search
Back to results

Cellulose Triacetate Dialyzer in Hemodiafiltration-online

Primary Purpose

Chronic Kidney Disease Requiring Chronic Dialysis

Status
Completed
Phase
Not Applicable
Locations
Spain
Study Type
Interventional
Intervention
Asymmetric cellulose triacetate (ATA™)
Sponsored by
Hospital Universitario Infanta Leonor
About
Eligibility
Locations
Outcomes
Full info

About this trial

This is an interventional treatment trial for Chronic Kidney Disease Requiring Chronic Dialysis focused on measuring Asymmetric cellulose triacetate, Biocompatibility, Hemodiafiltration on-line, Convective volume, Adequacy

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion

  • Criteria:being over 18 years old, being treated with OLHDF for more than 4 weeks with 3 weekly sessions and sign an informed consent form.

Exclusion Criteria:

  • pregnancy and illness that would make the patient's death predictable in less than 4 weeks.

Sites / Locations

  • Marta Albalate Ramón

Outcomes

Primary Outcome Measures

Performance of asymmetric cellulose triacetate (ATA™)
Describing in vivo depurative efficacy of asymmetric cellulose triacetate (ATA™) measuring Kt, infusion volumen and clearance of RR of different molecules
Biocompatibility of asymmetric cellulose triacetate (ATA™)
Studying its acute (measuring complement and leukocites) and chronic (measuring monocytes subpopulationsand interleukines)
Clinical behaviour of ATA
Studuying alarm or clínical problemas related with dialyzer

Secondary Outcome Measures

Full Information

First Posted
March 27, 2017
Last Updated
April 3, 2017
Sponsor
Hospital Universitario Infanta Leonor
search

1. Study Identification

Unique Protocol Identification Number
NCT03105817
Brief Title
Cellulose Triacetate Dialyzer in Hemodiafiltration-online
Official Title
Study of Cellulose Triacetate Dialyzer (Solacea™): in Vivo Behavior in Hemodiafiltration-online
Study Type
Interventional

2. Study Status

Record Verification Date
March 2017
Overall Recruitment Status
Completed
Study Start Date
February 1, 2016 (Actual)
Primary Completion Date
July 10, 2016 (Actual)
Study Completion Date
August 14, 2016 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Hospital Universitario Infanta Leonor

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
In post-dilution haemodiafiltration only synthetic membranes have been used to date. The allergy problems described with these membranes require the development of other membranes capable of performing this treatment. We describe in vivo performance and behaviour of an asymmetric cellulose triacetate(ATA™) membrane, to identify its depurative effectiveness and ease of use in clinical practice, as well as evaluate its biocompatibility in a single haemodialysis session (acute biocompatibility) and after one month of treatment (chronic).
Detailed Description
An interventional study was performed in 3 hemodialysis hospital units (La Princesa University Hospital, Príncipe de Asturias University Hospital and Infanta Leonor University Hospital, Community of Madrid, Spain) in which the usual dialyzer that each patient had for OLHDF was replaced with the Solacea™ dialyzer keeping the rest of the parameters unchanged. The study (LIB 09/2015) was reviewed and approved by the CEIC of the Príncipe de Asturias University Hospital. Design of the study Each patient underwent 12 sessions of haemodialysis with the usual schedule and monitor: 5008 of Fresenius (n=14), AK200US (n=5) and Artis of Gambro (n=3) and DBB007 of Nikkiso (n=1) all suitable for OLHDF, although with different convective transport control systems. The nursing staff connected the automatic OLHDF system. In the case where the system was Ultracontrol® (Gambro monitors) if alarm of PTM> 300 mmHg or system pressure (PSist)> 700 mmHg appeared and were not solved, Ultracontrol® would be withdrawn and the pressure-control system would be used. Data to be collected: Demographic and dialysis data Demographic: sex, age, underlying disease, time in OLHDF, type of vascular access: fistula (AFV) and catheter (CT). Dialysis Data: Monitor, dialysis fluid composition, sodium conductivity and bicarbonate concentration, dialysis fluid flow (Qd, ml min), liquid temperature, heparin type and dosage. Each dialysis session: effective time (TE, min), blood flow (Qb, ml min), ultra-filtrated volume to achieve dry weight (UF, l/session), Vinf (l/session), infusion rate, (Qi, ml/min) Kt (l / session), maximum PTM and maximum Psist in Ultracontrol® (mmHg) and the technical complications, alarms and coagulation problems of the system that may appear. The filtration fraction (FF) was calculated as the percentage of Qi relative to Qb. The convective volume (Vconv) was defined as the total ultra-filtrated volume, which is the sum of VI and UF.7 Analytical determinations Blood - On the first and last day of the study pre-dialysis samples were taken for the measurement of monocytes, IL-6 and IL-1β. On the interval day of the first week, 3 blood samples were taken: 1st) at the beginning (CI), 2nd) at 30 min (CM) and the 3rd) at the end of the dialysis session (CP). In CI and CP the following parameters were measured: haemoglobin, proteins and albumin, urea, phosphorus, creatinine, uric acid, β2-microglobulin, myoglobin and retinol transport protein (RTP). Leukocytes, platelets, C3a and C5a were quantified in CI and CM. --- Laboratory determinations - General biochemical data: haemoglobin, proteins, albumin, urea, phosphorus, reactive protein C (PCR), creatinine and uric acid, β2-microglobulin, myoglobin, and (RTP) were determined with the usual analyser of each hospital. - Determinations of monocytes, complement, IL-6 and IL-1β were performed in the laboratory of the University of Alcalá: Activation of plasma complement using a sandwich ELISA: Determination of C3a and C5a activation was performed on platelet rich plasma samples using commercially available ELISA kits C3a Elabscience (Wuhan, P.R. China) and ELISA C5a RayBiotech (Norcross, Georgia). Determination of interleukin concentration in serum using a sandwich ELISA: IL-6 and IL-1β concentrations were measured in serum samples obtained from whole blood and stored at -80 ° C until use. Both kits used were supplied by Abcam (Cambridge, UK) Determination of monocyte subpopulations: The different subpopulations of circulating monocytes in peripheral blood were identified by flow cytometry (FACSCalibur™, Becton Dickinson, San Jose, CA, USA). First of all, the monocyte population was selected according to size (FSC/forward scatter) and granularity (SSC/side scatter) and then the different subpopulations were selected by double immunofluorescence according to staining with the anti-CD14 conjugated Tricolor (monoclonal antibodies TuK4) and anti-CD16 conjugated FITC (monoclonal antibodies 3G8). Both antibodies and their respective isotype controls were purchased from Life Technologies Invitrogen (California, USA). The analysis was performed with the Cyflogic program. Calculations The percentages of reduction (RR) were calculated with the formula: RR (%) = [(Cpre - Cpos) / Cpre] x 100, where Cpre and Cpos are the concentrations of the analysed substances pre- and post-dialysis. For protein bound substances and β2-microglobulin concentrations at the end of the session were corrected for haemoconcentration by a correction factor (FC) based on plasma protein concentration (PT): FC = PTpre / PTpos, where PTpre and PTpos are the total concentration of proteins pre-dialysis and post-dialysis. --- Statistical analysis All data was collected in a database (SPSS version 15). Each value was obtained with the average of the values obtained in the different sessions or analytical determinations. For the statistical analysis, descriptive tools were used, showing the average (standard deviation), median, quartiles or percentages as appropriate. For the comparison of two independent continuous variables, the Student t test for paired samples was used. For the comparison of more than two quantitative variables the ANOVA test was used. The p <0.05 was considered statistically significant.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Chronic Kidney Disease Requiring Chronic Dialysis
Keywords
Asymmetric cellulose triacetate, Biocompatibility, Hemodiafiltration on-line, Convective volume, Adequacy

