Brain Computer Interface for Communication in Ventilated Patients

Primary Purpose

Mechanical Ventilation, Nonverbal Communication, Intratracheal Intubation

Status
Terminated
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Brain Computer Interface (BCI) device
Communication picture board
Sponsored by
University of Michigan
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional other trial for Mechanical Ventilation focused on measuring Brain-Computer Interface, Intratracheal intubation, Mechanical ventilation, Nonverbal communication, Critical illness, Electroencephalography, Visual Evoked Potential

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Admitted to an Intensive Care Unit and on mechanical ventilation for at least 24 hours
  • Age 18 years or older
  • Able to briskly follow commands
  • Unimpaired use of at least one upper limb

Exclusion Criteria:

  • Ongoing respiratory distress, severe pain or other source of obvious discomfort requiring immediate medical or nursing attention
  • Severe hemodynamic instability with ongoing need for vasopressor titration or resuscitation
  • Known impairment of vision, other than error of refraction with corrective lenses present
  • Inability to tolerate interruption of sedation
  • Inability to communicate fluently in English
  • Need for ongoing EEG monitoring

Sites / Locations

  • University of Michigan Health System

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

Brain Computer Interface (BCI) device

Arm Description

The patient uses the Brain Computer Interface (BCI) device in the ICU for communication for 2 hours a day for 3 consecutive days. The patient then uses a communication picture board for 2 hours a day for 3 consecutive days on the same days that the BCI device is used for comparison.

Outcomes

Primary Outcome Measures

BCI device accuracy
Accurate selection of the illustrative icon on the brain computer interface representing the physical or emotional need self-identified by the patient as being the most common trigger for communication with the bedside nurse during their admission.

Secondary Outcome Measures

Satisfaction survey
Selection by patients or family of "agree" or "strongly agree" with the statement "The Brain computer interface device allowed me to communicate my needs to the bedside nurse adequately".

Full Information

First Posted
June 1, 2016
Last Updated
April 15, 2019
Sponsor
University of Michigan
Collaborators
Michigan Institute for Clinical and Health Research (MICHR)
search

1. Study Identification

Unique Protocol Identification Number
NCT02791425
Brief Title
Brain Computer Interface for Communication in Ventilated Patients
Official Title
Wearable Brain Computer Interface (BCI) to Assist Communication in Mechanically Ventilated Patients the Intensive Care Unit (ICU)
Study Type
Interventional

2. Study Status

Record Verification Date
April 2019
Overall Recruitment Status
Terminated
Why Stopped
The developer of the BCI left the institution so the study could not continue
Study Start Date
March 1, 2017 (Actual)
Primary Completion Date
August 25, 2017 (Actual)
Study Completion Date
August 25, 2017 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
University of Michigan
Collaborators
Michigan Institute for Clinical and Health Research (MICHR)

