search
Back to results

Carbon Dioxide Guided Angiography in Endovascular Abdominal Aortic Aneurysm Repair

Primary Purpose

Abdominal Aortic Aneurysm

Status
Recruiting
Phase
Not Applicable
Locations
Egypt
Study Type
Interventional
Intervention
Carbon Dioxide Angiography
Sponsored by
Mansoura University
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Abdominal Aortic Aneurysm

Eligibility Criteria

undefined - undefined (Child, Adult, Older Adult)All SexesAccepts Healthy Volunteers

Inclusion Criteria:

  • Age more than 18 years old. Abdominal Aortic above Aneurysm candidate for EVAR

Exclusion Criteria:

  • previous abdominal aortic surgery, , mycotic aneurysm and secondary intervention

Sites / Locations

  • MansouraRecruiting

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

Endovascular abdominal aortic aneurysm repair

Arm Description

a type of endovascular surgery used to treat pathology of the aorta, most commonly an abdominal aortic aneurysm (AAA).

Outcomes

Primary Outcome Measures

Validity of Carbon Dioxide angiography in Visualizing of Renal and hypogastric arteries.
Visualizing of Renal and hypogastric arteries.
Validity of Carbon Dioxide angiography in Visualizing Neck of the aneurysm measurements.
measuring the supra renal and infra renal neck measurements
Validity of Carbon Dioxide angiography in Visualizing Endoleaks
Endoleaks occur when blood leaks back into an aneurysm sac following an endovascular aneurysm repair (EVAR) procedure-one of the procedure's most common complications.

Secondary Outcome Measures

Safety of Carbon Dioxide angiography at Endovascular aortic aneurysm repair
Adverse effects of Carbon Dioxide angiography

Full Information

First Posted
June 21, 2020
Last Updated
July 16, 2022
Sponsor
Mansoura University
search

1. Study Identification

Unique Protocol Identification Number
NCT04444999
Brief Title
Carbon Dioxide Guided Angiography in Endovascular Abdominal Aortic Aneurysm Repair
Official Title
Carbon Dioxide Guided Angiography in Endovascular Abdominal Aortic Aneurysm Repair
Study Type
Interventional

2. Study Status

Record Verification Date
July 2022
Overall Recruitment Status
Recruiting
Study Start Date
November 1, 2019 (Actual)
Primary Completion Date
January 1, 2023 (Anticipated)
Study Completion Date
January 1, 2023 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Mansoura University