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
Non-Randomized
Enrollment
23 (Actual)

8. Arms, Groups, and Interventions

Intervention Type
Device
Intervention Name(s)
Asymmetric cellulose triacetate (ATA™)
Other Intervention Name(s)
Solacea™
Intervention Description
Each patient underwent 12 sessions of haemodialysis with the usual schedule, changing the usual dialyzer
Primary Outcome Measure Information:
Title
Performance of asymmetric cellulose triacetate (ATA™)
Description
Describing in vivo depurative efficacy of asymmetric cellulose triacetate (ATA™) measuring Kt, infusion volumen and clearance of RR of different molecules
Time Frame
One month
Title
Biocompatibility of asymmetric cellulose triacetate (ATA™)
Description
Studying its acute (measuring complement and leukocites) and chronic (measuring monocytes subpopulationsand interleukines)
Time Frame
One month
Title
Clinical behaviour of ATA
Description
Studuying alarm or clínical problemas related with dialyzer
Time Frame
One month

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:being over 18 years old, being treated with OLHDF for more than 4 weeks with 3 weekly sessions and sign an informed consent form. Exclusion Criteria: pregnancy and illness that would make the patient's death predictable in less than 4 weeks.
Facility Information:
Facility Name
Marta Albalate Ramón
City
Madrid
Country
Spain

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
10917004
Citation
Maduell F, Navarro V, Hernandez-Jaras J, Calvo C. [Comparison of dialyzers in on-line hemodiafiltration]. Nefrologia. 2000 May-Jun;20(3):269-76. Spanish.
Results Reference
result
PubMed Identifier
27951571
Citation
Sunohara T, Masuda T. Fundamental Characteristics of the Newly Developed ATA Membrane Dialyzer. Contrib Nephrol. 2017;189:215-221. doi: 10.1159/000451044. Epub 2016 Dec 12.
Results Reference
result
PubMed Identifier
25036066
Citation
Sanchez-Villanueva RJ, Gonzalez E, Quirce S, Diaz R, Alvarez L, Menendez D, Rodriguez-Gayo L, Bajo MA, Selgas R. Hypersensitivity reactions to synthetic haemodialysis membranes. Nefrologia. 2014;34(4):520-5. doi: 10.3265/Nefrologia.pre2014.May.12552. English, Spanish.
Results Reference
result
PubMed Identifier
27951569
Citation
Mineshima M. Optimal Design of Dialyzers. Contrib Nephrol. 2017;189:204-209. doi: 10.1159/000450802. Epub 2016 Dec 12.
Results Reference
result
PubMed Identifier
21865788
Citation
Sunohara T, Masuda T. Cellulose triacetate as a high-performance membrane. Contrib Nephrol. 2011;173:156-163. doi: 10.1159/000329055. Epub 2011 Aug 8.
Results Reference
result

Learn more about this trial

Cellulose Triacetate Dialyzer in Hemodiafiltration-online

We'll reach out to this number within 24 hrs