About this trial

This is an interventional treatment trial for Mitral Valve Disease focused on measuring Mitral valve disease, primarily regurgitation, necessitating surgical repair

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • All patients requiring the use of an mitral anuloplasty device to restore the mitral competence by surgery are potential candidates for study inclusion, if survival of at least more than 1 year is expected

Sites / Locations

  • Ghent University Hospital

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

MEMO 3D anuloplasty ring

rigid ring

Arm Description

MEMO 3D anuloplasty ring

rigid ring

Outcomes

Primary Outcome Measures

Difference of diameters and surface of the anuloplasty device between systolic and diastolic phase of the cardiac cycle in the MEMO 3D device, compared to another rigid ring device.
Difference of antero-posterior diameter, latero-lateral diameter and surface of the anuloplasty device between systolic and diastolic phase of the cardiac cycle in the MEMO 3D device, compared to another rigid ring device. The measurements are done with the use of 3-D echocardiography
Difference of diameters and surface of the anuloplasty device between systolic and diastolic phase of the cardiac cycle in the MEMO 3D device, compared to another rigid ring device.
Difference of antero-posterior diameter, latero-lateral diameter and surface of the anuloplasty device between systolic and diastolic phase of the cardiac cycle in the MEMO 3D device, compared to another rigid ring device. The measurements are done with the use of 3-D echocardiography

Secondary Outcome Measures

Full Information

First Posted
November 12, 2013
Last Updated
December 6, 2022
Sponsor
University Hospital, Ghent
Collaborators
LivaNova
search

1. Study Identification

Unique Protocol Identification Number
NCT01987635
Brief Title
Assessment of Sustained Systolic-to-diastolic Flexibility of the Mitral Valve Annulus With the Sorin MEMO 3D Mitral Anuloplasty Ring
Acronym
MEMO 3D
Official Title
Assessment of Sustained Systolic-to-diastolic Flexibility of the Mitral Valve Annulus With the Sorin MEMO 3D Mitral Anuloplasty Ring
Study Type
Interventional

2. Study Status

Record Verification Date
December 2022
Overall Recruitment Status
Completed
Study Start Date
January 16, 2014 (Actual)
Primary Completion Date
September 13, 2016 (Actual)
Study Completion Date
September 28, 2018 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University Hospital, Ghent
Collaborators
LivaNova

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
Mitral valve reconstruction commonly requires the use of an anuloplasty device to assure long-term durability of the repair. Among mitral anuloplasty devices, varying from rigid to complete flexible ring substitutes, the most recent ones are aimed to restore the natural saddle shape of the mitral annulus, in order to decrease the stress tension on both mitral leaflets and chordal attachments. So far, even for flexible ring devices, the sustained flexibility of the device remained unproven, probably by cicatricial fibrotic tissue ingrowth after implantation. Due to specific structural characteristics based on a nitinolstent with carbofilm-coating, the MEMO 3D ring device of SORIN claims preservation of the ring flexibility during the cardiac cyclus. Consequently, mitral anuloplasty with this device is expected to decrease the stress during the systolo-diastolic movements of the valve, and so, improve the late durability of the repair. Echocardiography is the first-line technique for mitral valve assessment after surgical repair, for both intra-operative evaluation and serial follow-up of valve function. Recently, three-dimensional echocardiography has been introduced into clinical practice, affording qualitative and quantitative measurement of mitral valve function and size during the cardiac cycle.This method allows to quantify precisely the excursion of the mitral annulus between systole and diastole. The aim of this study is to analyse the systolo-diastolic movement of the mitral annulus after the use of an anuloplasty with the SORIN MEMO 3D device, after surgical implantation and its sustainability, 1 year after implantation. This hypothesis is tested in a case-controlled comparison with a standard used rigid ring device. Therefore, 3-D echocardiography will be performed at the time of surgical repair, and after 1 year, to define the size and surface change of the mitral anuloplasty device during the cardiac cycle. Based on a sample size calculation, 10 patients in each comparison group will be included, suggesting a study cohort of 20 patients eligible for mitral valve repair.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Mitral Valve Disease
Keywords
Mitral valve disease, primarily regurgitation, necessitating surgical repair

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
None (Open Label)
Allocation
Non-Randomized
Enrollment
33 (Actual)

8. Arms, Groups, and Interventions

Arm Title
MEMO 3D anuloplasty ring
Arm Type
Experimental
Arm Description
MEMO 3D anuloplasty ring
Arm Title
rigid ring
Arm Type
Active Comparator
Arm Description
rigid ring
Intervention Type
Device
Intervention Name(s)
MEMO 3D ring
Intervention Description
The experimental MEMO 3D ring is placed.
Intervention Type
Device
Intervention Name(s)
Standard use of rigid ring.
Intervention Description
The rigid ring is placed, which is standard procedure.
Intervention Type
Procedure
Intervention Name(s)
3D Echocardiography
Primary Outcome Measure Information:
Title
Difference of diameters and surface of the anuloplasty device between systolic and diastolic phase of the cardiac cycle in the MEMO 3D device, compared to another rigid ring device.
Description
Difference of antero-posterior diameter, latero-lateral diameter and surface of the anuloplasty device between systolic and diastolic phase of the cardiac cycle in the MEMO 3D device, compared to another rigid ring device. The measurements are done with the use of 3-D echocardiography
Time Frame
intra-operatively
Title
Difference of diameters and surface of the anuloplasty device between systolic and diastolic phase of the cardiac cycle in the MEMO 3D device, compared to another rigid ring device.
Description
Difference of antero-posterior diameter, latero-lateral diameter and surface of the anuloplasty device between systolic and diastolic phase of the cardiac cycle in the MEMO 3D device, compared to another rigid ring device. The measurements are done with the use of 3-D echocardiography
Time Frame
1 year after implantation.

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: All patients requiring the use of an mitral anuloplasty device to restore the mitral competence by surgery are potential candidates for study inclusion, if survival of at least more than 1 year is expected
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Guy Vandenplas, MD
Organizational Affiliation
University Hospital, Ghent
Official's Role
Principal Investigator
Facility Information:
Facility Name
Ghent University Hospital
City
Ghent
ZIP/Postal Code
9000
Country
Belgium

12. IPD Sharing Statement

Links:
URL
http://www.uzgent.be
Description
Related Info

Learn more about this trial

Assessment of Sustained Systolic-to-diastolic Flexibility of the Mitral Valve Annulus With the Sorin MEMO 3D Mitral Anuloplasty Ring

We'll reach out to this number within 24 hrs