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
Objectives: Specific Aim 1: To demonstrate the feasibility of using a Steady State Visual Evoked Potential (SSVEP) based Brain Computer Interface (BCI) device to facilitate communication of common patient needs in alert mechanically ventilated patients in the Intensive Care Unit (ICU). Specific Aim 2: To determine patient, family and bedside nurse satisfaction with communication using the BCI device and elicit open-ended feedback to guide future device improvements Design: Translational pilot study of a Steady State Visual Evoked Potential (SSVEP) based BCI system to facilitate communication in intubated patients, with sequential use of the BCI device and a picture board. Selection of the primary self-identified primary patient need on the BCI device will be compared to the icon selected on the picture board (reference standard). A patient satisfaction survey will then be provided to the patient or a family member following use for 2 hours a day for 3 consecutive days. Primary outcome: Accurate selection of the illustrative icon on the brain computer interface representing the physical or emotional need self-identified by the patient as being the most common trigger for communication with the bedside nurse during their admission. Secondary outcome: Selection by patients or family of "agree" or "strongly agree" with the statement "The Brain computer interface device allowed me to communicate my needs to the bedside nurse adequately". Intervention: Use of the brain computer device in the ICU for communication for 2 hours a day for 3 consecutive days Control/ Comparator: Sequential use of a communication picture board for 2 hours a day for 3 consecutive days, on the same days that the BCI device is used Sample Size: 30 mechanically ventilated but alert patients in the Intensive Care Unit
Detailed Description
BACKGROUND An inability to consistently and effectively communicate their most fundamental physical needs is a major problem for mechanically ventilated ICU patients. Patients rate about 40% of communication sessions as difficult and more than a third of communications about pain as unsuccessful. Nurses initiate about 86% of all communication exchanges as it is typically very difficult for a voiceless ICU patient to initiate communication. Patients in the ICU therefore commonly suffer unrecognized pain and discomfort, feelings of loss of control and insecurity, depersonalization, anxiety, sleep disturbances, fear and frustration. Caregivers also frequently report feeling anxious and frustrated in not being able to adequately assess the needs of their patients. This inability to communicate effectively can lead to the inappropriate use of sedatives and prolongation of time spent on the ventilator, which may then lead to increased ICU length of stay and costs. Furthermore, the inability to communicate with caregivers hampers the ability of critically ill patients to be active participants in their treatment and in decision-making, including decisions to withdraw or withhold life-sustaining treatment. The use of picture boards with icons representing common patient needs and complaints (pain, fear, hot/ cold, thirst, bedpan etc) has been shown to improve nurse-patient communication for patients in the postoperative period on the ventilator. These picture boards are widely available in most ICUs and are the closest thing to a current standard for communication with voiceless mechanically ventilated patient, for the purposes of addressing fundamental physical and emotional needs. Recent pilot studies have described the use of computer-assisted communication using touch sensitive screens, eye blink detectors and gaze trackers to enable communication in the ICU patient. The majority of patients and hospital staff surveyed in these studies indicated that the use of a computer-assisted communication device improved the ability to respond to patient needs and address patient comfort. Gaze and eye blink tracker systems are expensive, however, while touch sensitive screens may not be suitable for the many ICU patients with weakness and restriction in motor ability. Patients in the ICU, particularly those with neurological illness, frequently suffer from significant weakness and loss of co-ordination, however, limiting their ability to use their arms and hands to indicate the appropriate item on the board. While patients in the neuroICU are frequently weak because of focal brain injury, about a quarter of patients requiring mechanical ventilation in other ICUs may have significant weakness from critical illness neuropathy and myopathy, limiting their ability to use their hands to select the appropriate icon on a picture board. There are several patient populations, however, for whom the use of a picture board or touch screen is impossible, including patients with high spinal cord injury, advanced ALS and brainstem stroke, who are voiceless, but also typically have no useful motor function of their limbs. These patients are "locked-in", to varying degrees, awake and alert but with no control of bodily function or ability to articulate and communicate using standard forms of communication. The use of Brain Computer Interface (BCI) devices to facilitate communication in "voiceless" patients has recently generated interest. A BCI translates deliberate, voluntary modulation of cerebral electrical activity, typically recorded by electroencephalography (EEG) into computer commands. A variety of BCI devices have been used to permit patients with advanced Amyotrophic Lateral Sclerosis (ALS), high spinal cord injury and brainstem stroke with the locked-in-syndrome, who have no voluntary use of their limbs, to communicate to varying degrees. These devices have typically been evaluated in the rehabilitation setting, following the period of acute medical illness, or at home. No study has evaluated the use of a BCI device to assist with communication of the typical physical and emotional needs/ complaints of the critically ill. This is significant, not only for patients with spinal cord injury and stroke, most of who are initially admitted to an ICU, but to the potentially large number of ICU patients who cannot use a picture board or other finger contact system because of critical illness neuropathy/ myopathy or acute brain injury causing weakness. Our focus is on creating a steady state visual evoked potential (SSVEP) based, wireless BCI system to facilitate communication with intubated ICU patients., The wearable BCI device of interest in this study functions through visual attention to illustrative icons displayed on an electronic screen. The icon, which may depict a common ICU patient need, such the need for repositioning or common patient complaint, such as pain, can be displayed as a symbol. The patient can, thereby, communicate by looking at a specific item depicting their need or complaint. This wearable device is entirely noninvasive and