Catheters Dysfunction Rate After Instillation of Ethanol 60% Lock Solution in Tunneled Silicone Catheter of Chronic Hemodialysis Patients (Ethanol)
Primary Purpose
End Stage Renal Failure, Hemodialysis
Status
Terminated
Phase
Phase 2
Locations
France
Study Type
Interventional
Intervention
Ethanol
Sponsored by
About this trial
This is an interventional treatment trial for End Stage Renal Failure, Hemodialysis focused on measuring Ethanol, lock solution, infection
Eligibility Criteria
Inclusion Criteria:
- Patients of both genders, over 18 years,
- Chronic hemodialysis 3 times a week, with two tunnel silicone catheters since at least 15 days,
- Written informed consent
- Social security
Exclusion Criteria:
- Antibiotic therapy during selection phase,
- Partial or complete catheter occlusion during selection phase,
- Venous pressure at dialysis connection > 300 mmHg,
- Known allergy to ethanol,
- Patient involved in any other clinical trial or in the exclusion period
- Severe co-morbidity
- Acute or chronic infectious disease
- Evolutive neoplasia,
- HIV, HCV positive serology at inclusion,
- Scheduled surgery
Sites / Locations
- Lacarin
Outcomes
Primary Outcome Measures
The catheters dysfunction rate
Secondary Outcome Measures
The dialysis quality is also examined (urea reduction rate, total ultrafiltration)
Full Information
NCT ID
NCT00563342
First Posted
November 22, 2007
Last Updated
October 7, 2008
Sponsor
University Hospital, Clermont-Ferrand
1. Study Identification
Unique Protocol Identification Number
NCT00563342
Brief Title
Catheters Dysfunction Rate After Instillation of Ethanol 60% Lock Solution in Tunneled Silicone Catheter of Chronic Hemodialysis Patients
Acronym
Ethanol
Official Title
Catheters Dysfunction Rate After Instillation of Ethanol 60% Lock Solution in Tunneled Silicone Catheter of Chronic Hemodialysis Patients
Study Type
Interventional
2. Study Status
Record Verification Date
October 2008
Overall Recruitment Status
Terminated
Study Start Date
June 2007 (undefined)
Primary Completion Date
March 2008 (Actual)
Study Completion Date
March 2008 (Actual)
3. Sponsor/Collaborators
Name of the Sponsor
University Hospital, Clermont-Ferrand
4. Oversight
5. Study Description
Brief Summary
The primary objective of the study is to examine the risk of catheter dysfunction during the dialysis session that follows the instillation of ethanol 60% as lock solution in tunneled silicone catheters of end stage renal failure patients treated by hemodialysis.
The catheters dysfunction rate is the primary outcome. The dysfunction is defined as partial or complete occlusion or infection associated with dialysis catheter.
As a secondary outcome, the dialysis quality is also examined (urea reduction rate, total ultrafiltration)
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
End Stage Renal Failure, Hemodialysis
Keywords
Ethanol, lock solution, infection
7. Study Design
Primary Purpose
Treatment
Study Phase
Phase 2
Interventional Study Model
Single Group Assignment
Allocation
N/A
Enrollment
40 (Anticipated)
8. Arms, Groups, and Interventions
Intervention Type
Drug
Intervention Name(s)
Ethanol
Intervention Description
Examine the risk of catheter dysfunction during the dialysis session that follows the instillation of ethanol 60% as lock solution in tunneled silicone catheters of end stage renal failure patients treated by hemodialysis
Primary Outcome Measure Information:
Title
The catheters dysfunction rate
Time Frame
as partial or complete occlusion or infection associated with dialysis catheter
Secondary Outcome Measure Information:
Title
The dialysis quality is also examined (urea reduction rate, total ultrafiltration)
Time Frame
as partial or complete occlusion or infection associated with dialysis catheter
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Patients of both genders, over 18 years,
Chronic hemodialysis 3 times a week, with two tunnel silicone catheters since at least 15 days,
Written informed consent
Social security
Exclusion Criteria:
Antibiotic therapy during selection phase,
Partial or complete catheter occlusion during selection phase,
Venous pressure at dialysis connection > 300 mmHg,
Known allergy to ethanol,
Patient involved in any other clinical trial or in the exclusion period
Severe co-morbidity
Acute or chronic infectious disease
Evolutive neoplasia,
HIV, HCV positive serology at inclusion,
Scheduled surgery
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Bertrand Souweine, Pr
Official's Role
Principal Investigator
Facility Information:
Facility Name
Lacarin
City
Clermont-Ferrand
ZIP/Postal Code
63000
Country
France
12. IPD Sharing Statement
Citations:
PubMed Identifier
27473868
Citation
Coupez E, Timsit JF, Ruckly S, Schwebel C, Gruson D, Canet E, Klouche K, Argaud L, Bohe J, Garrouste-Orgeas M, Mariat C, Vincent F, Cayot S, Cointault O, Lepape A, Darmon M, Boyer A, Azoulay E, Bouadma L, Lautrette A, Souweine B. Guidewire exchange vs new site placement for temporary dialysis catheter insertion in ICU patients: is there a greater risk of colonization or dysfunction? Crit Care. 2016 Jul 30;20(1):230. doi: 10.1186/s13054-016-1402-6.
Results Reference
derived
Learn more about this trial
Catheters Dysfunction Rate After Instillation of Ethanol 60% Lock Solution in Tunneled Silicone Catheter of Chronic Hemodialysis Patients