search
Back to results

Clinical Assessment of Computer-assisted PEEK Versus Conventional Titanium Plates on Mandibular Body Fractures

Primary Purpose

Fracture Mandible, Mandibular Fractures

Status
Unknown status
Phase
Not Applicable
Locations
Egypt
Study Type
Interventional
Intervention
Titanium plate fixation
Custom made PEEK plate fixation
Sponsored by
Cairo University
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Fracture Mandible focused on measuring Mandibular body fractures, PEEK plates, titanium plates.

Eligibility Criteria

undefined - undefined (Child, Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. Patients with at least a unilateral body fracture indicated for Open reduction internal fixation alone or in combination with fracture elsewhere in the mandible or midface.
  2. All ages and both sexes were included in this study.
  3. Patients should be free from any systemic disease that may affect normal healing of bone, and predictable outcome.
  4. Patients with good general condition allowing major surgical procedure under general anesthesia.
  5. Patients with physical and psychological tolerance.

Exclusion Criteria:

  1. Patients with physical and psychological intolerance. Because psychological stress will affect the immune system and general health.
  2. Patients with systemic diseases like uncontrolled diabetes mellitus. Because uncontrolled diabetes mellitus has a negative impact on normal bone healing.
  3. Patients with old and/or mal-union fractures. As they will affect accuracy of reduction of the fractured segments.
  4. Patient with bad oral hygiene. As it has an influence on normal osseous healing

Sites / Locations

  • Faculty of Oral and Dental Medicine -Cairo UniversityRecruiting

Arms of the Study

Arm 1

Arm 2

Arm Type

Experimental

Active Comparator

Arm Label

Custom made PEEK plate fixation

Titanium plate fixation

Arm Description

Open Reduction Internal Fixation using Custom made PEEK plates.

Open Reduction Internal Fixation using conventional titanium plating system.

Outcomes

Primary Outcome Measures

Postoperative occlusion
Restoration of normal patient occlusion will be assessed using Visual analog scale (VAS) (0-10)

Secondary Outcome Measures

Accuracy of the planned reduction
The accuracy of computer assisted PEEK custom made plates in open reduction and internal fixation of mandibular body fractures will be assessed using Mimics software, measuring unit (mm)
Wound dehiscence
Wound infection will be assessed via clinical assessment, measuring unit (Binary yes/no)
The need for 2nd surgery
Redo surgery will be assessed via clinical assessment, measuring unit (Binary yes/no)
Operative time
Surgical time will be assessed via clinical assessment, measuring unit (hours)

Full Information

First Posted
March 2, 2018
Last Updated
March 8, 2018
Sponsor
Cairo University
search

1. Study Identification

Unique Protocol Identification Number
NCT03466190
Brief Title
Clinical Assessment of Computer-assisted PEEK Versus Conventional Titanium Plates on Mandibular Body Fractures
Official Title
Clinical Assessment of Postoperative Occlusion in Patient With Mandibular Body Fractures Reduced and Fixed With Computer-assisted Polyether Ether Ketone (PEEK) Custom Made Plates Versus Conventional Titanium Plates (RCT)
Study Type
Interventional

2. Study Status

Record Verification Date
March 2018
Overall Recruitment Status
Unknown status
Study Start Date
August 2, 2017 (Actual)
Primary Completion Date
March 2, 2019 (Anticipated)
Study Completion Date
March 2, 2019 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Cairo University

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
Yes

5. Study Description

Brief Summary
Two groups of patients with mandibular body fractures indicated for Open reduction internal fixation alone or in combination with fractures elsewhere in the mandible or midface. First group will be subjected to traditional titanium internal rigid fixation. Second group will be subjected to custom made PEEK plates.
Detailed Description
Two groups of patients with mandibular body fractures indicated for Open reduction internal fixation alone or in combination with fractures elsewhere in the mandible or midface. First group will be subjected to traditional titanium internal rigid fixation. Second group will be subjected to custom made PEEK plates. Inclusion criteria: All subjects were required: Patients with at least a unilateral body fracture indicated for Open reduction internal fixation alone or in combination with fracture elsewhere in the mandible or midface. All ages and both sexes were included in this study. Patients should be free from any systemic disease that may affect normal healing of bone, and predictable outcome. Patients with good general condition allowing major surgical procedure under general anesthesia. Patients with physical and psychological tolerance. Exclusion criteria: Patients with high risk systemic diseases like uncontrolled diabetes . As uncontrolled diabetes has a negative impact on normal bone healing. Patients with old fractures. As they will affect accuracy of reduction of the fractured segments. Patients with physical and psychological intolerance. As psychological stress will affect the immune system and patient's fitness including healing capacity. Interventions: Eligible patients will be randomized in equal proportions between the study group (PEEK custom made plates) and the control group (titanium plates). A- Computer-assisted PEEK custom made plates: All cases will undergo surgery under general anesthesia. Exposure of the fractured segments will be done using a standardized surgical approach. The fractured segments will be reduced in normal anatomic position guided by customized plate. Fracture fragments will be fixed using PEEK custom made plate utilizing 2.0 mm screws. B- Conventional titanium plates: All cases will undergo surgery under general anesthesia. Exposure of the fractured segments will be done using a standardized surgical approach. Inter-maxillary fixation will be done. The fractured segments will be reduced in normal anatomic position guided by occlusion. The fracture fragments will be fixed using 2.3 titanium plate on the inferior border and 2.0 titanium plate on the superior border utilizing bone screws. Follow up: Clinical evaluation will be performed at the first week postoperative. Computed tomography will be performed at the first week postoperative then patients will be recalled for clinical evaluation every week for one month. Final follow up visit will be at 3 months postoperative.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Fracture Mandible, Mandibular Fractures
Keywords
Mandibular body fractures, PEEK plates, titanium plates.