without significant risk to patients, functioning only to record and translate EEG signals. The device will communicate wirelessly with the user interface (UI) that can be either a tablet or the flat screen TV monitor that is present in every ICU patient room. The proposed prototype provides a user interface that includes basic functions that are typically used in communication between nurses and patients in the ICU. STUDY DESIGN This is a translational pilot study of a Steady State Visual Evoked Potential (SSVEP) based BCI system to facilitate communication in intubated patients. After obtaining informed consent from the patient or their legally authorized representative, 30 patients will be recruited from the medical, surgical, cardiac, cardiothoracic and neurological intensive care units at the University of Michigan, Ann Arbor over a period of 12 months. Approval has been obtained from the Institutional Review Board of the University of Michigan (HUM00095052). Screening for delirium and ability to participate in the study: Potential subjects will be identified by members of the primary ICU team, who will then contact a study investigator. Subjects will need to be off all sedating medicines with return to full wakefulness prior to further evaluation. Patients meeting the above eligibility criteria who consent to participate in the study will then undergo further testing by an investigator to confirm that the patient is sufficiently alert and attentive to communicate AND is capable of consistently selecting items through volitional finger contact. The patient will then undergo a screening evaluation with the BCI device to confirm that their individual EEG signal can be detected and interpreted by the device. Patient complaints/ needs: The investigators will evaluate the ability of subjects to accurately select a specific need or complaint from 10 common needs/ complaints. "I am in pain" "I have difficulty breathing" "I need to be suctioned" "I need to have a bowel movement" "I need to pee/ pass urine" "I am thirsty" "I am hungry" "I need to have my position in bed changed" "Raise the head of my bed" "I need my family at my bedside" Picture board: Feasibility of communication using the BCI device will be evaluated using a picture board with illustrative icons representing the 10 needs/ complaints above as the standard for comparison and to determine the accuracy of selection of the appropriate icon. The icons and phrases on the picture board will be identical to the icons and phrases on the BCI device SPECIFIC AIM 1: To demonstrate the feasibility of using a Steady State Visual Evoked Potential (SSVEP) based Brain Computer Interface (BCI) device to facilitate communication of common patient needs in alert mechanically ventilated patients in the Intensive Care Unit (ICU). Hypothesis 1: At least 80% of alert mechanically ventilated patients will be able to accurately select the illustrative icon on the brain computer interface representing the physical or emotional need self-identified by the patient as being the most common trigger for communication with the bedside nurse during their admission. Orientation to BCI and picture board: The patient will initially be familiarized with both the picture board and the BCI device. Instruction on use of the BCI device will include demonstration of the UI, explanation of the icons on the UI and the mechanism of selection of an icon, through focused visual attention. Selection of need/ complaint: Immediately following orientation, testing for accuracy of the BCI device will be performed. Testing for accuracy will be performed a single time for each patient, using the most important need/ complaint for that patient. The patient will be asked to identify on the BCI UI the specific need or complaint as being the most common reason to request the assistance of the bedside nurse during their admission, among the 10 patient need/ complaint options provided. Selection of "None of the above/ Other" will be permitted, however, the patient will be specifically instructed in advance to select the need/ complaint most applicable to their situation among the 10 choices provided. The patient will then be asked to select the SAME need/ complaint on the picture board using finger contact. SPECIFIC AIM 2: Specific Aim 2: To determine patient, family and bedside nurse satisfaction with communication using the BCI device and elicit open-ended feedback to guide future device improvements. Hypothesis 2: At least 70% of patients will "agree" or "strongly agree" with the statement "The Brain computer interface device allowed me to communicate my needs to the bedside nurse adequately". Immediately following evaluation of accuracy described under Specific Aim 1, the investigators will evaluate patient, family and bedside nurse satisfaction following bedside use of the device as the primary communication tool for 2 hours a day for 3 consecutive days. A delirium screen using CAM-ICU and a brief neurological examination to confirm the patient's ability to effectively use the BCI device and picture board will be performed prior to use of the device or picture board on subsequent days (days 2 and 3). At the end of the 3 days, the patient, any family members present and each nurse who participated in testing will be provided the short questionnaires. The patient questionnaire with options will be read out to the patient. Statistical Analysis: The proportion of patients who pass Step 2 of screening who then also pass Step 3 will be calculated with exact binomial 95% confidence intervals. A proportion of at least 70% passing Step 3 of screening will be the initial threshold for feasibility, based on clinical estimates of value. The median time, with interquartile range, required for orientation to the BCI device and to the picture board will be calculated, and comparison performed using the Mann Whitney U-test. The proportion of patients who select the same icon on the BCI UI and the picture board will be calculated, with exact binomial 95% confidence intervals. In determining the accuracy of using the BCI device, a binomial analysis including multiple studies of BCI estimated the chance level at 63% (α = 0.05, 60 trials). Based also on a clinical estimate of what would be a minimum useful level of accuracy for a communication device, the threshold for accuracy in our study will be at least 80% of patients demonstrating concordance between selection of their most important need/ complaint on the BCI device and the picture board. Descriptive statistics will be used to for proportions of patients selecting responses to each of the satisfaction questions.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Mechanical Ventilation, Nonverbal Communication, Intratracheal Intubation, Critical Illness
Keywords
Brain-Computer Interface, Intratracheal intubation, Mechanical ventilation, Nonverbal communication, Critical illness, Electroencephalography, Visual Evoked Potential