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
Endovascular aneurysm repair (EVAR) has lower short-term morbidity and mortality than open surgery. Intra-arterial contrast agents are an important component of successful EVAR as the tool of choice for preoperative evaluation of aortic aneurysm morphology as well as precise sizing and intraoperative visualization of the ostia of the renal and hypogastric arteries for graft replacement. Although iodinated contrast (IC) is overwhelmingly the most common contrast agent, the perioperative use of IC agents is not recommended in patients with renal dysfunction or allergies to IC The aim of this study was to evaluate feasibility, efficacy and safety of carbon dioxide (CO2) digital subtraction angiography (DSA) to guide endovascular aneurysm repair (EVAR) in a cohort of patients with abdominal aortic aneurysm
Detailed Description
INTRODUCTION: Endovascular aneurysm repair (EVAR) has lower short-term morbidity and mortality than open surgery. Intra-arterial contrast agents are an important component of successful EVAR as the tool of choice for preoperative evaluation of aortic aneurysm morphology as well as precise sizing and intraoperative visualization of the ostia of the renal and hypogastric arteries for graft replacement. Although iodinated contrast (IC) is overwhelmingly the most common contrast agent, the perioperative use of IC agents is not recommended in patients with renal dysfunction or allergies to IC. Many strategies have been proposed with the aim of reducing IC developed, such as the use of intravascular ultrasound, high-quality 3-dimensional imaging techniques, and fusion of preoperative and intraoperative imaging. However, despite reports of various methods of renal protection, including the use of perioperative hydration, acetylcysteine, mannitol, dopamine, and fenoldopam, the effects of these methods are controversial. Carbon dioxide (CO2)-guided angiography is an alternative contrast approach first described for diagnostic purposes by Hawkins. Although many studies have demonstrated the safety and effectiveness of CO2-EVAR and its noninferiority to Iodinated Contrast Angiography during EVAR. Intravascular ultrasound (IVUS) has been used as an alternative to IACA(intra-arterial contrast agents). Originally, IVUS images had low accuracy, but recent improvements have resulted in very high-quality images of intra-aortic structures, which makes the use of IACA(intra-arterial contrast agents) almost unnecessary. An additional advantage of IVUS is that it facilitates the precise placement of stent grafts, because it is more accurate in locating hypogastric arteries and renal arteries which have parallax from the anteroposterior (A-P) view rather than from angiography. In this study, investigators will compare Carbon Dioxide Guided Angiography in relation to Iodinated Contrast Angiography during EVAR. Aim of the work The aim of this study was to evaluate feasibility, efficacy and safety of carbon dioxide (CO2) digital subtraction angiography (DSA) to guide endovascular aneurysm repair (EVAR) in a cohort of patients with abdominal aortic aneurysm. Outcome Primary outcomes: Validity of CO2 in Visualizing of Renal and hypogastric arteries. Neck of the aneurysm measurements. Endoleaks Secondary outcomes: Safety of CO2 Patients and methods Study location: The study will be conducted at the department of vascular surgery in Mansoura university hospitals Study population: The study will be conducted in patients with Abdominal Aortic Aneurysm. Type of the study: Evaluation of diagnostic imaging. Duration of therapy: Two year 2019-2021. Sample size: It will include all patients presented to our department fulfilling the inclusion criteria; sample size will be 50 patients. n=(Z^2 p(1-p))/d^2 Where: Z= 1.96 at 95% confidence level, P= expected prevalence, d= precision (margin of error) Inclusion criteria Age 18 years old. Less than 50 years old Abdominal Aortic above Aneurysm candidate for EVAR. Exclusion criteria: previous abdominal aortic surgery, , mycotic aneurysm and secondary intervention. Data collection: The demographics, Symptoms and preoperative clinical data will be collected Consent: Patients after signing informed consent that possible complication from the procedure ought to happen and what are the alternatives. Technique: All procedures are performed using two angiographic methods in each procedure: automated conventional ICM digital subtraction angiography (DSA) and CO2 automated DSA, in a Philips hybrid operating theatre. IVUS method (instead of ICM) will be used in chronc kidney disease patients Proximal and distal sealing zone are evaluated before and after endograft deployment, for diagnostic and completion evaluation respectively, by both imaging methods. The presence of endoleaks will be also evaluated at the completion angiography, by both methods. The angiographic results that will be obtained by CO2 and ICM will be compared. Preoperative imaging will be performed by contrast enhanced computed tomography (CTA); analyzed with dedicated software for vessels analysis. centerline will be manually calculated by selecting points at the center of aorta and iliac arteries using multi planar reconstructions (axial, sagittal and coronal views). Abdominal aortic aneurysm volumetric evaluation is performed by selecting points of the external aortic wall (AAA total volume) and of the internal aortic lumen (AAA true luminal volume) from the lower renal artery to the aortic bifurcation, using a dedicated software of volumetric CTA analysis (3MensioTM). Conventional contrast media angiography: Iodinate contrast media DSA will be performed by automatic and manual injection. For the automatic DSA, isotonic ICM is injected trough a pigtail catheter (5F/65 mm length) positioned just above the renal arteries, using automated injector. During each procedure two automated ICM DSA, with a volume of 20 mL at a rate of 14 mL/s, are performed: a diagnostic injection before the deployment of the endograft, in order to visualize the proximal sealing zone, the aortic bifurcation and the distal sealing zone, and a completion angiography to