Boston Scientific COMET Wire Validation Study (COMET)
Primary Purpose
Stable Angina
Status
Completed
Phase
Not Applicable
Locations
United Kingdom
Study Type
Interventional
Intervention
Boston Scientific Pressure Wire
Validation of Boston Scientific pressure wire
Sponsored by
About this trial
This is an interventional diagnostic trial for Stable Angina focused on measuring pressure wire, coronary angiogram, validation
Eligibility Criteria
Inclusion Criteria
- >18yrs age
- Written informed consent
- Patients scheduled for diagnostic angiography (and/or "standby" angiography)
- Clinical requirement for pressure wire assessment
Exclusion Criteria
- STEMI presentation
- Aorto-ostial disease
- Pregnancy
- CABG
- Contraindication to adenosine
- Creatinine >180umol/L
- Life threatening co-morbidity
- Severe valve disease
Sites / Locations
- Liverpool Heart & Chest NHS Foundation Trust
- Southampton General Hospital
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm Type
Experimental
Experimental
Active Comparator
Arm Label
Boston Scientific PW versus St Jude PW
Boston Sci PW vs Boston Sci PW
St Jude PW versus St Jude PW
Arm Description
Performance of Boston Scientific PW vs St Jude PW
Boston Sci PW vs Boston Sci PW
Performance of St Jude PW vs St Jude PW
Outcomes
Primary Outcome Measures
Coronary artery pressure as measured by Boston Scientific Pressure Wire (BSPW)
The study will involve the use of two pressure wires simultaneously in a coronary artery.
The three randomisation groups will allow the comparison of pressure measurements between two different wires (BSPW vs SJPW) and will document consistency of readings within the same wire (BSPW vs BSPW or SJPW vs SJPW). Measurements will be undertaken using standard drug protocols. No additional drugs will be necessary for study purposes.
The first wire allocated at randomisation will be passed to the target measurement position in the artery
The second wire allocated at randomisation will be passed to exactly the same point in the vessel
Positioning of the wires will be confirmed by X-rays
Simultaneous measurements will be taken from the 2 pressure wires
If there is a narrowing in more than one vessel the process will be repeated for each vessel. Once the measurement has been taken, both wires will be removed.
Coronary artery pressure as measured by St Jude Medical Pressure Wire (SJPW)
The study will involve the use of two pressure wires simultaneously in a coronary artery.
The three randomisation groups will allow the comparison of pressure measurements between two different wires (BSPW vs SJPW) and will document consistency of readings within the same wire (BSPW vs BSPW or SJPW vs SJPW). Measurements will be undertaken using standard drug protocols. No additional drugs will be necessary for study purposes.
The first wire allocated at randomisation will be passed to the target measurement position in the artery
The second wire allocated at randomisation will be passed to exactly the same point in the vessel
Positioning of the wires will be confirmed by X-rays
Simultaneous measurements will be taken from the 2 pressure wires
If there is a narrowing in more than one vessel the process will be repeated for each vessel. Once the measurement has been taken, both wires will be removed.
Secondary Outcome Measures
Full Information
NCT ID
NCT02578381
First Posted
September 29, 2015
Last Updated
May 16, 2017
Sponsor
University Hospital Southampton NHS Foundation Trust
Collaborators
Liverpool Heart and Chest Hospital NHS Foundation Trust, Boston Scientific Corporation
1. Study Identification
Unique Protocol Identification Number
NCT02578381
Brief Title
Boston Scientific COMET Wire Validation Study
Acronym
COMET
Official Title
Boston Scientific COMET Wire Validation Study
Study Type
Interventional
2. Study Status
Record Verification Date
May 2017
Overall Recruitment Status
Completed
Study Start Date
March 16, 2016 (Actual)
Primary Completion Date
November 14, 2016 (Actual)
Study Completion Date
November 14, 2016 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University Hospital Southampton NHS Foundation Trust
Collaborators
Liverpool Heart and Chest Hospital NHS Foundation Trust, Boston Scientific Corporation
4. Oversight
Data Monitoring Committee
No
5. Study Description
Brief Summary
Summary of Study Aims
To assess, in a randomised fashion:
performance of Boston Scientific Pressure Wire versus St Jude Pressure Wire
performance of Boston Scientific Pressure Wire versus Boston Scientific Pressure Wire
performance of St Jude Pressure Wire versus St Jude Pressure Wire
Detailed Description
Given the following key points of evidence, the optimal management of chest pain patients who come to diagnostic coronary angiography would more often be achieved if there was concomitant data with regard to the presence of patient-specific and lesion-specific ischaemia:
that it is the presence and extent of reversible myocardial ischaemia (RMI) that dominates over coronary anatomy as a predictor of near term cardiovascular events, as well as symptom relief
that prognostic benefit after revascularisation is greatest in patients with the largest pre-procedure ischaemic burden
that intra-coronary pressure wire (PW) data are strongly correlated with subsequent cardiac events despite the binary nature of the test
that stenting of coronary lesions that are PW negative has a worse outcome than optimal medical therapy (OMT)
that PW-directed percutaneous coronary intervention (PCI) in multivessel disease is associated with a better clinical outcome than angiogram-directed PCI despite fewer treated lesions and less stents
that PW-directed PCI improves prognosis compared to OMT
that mismatch exists in up to 30-40% of lesions encountered at angiography between the visual appearance of the severity of the lesion and whether the lesion is "ischaemic" (and therefore a target for revascularisation) according to PW.