7. Study Design

Primary Purpose
Other
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
1 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Brain Computer Interface (BCI) device
Arm Type
Experimental
Arm Description
The patient uses the Brain Computer Interface (BCI) device in the ICU for communication for 2 hours a day for 3 consecutive days. The patient then uses a communication picture board for 2 hours a day for 3 consecutive days on the same days that the BCI device is used for comparison.
Intervention Type
Device
Intervention Name(s)
Brain Computer Interface (BCI) device
Intervention Description
A BCI system to facilitate communication in intubated patients. Patients use the device in the ICU for communication for 2 hours a day for 3 consecutive days.
Intervention Type
Other
Intervention Name(s)
Communication picture board
Intervention Description
The patient then uses a communication picture board for 2 hours a day for 3 consecutive days on the same days that the BCI device is used for comparison.
Primary Outcome Measure Information:
Title
BCI device accuracy
Description
Accurate selection of the illustrative icon on the brain computer interface representing the physical or emotional need self-identified by the patient as being the most common trigger for communication with the bedside nurse during their admission.
Time Frame
Immediately following enrollment
Secondary Outcome Measure Information:
Title
Satisfaction survey
Description
Selection by patients or family of "agree" or "strongly agree" with the statement "The Brain computer interface device allowed me to communicate my needs to the bedside nurse adequately".
Time Frame
At the end of 3 days of using BCI device

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Admitted to an Intensive Care Unit and on mechanical ventilation for at least 24 hours Age 18 years or older Able to briskly follow commands Unimpaired use of at least one upper limb Exclusion Criteria: Ongoing respiratory distress, severe pain or other source of obvious discomfort requiring immediate medical or nursing attention Severe hemodynamic instability with ongoing need for vasopressor titration or resuscitation Known impairment of vision, other than error of refraction with corrective lenses present Inability to tolerate interruption of sedation Inability to communicate fluently in English Need for ongoing EEG monitoring
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Omid Dehzanghi, PhD
Organizational Affiliation
University of Michigan
Official's Role
Principal Investigator
Facility Information:
Facility Name
University of Michigan Health System
City
Ann Arbor
State/Province
Michigan
ZIP/Postal Code
48109
Country
United States