confirm the technical success and to evaluate the presence of endoleaks. Manual retrograde injections (3 mL ICM each) are performed from the femoral access by 10 F /11mm length sheet to visualize the hypogastric arteries origin and confirm the distal sealing zone just before the limb deployment. Intravascular ultrasound (IVUS) will have been used as an alternative to iodinated contrast in if the iodinated contrast contraindicated patients. The IVUS procedure steps used are summarized here. First, the bilateral common femoral arteries were exposed and a 9-F sheath introducer the lowest profile adjusted to the 8.2-F of the outer diameter of the IVUS transducer is inserted retrograde. A soft guidewire is used to introduce a calibrated pigtail catheter, graduated in centimetres, up to the thoracic aortic arch. The guidewire is then replaced with a stiff wire followed by IVUS insertion. IVUS is used to locate the renal arteries and hypogastric arteries by mapping them on the monitor; then, IVUS is switched to the calibrated catheter to determine the length of the main body. IVUS is introduced using the monorail system. After deployment of the main body, the soft guidewire is cannulated into the contralateral limb. The guidewire is replaced with the stiff wire, followed by the IVUS insertion. The length of the contralateral site is determined by measuring the length from the edge of the main body to the site of the hypogastric ostium. Using the same technique, investigators will estimate the stent graft length with the calibrated catheter. Automated carbon dioxide angiography: Patients are placed in the Trendelenburg position with the feet elevated of 10 º degrees. Carbon Dioxide automatic injection will be performed by digital Angiodroid injection system (Angiodroid SRL, San Lazzaro, Bologna, Italy) connected to the sidearm of 10F/11mm length sheet. Ten milliliters of CO2 are infused to fill the tubing with gas and eliminate the air. Then by apposite manipulation of the stopcocks, the sheath is back-bled through its sidearm, and CO2 infused, creating a blood-CO2 interface with no air in the system 12. The 10F sheet is positioned at the level of the external iliac artery at the contralateral access of the main body. Each injection volume will be 100 mL of CO2 and the injection pressure is 300 mmHg (Figure 1D). To avoid gas fragmentation, the catheter will be purged prior to each injection and delivery is in a continuous controlled fashion. During each procedure a diagnostic evaluation, before the deployment of the endograft, an angiography to visualize the hypogastric arteries origin and a completion angiography, is performed after the positioning of the endograft. Both the endograft deployment angiography and the completion angiography will be performed maintaining a constant blood systolic pressure, between 100 and 120 mmHg. Operative technique: All the procedures are performed in a Philips hybrid operating theatre and all angiograms are obtained using the Integris Allura 12 DSA. Bilateral common femoral artery access is obtained through surgical cut down under spinal or general anesthesia. According with the vertebral bone landmarks, identified pre-operatively, the main-body endograft is advanced up to the juxta-renal aortic segment. An angiographic evaluation is performed before the endograft deployment. After contra-lateral gate cannulation, a marked pig tail will be used to measure the iliac limb length and to identify the origin of the hypogastric artery from the contralateral access. When a trimodular endograft is deployed, the same maneuver will be performed for the ipsilateral access. Patients considered at high risk for persistent type II endoleak (ELII) underwent intraoperative AAA sac embolization as reported in a previous experience. After the endograft deployment a completion angiography is performed in all cases. Endpoints and definition Primary endpoints are to determine the efficacy of CO2 automated DSA in proximal/distal sealing zone evaluation and endoleaks detection, in comparison with ICM. Secondary endpoint is to evaluate the safety of CO2 standardized automated injection (any side effects). Patients are defined fit for standard EVAR when proximal and distal neck length was ≥ 15 mm and aortic neck β angle and angles at the level of iliac arteries were < 60°. Diagnostic angiography is defined as the first angiography performed with the main body advanced at the level of the lower renal artery according to bone landmarks, just before its deployment, in order to visualize the optimal proximal sealing zone. The intraoperative proximal sealing zone evaluation is defined effective when the lower renal artery and the proximal aortic neck just below it, are correctly visualized. The intraoperative distal sealing zone evaluation is defined effective if the origin of the hypogastric artery and the distal segment of the common iliac artery just above it, are visualized. Technical success (TS) is defined as the complete endograft deployment with patency of renal and hypogastric arteries, absence of type I/III endoleaks and iliac leg kinking or stenosis, no conversion to OR or 24-hour mortality. Endoleaks are defined according to White and May classification . CO2 side effects (CO2 narcosis) are defined as any adverse events correlate to CO2 automated injection. As reported in literature, abdominal pain, transient hypotension, nausea, ischemic colitis occurring intraoperatively or within 30 minutes from the procedure, are considered adverse events correlate to CO2. Follow up Every patient will be followed first week and month, then every 3 months For at least 6 months. Evaluation made by CTA or duplex ultrasonography Statistical analysis: The clinical characteristics of the study population is summarized by descriptive statistics. The following tests Fisher's exact test and the Mann-Whitney U test; used for categorical and continuous variables, respectively. Sensitivity and specificity will measures of the performance of the test Individual differences were considered to be statistically significant at p < 0.05 Continuous data are presented as median and interquartile range (IQR).

