(s)
NR_A: Noise Reduction principle A
Intervention Description
Each participant will be fitted with the 4 different Noise Reduction (Sound Changing) principles on the same hearing aid, saved to 4 manual programs.
Noise Reduction principle is a sound processing algorithm to remove noise from a speech signal to improve the speech intelligibility and comfort. The experimental conditions vary in their parametrization to result in different degrees of noise suppression and good speech quality.
Intervention Type
Device
Intervention Name(s)
Hearing Aid with NR_B
Other Intervention Name(s)
NR_B: Noise Reduction principle B
Intervention Description
Each participant will be fitted with the 4 different Noise Reduction (Sound Changing) principles on the same hearing aid, saved to 4 manual programs.
Noise Reduction principle is a sound processing algorithm to remove noise from a speech signal to improve the speech intelligibility and comfort. The experimental conditions vary in their parametrization to result in different degrees of noise suppression and good speech quality.
Intervention Type
Device
Intervention Name(s)
Hearing Aid with NR_C
Other Intervention Name(s)
NR_C: Noise Reduction principle C
Intervention Description
Each participant will be fitted with the 4 different Noise Reduction (Sound Changing) principles on the same hearing aid, saved to 4 manual programs.
Noise Reduction principle is a sound processing algorithm to remove noise from a speech signal to improve the speech intelligibility and comfort. The experimental conditions vary in their parametrization to result in different degrees of noise suppression and good speech quality.
Primary Outcome Measure Information:
Title
Sound quality ratings
Description
The sound quality ratings will be assessed with the aid of a Multi-Stimulus Test. The data, serving as the primary outcome measure, are collected in the laboratory and will use a continuous rating scale. The scale ranges from 0 "very bad" to 100 "very good" in increments of 1.
Time Frame
4 weeks
Secondary Outcome Measure Information:
Title
Oldenburg sentence test in noise
Description
The data, serving as secondary outcome is a Signal to noise ratio (SNR) in decibel (dB) where a 50% speech reception threshold is reached. This outcome measurement will be carried out in the laboratory.
Time Frame
4 weeks
Title
Oldenburg sentence test & manual tracking task
Description
A dual task paradigm will be used in which the Oldenburg Sentence test in noise will be administered as a primary task, and the subject will manually track a point on a computerised elliptical track as a secondary task. The aim is to recall as many words from the presented sentence at a predefined SNR and track the point as accurately as possible at the same time. The SNR is set as the level at which a subject reaches a speech reception threshold of 80-90%. The data derived, serving as a secondary outcome measure, are a [%] of time on target and distance error from the target.
Time Frame
4 weeks
Title
Adaptive Categorial Listening Effort Scaling (ACALES)
Description
The ACALES procedure determines self-reported individual listening effort on a scale from "extreme effort" to "no effort" within a signal-to-noise ratio range that corresponds to individual subject perceptions.
The data, serving as a secondary outcome, are a set of points on a categorial scale (subjectively perceived listening effort) as a function of different SNRs.
Time Frame
2 weeks
Title
Self-report form
Description
A qualitative questionnaire with predefined questions and comment sections to gather information on individual perceptions regarding the comparison of two different hearing programs during different laboratory-based acoustic scenes. For details of the hearing aid settings, see study arms. The data collected from this questionnaire are scores on a continuous rating scale ranging from "hearing program A is much worse than hearing program B" to "hearing program B is much better than hearing program A" and any subjective comments given.
Time Frame
One week
Other Pre-specified Outcome Measures:
Title
Interaural Phase Difference (IPD) Detection thresholds
Description
A 2 Interval - 2 Alternative Forced Choice task to measure the psychometric function of IPD detection with changing stimulus frequency. The data, serving as an outcome measure, is the individual interaural phase difference (IPD) frequency threshold (the frequency up to which 75% correct answers are given).
Time Frame
1 week
Title
Non-verbal Trail Making Test A & B
Description
The Trail Making Test is a neuropsychological test of visual attention and task switching. It consists of two parts in which the subject is instructed to connect a set of 25 dots as quickly as possible while still maintaining accuracy. The data, serving as an outcome measure, are time-to-complete the set in seconds.
Time Frame
1 week
Title
color-word-interference test by J.R.Stroop
Description
The color-word- interference test ("Farb-Wort-Interferenztest nach J.R.Stroop" (version: "Günther Bäumler")) is a neuropsychological test of visual attention and interferer suppression and will be carried out in the laboratory. In the first trial, the subject has to read the names of colours written on a card as fast and accurately as possible. In the second trial, the subject has to name the colour ink of filled boxes on a card as quickly and accurately as possible. In the third trial, the names of colours are written on a card in a dissimilarly coloured ink. The participant must read aloud the written words, whilst ignoring the colour of the ink. The data, serving as an outcome measure, are time-to-complete the sets in seconds.
Time Frame
1 week
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
99 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Healthy outer ear (without previous surgical procedures)
Ability to fill in a questionnaire conscientiously
Informed Consent as documented by signature
Exclusion Criteria:
Contraindications to the MD in this study, e.g. known hypersensitivity or allergy to the investigational product
Limited mobility and not in the position to attend weekly appointments
Limited ability to describe listening impressions/experiences and the use of the hearing aid
Inability to produce a reliable hearing test result
Massively limited dexterity
Known psychological problems
Known central hearing disorders
colour blinded
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Juliane Raether
Organizational Affiliation
Sonova AG
Official's Role
Principal Investigator
Facility Information:
Facility Name
Sonova AG
City
Stäfa
ZIP/Postal Code
8712
Country
Switzerland
12. IPD Sharing Statement
Plan to Share IPD
No
Learn more about this trial