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
21362711
Citation
Happ MB, Garrett K, Thomas DD, Tate J, George E, Houze M, Radtke J, Sereika S. Nurse-patient communication interactions in the intensive care unit. Am J Crit Care. 2011 Mar;20(2):e28-40. doi: 10.4037/ajcc2011433.
Results Reference
background
PubMed Identifier
2403412
Citation
Johnson MM, Sexton DL. Distress during mechanical ventilation: patients' perceptions. Crit Care Nurse. 1990 Jul-Aug;10(7):48-57. No abstract available. Erratum In: Crit Care Nurse 1990 Sep;10(8):72.
Results Reference
background
PubMed Identifier
14984652
Citation
Carroll SM. Nonvocal ventilated patients perceptions of being understood. West J Nurs Res. 2004 Feb;26(1):85-103; discussion 104-12. doi: 10.1177/0193945903259462.
Results Reference
background
PubMed Identifier
8705084
Citation
Baker C, Melby V. An investigation into the attitudes and practices of intensive care nurses towards verbal communication with unconscious patients. J Clin Nurs. 1996 May;5(3):185-92. doi: 10.1111/j.1365-2702.1996.tb00248.x.
Results Reference
background
PubMed Identifier
16137350
Citation
Thomason JW, Shintani A, Peterson JF, Pun BT, Jackson JC, Ely EW. Intensive care unit delirium is an independent predictor of longer hospital stay: a prospective analysis of 261 non-ventilated patients. Crit Care. 2005 Aug;9(4):R375-81. doi: 10.1186/cc3729. Epub 2005 Jun 1.
Results Reference
background
PubMed Identifier
15454792
Citation
Miglietta MA, Bochicchio G, Scalea TM. Computer-assisted communication for critically ill patients: a pilot study. J Trauma. 2004 Sep;57(3):488-93. doi: 10.1097/01.ta.0000141025.67192.d9.
Results Reference
background
PubMed Identifier
23174919
Citation
Maringelli F, Brienza N, Scorrano F, Grasso F, Gregoretti C. Gaze-controlled, computer-assisted communication in Intensive Care Unit: "speaking through the eyes". Minerva Anestesiol. 2013 Feb;79(2):165-75. Epub 2012 Nov 22.
Results Reference
background
PubMed Identifier
15718541
Citation
Smith E, Delargy M. Locked-in syndrome. BMJ. 2005 Feb 19;330(7488):406-9. doi: 10.1136/bmj.330.7488.406. No abstract available.
Results Reference
background
PubMed Identifier
25721542
Citation
Daly JJ, Huggins JE. Brain-computer interface: current and emerging rehabilitation applications. Arch Phys Med Rehabil. 2015 Mar;96(3 Suppl):S1-7. doi: 10.1016/j.apmr.2015.01.007.
Results Reference
background
PubMed Identifier
25623294
Citation
Chaudhary U, Birbaumer N, Curado MR. Brain-machine interface (BMI) in paralysis. Ann Phys Rehabil Med. 2015 Feb;58(1):9-13. doi: 10.1016/j.rehab.2014.11.002. Epub 2015 Jan 8.
Results Reference
background
PubMed Identifier
18571984
Citation
Nijboer F, Sellers EW, Mellinger J, Jordan MA, Matuz T, Furdea A, Halder S, Mochty U, Krusienski DJ, Vaughan TM, Wolpaw JR, Birbaumer N, Kubler A. A P300-based brain-computer interface for people with amyotrophic lateral sclerosis. Clin Neurophysiol. 2008 Aug;119(8):1909-1916. doi: 10.1016/j.clinph.2008.03.034. Epub 2008 Jun 20.
Results Reference
background
PubMed Identifier
25298323
Citation
Sellers EW, Ryan DB, Hauser CK. Noninvasive brain-computer interface enables communication after brainstem stroke. Sci Transl Med. 2014 Oct 8;6(257):257re7. doi: 10.1126/scitranslmed.3007801.
Results Reference
background
PubMed Identifier
25449558
Citation
Marchetti M, Priftis K. Brain-computer interfaces in amyotrophic lateral sclerosis: A metanalysis. Clin Neurophysiol. 2015 Jun;126(6):1255-1263. doi: 10.1016/j.clinph.2014.09.017. Epub 2014 Oct 2.