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Abdominal Aortic Aneurysm

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Model Description
carbon dioxide (CO2) digital subtraction angiography (DSA) to guide endovascular aneurysm repair (EVAR(
Masking
None (Open Label)
Allocation
N/A
Enrollment
50 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
Endovascular abdominal aortic aneurysm repair
Arm Type
Experimental
Arm Description
a type of endovascular surgery used to treat pathology of the aorta, most commonly an abdominal aortic aneurysm (AAA).
Intervention Type
Procedure
Intervention Name(s)
Carbon Dioxide Angiography
Intervention Description
• Automated carbon dioxide angiography: Patients are placed in the Trendelenburg position with the feet elevated of 10 º degrees. Carbon Dioxide automatic injection will be performed by digital Angiodroid injection system
Primary Outcome Measure Information:
Title
Validity of Carbon Dioxide angiography in Visualizing of Renal and hypogastric arteries.
Description
Visualizing of Renal and hypogastric arteries.
Time Frame
6 months
Title
Validity of Carbon Dioxide angiography in Visualizing Neck of the aneurysm measurements.
Description
measuring the supra renal and infra renal neck measurements
Time Frame
6 months
Title
Validity of Carbon Dioxide angiography in Visualizing Endoleaks
Description
Endoleaks occur when blood leaks back into an aneurysm sac following an endovascular aneurysm repair (EVAR) procedure-one of the procedure's most common complications.
Time Frame
6 months
Secondary Outcome Measure Information:
Title
Safety of Carbon Dioxide angiography at Endovascular aortic aneurysm repair
Description
Adverse effects of Carbon Dioxide angiography
Time Frame
6 months

10. Eligibility

Sex
All
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria: Age more than 18 years old. Abdominal Aortic above Aneurysm candidate for EVAR Exclusion Criteria: previous abdominal aortic surgery, , mycotic aneurysm and secondary intervention
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Mosaad A Soliman, P.h.D
Phone
01001535711
Ext
002
Email
soliman_mosaad@hotmail.com
Facility Information:
Facility Name
Mansoura
City
Mansoura
State/Province
Mansoura University
ZIP/Postal Code
35111
Country
Egypt
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Mansoura UH Hospitals
Phone
0502202876
Ext
0200
Email
muh@mans.edu.eg
First Name & Middle Initial & Last Name & Degree
Mansoura UH Hospitals
Phone
050 2202750
Ext
0200
Email
muh@mans.edu.eg

12. IPD Sharing Statement

Plan to Share IPD
No

Learn more about this trial

Carbon Dioxide Guided Angiography in Endovascular Abdominal Aortic Aneurysm Repair

We'll reach out to this number within 24 hrs