The availability of PW has been shown to have had a substantial effect on overall management of patients undergoing diagnostic coronary angiography (ie when options are still OMT/PCI and coronary artery bypass grafting (CABG) in several observation studies including RIPCORD and the French Registry.
Yet, despite the seemingly persuasive data summarised here, the uptake of PW at the diagnostic stage of the patient pathway is still low. There are, as yet, no suitably powered randomised trials using the PW systematically at the stage of diagnostic angiography and comparing outcome with management based upon angiography alone. This is the gap that will be filled by RIPCORD2.
RIPCORD2 will use the new Boston Scientific Pressure Wire (BSPW), which is currently undergoing first-in-man testing in Chile. The device has, of course, already been internally validated by Boston Scientific engineers and scientists, but the purpose of the COMET study is to provide independent and objective validation of the performance of BSPW using the performance of the St Jude Medical pressure wire (SJPW) as the reference, both using inter-wire and intra-wire measurements. Thus, not only will we assess the reproducibility of the measurements between the 2 wires, but the investigators will also compare reproducibility of measurements from 2 wires of the same manufacturer.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Stable Angina
Keywords
pressure wire, coronary angiogram, validation
7. Study Design
Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Factorial Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
106 (Actual)
8. Arms, Groups, and Interventions
Arm Title
Boston Scientific PW versus St Jude PW
Arm Type
Experimental
Arm Description
Performance of Boston Scientific PW vs St Jude PW
Arm Title
Boston Sci PW vs Boston Sci PW
Arm Type
Experimental
Arm Description
Boston Sci PW vs Boston Sci PW
Arm Title
St Jude PW versus St Jude PW
Arm Type
Active Comparator
Arm Description
Performance of St Jude PW vs St Jude PW
Intervention Type
Device
Intervention Name(s)
Boston Scientific Pressure Wire
Intervention Description
St Jude Medical Pressure Wire
Intervention Type
Device
Intervention Name(s)
Validation of Boston Scientific pressure wire
Primary Outcome Measure Information:
Title
Coronary artery pressure as measured by Boston Scientific Pressure Wire (BSPW)
Description
The study will involve the use of two pressure wires simultaneously in a coronary artery.
The three randomisation groups will allow the comparison of pressure measurements between two different wires (BSPW vs SJPW) and will document consistency of readings within the same wire (BSPW vs BSPW or SJPW vs SJPW). Measurements will be undertaken using standard drug protocols. No additional drugs will be necessary for study purposes.
The first wire allocated at randomisation will be passed to the target measurement position in the artery
The second wire allocated at randomisation will be passed to exactly the same point in the vessel
Positioning of the wires will be confirmed by X-rays
Simultaneous measurements will be taken from the 2 pressure wires
If there is a narrowing in more than one vessel the process will be repeated for each vessel. Once the measurement has been taken, both wires will be removed.
Time Frame
Day one
Title
Coronary artery pressure as measured by St Jude Medical Pressure Wire (SJPW)
Description
The study will involve the use of two pressure wires simultaneously in a coronary artery.
The three randomisation groups will allow the comparison of pressure measurements between two different wires (BSPW vs SJPW) and will document consistency of readings within the same wire (BSPW vs BSPW or SJPW vs SJPW). Measurements will be undertaken using standard drug protocols. No additional drugs will be necessary for study purposes.
The first wire allocated at randomisation will be passed to the target measurement position in the artery
The second wire allocated at randomisation will be passed to exactly the same point in the vessel
Positioning of the wires will be confirmed by X-rays
Simultaneous measurements will be taken from the 2 pressure wires
If there is a narrowing in more than one vessel the process will be repeated for each vessel. Once the measurement has been taken, both wires will be removed.
Time Frame
Day one
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria
>18yrs age
Written informed consent
Patients scheduled for diagnostic angiography (and/or "standby" angiography)
Clinical requirement for pressure wire assessment
Exclusion Criteria
STEMI presentation
Aorto-ostial disease
Pregnancy
CABG
Contraindication to adenosine
Creatinine >180umol/L
Life threatening co-morbidity
Severe valve disease
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Nick Curzen, BM(Hons) PhD
Organizational Affiliation
University Hospital Southampton NHS Foundation Trust
Official's Role
Principal Investigator
Facility Information:
Facility Name
Liverpool Heart & Chest NHS Foundation Trust
City
Liverpool
State/Province
Merseyside
ZIP/Postal Code
L14 3PE
Country
United Kingdom
Facility Name
Southampton General Hospital
City
Southampton
ZIP/Postal Code
SO16 6YD
Country
United Kingdom
12. IPD Sharing Statement
Plan to Share IPD
No
Learn more about this trial
Boston Scientific COMET Wire Validation Study