Results Reference
background
PubMed Identifier
24838215
Citation
Lesenfants D, Habbal D, Lugo Z, Lebeau M, Horki P, Amico E, Pokorny C, Gomez F, Soddu A, Muller-Putz G, Laureys S, Noirhomme Q. An independent SSVEP-based brain-computer interface in locked-in syndrome. J Neural Eng. 2014 Jun;11(3):035002. doi: 10.1088/1741-2560/11/3/035002. Epub 2014 May 19.
Results Reference
background
PubMed Identifier
16317236
Citation
Muller-Putz GR, Scherer R, Brauneis C, Pfurtscheller G. Steady-state visual evoked potential (SSVEP)-based communication: impact of harmonic frequency components. J Neural Eng. 2005 Dec;2(4):123-30. doi: 10.1088/1741-2560/2/4/008. Epub 2005 Oct 25.
Results Reference
background
PubMed Identifier
11355381
Citation
Herrmann CS. Human EEG responses to 1-100 Hz flicker: resonance phenomena in visual cortex and their potential correlation to cognitive phenomena. Exp Brain Res. 2001 Apr;137(3-4):346-53. doi: 10.1007/s002210100682.
Results Reference
background
PubMed Identifier
23269131
Citation
Barr J, Fraser GL, Puntillo K, Ely EW, Gelinas C, Dasta JF, Davidson JE, Devlin JW, Kress JP, Joffe AM, Coursin DB, Herr DL, Tung A, Robinson BR, Fontaine DK, Ramsay MA, Riker RR, Sessler CN, Pun B, Skrobik Y, Jaeschke R; American College of Critical Care Medicine. Clinical practice guidelines for the management of pain, agitation, and delirium in adult patients in the intensive care unit. Crit Care Med. 2013 Jan;41(1):263-306. doi: 10.1097/CCM.0b013e3182783b72.
Results Reference
background
PubMed Identifier
11730446
Citation
Ely EW, Inouye SK, Bernard GR, Gordon S, Francis J, May L, Truman B, Speroff T, Gautam S, Margolin R, Hart RP, Dittus R. Delirium in mechanically ventilated patients: validity and reliability of the confusion assessment method for the intensive care unit (CAM-ICU). JAMA. 2001 Dec 5;286(21):2703-10. doi: 10.1001/jama.286.21.2703.
Results Reference
background
PubMed Identifier
21436536
Citation
Brunner P, Bianchi L, Guger C, Cincotti F, Schalk G. Current trends in hardware and software for brain-computer interfaces (BCIs). J Neural Eng. 2011 Apr;8(2):025001. doi: 10.1088/1741-2560/8/2/025001. Epub 2011 Mar 24.
Results Reference
background
Links:
URL
http://odes-workshop.weebly.com/
Description
BCIBench: A Benchmarking Suite for EEG-based Brain Computer Interface, ODES-11 2014 Workshop on Optimizations for DSP and Embedded Systems, February 15, 2014, Orlando, FL
URL
http://jafari.tamu.edu/wp-content/uploads/2015/12/Omid_EMBC14.pdf
Description
A Novel Stimulation for Multi-Class SSVEP-Based Brain-Computer Interface Using Patterns of Time-Varying Frequencies, International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), August 26-30, 2014, Chicago, IL
URL
http://delivery.acm.org/10.1145/2760000/2750527/p65-dehzangi.pdf?ip=141.214.17.236&id=2750527&acc=ACTIVE%20SERVICE&key=B5D9E165A72B697C%2E0A17827594E6F2C8%2E4D4702B0C3E38B35%2E4D4702B0C3E38B35&CFID=616192599&CFTOKEN=96310905&__acm__=1463419766_b15bc4afc8b8c67ff5215e21bb2e096f
Description
Multi-Modal Biological Driver Monitoring via Ubiquitous Wearable Body Sensor Network, submitted to International Conference on Digital Health, Florence, Italy, 18th - 20th May 2015.
URL
http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4203016
Description
Frequency recognition based on canonical correlation analysis for SSVEP-based BCIs

Learn more about this trial

Brain Computer Interface for Communication in Ventilated Patients

We'll reach out to this number within 24 hrs