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Model Description
A Randomized clinical trial. A trial will be carried out in hospital of Oral and Maxillofacial surgery department- Faculty of Oral and Dental Medicine Cairo University Equal randomization: participants with equal probabilities for intervention. Positive controlled: Both groups receiving treatment. Parallel group study: Each group of patients receives a single treatment simultaneously.
Masking
None (Open Label)
Masking Description
Because the two interventions used in this trial are clearly different and easily recognized by the participants and investigators, neither the investigator nor participants can be blinded
Allocation
Randomized
Enrollment
20 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
Custom made PEEK plate fixation
Arm Type
Experimental
Arm Description
Open Reduction Internal Fixation using Custom made PEEK plates.
Arm Title
Titanium plate fixation
Arm Type
Active Comparator
Arm Description
Open Reduction Internal Fixation using conventional titanium plating system.
Intervention Type
Procedure
Intervention Name(s)
Titanium plate fixation
Other Intervention Name(s)
Conventional titanium plates
Intervention Description
Under General Anesthesia, exposure of the fractured mandibular body segments will be done using a standardized surgical approach. Open Reduction Internal Fixation using conventional titanium plates will be performed.
Intervention Type
Procedure
Intervention Name(s)
Custom made PEEK plate fixation
Other Intervention Name(s)
Computer-assisted PEEK plate fixation
Intervention Description
Under General Anesthesia, exposure of the fractured mandibular body segments will be done using a standardized surgical approach. Open Reduction Internal Fixation using custom made PEEK plates will be performed.
Primary Outcome Measure Information:
Title
Postoperative occlusion
Description
Restoration of normal patient occlusion will be assessed using Visual analog scale (VAS) (0-10)
Time Frame
1 month postoperative
Secondary Outcome Measure Information:
Title
Accuracy of the planned reduction
Description
The accuracy of computer assisted PEEK custom made plates in open reduction and internal fixation of mandibular body fractures will be assessed using Mimics software, measuring unit (mm)
Time Frame
1st week
Title
Wound dehiscence
Description
Wound infection will be assessed via clinical assessment, measuring unit (Binary yes/no)
Time Frame
1 month postoperative
Title
The need for 2nd surgery
Description
Redo surgery will be assessed via clinical assessment, measuring unit (Binary yes/no)
Time Frame
1 month postoperative
Title
Operative time
Description
Surgical time will be assessed via clinical assessment, measuring unit (hours)
Time Frame
During operation

10. Eligibility

Sex
All
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Patients with at least a unilateral body fracture indicated for Open reduction internal fixation alone or in combination with fracture elsewhere in the mandible or midface. All ages and both sexes were included in this study. Patients should be free from any systemic disease that may affect normal healing of bone, and predictable outcome. Patients with good general condition allowing major surgical procedure under general anesthesia. Patients with physical and psychological tolerance. Exclusion Criteria: Patients with physical and psychological intolerance. Because psychological stress will affect the immune system and general health. Patients with systemic diseases like uncontrolled diabetes mellitus. Because uncontrolled diabetes mellitus has a negative impact on normal bone healing. Patients with old and/or mal-union fractures. As they will affect accuracy of reduction of the fractured segments. Patient with bad oral hygiene. As it has an influence on normal osseous healing
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Rofaida A Ahmad, MSc
Phone
+201099669299
Email
ro_fy_at@yahoo.com
First Name & Middle Initial & Last Name or Official Title & Degree
Rofaida A Ahmad, MSc
Phone
+201099669299
Email
rofaidaatef14@gmail.com
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Khaled Amr, PhD
Organizational Affiliation
Faculty of Oral and Dental Medicine -Cairo University
Official's Role
Study Director
Facility Information:
Facility Name
Faculty of Oral and Dental Medicine -Cairo University
City
Cairo
State/Province
Giza
ZIP/Postal Code
12613
Country
Egypt
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Rofaida A Ahmad, MSc
Phone
01099669299
Email
ro_fy_at@yahoo.com
First Name & Middle Initial & Last Name & Degree
Khaled Amr, PhD
Phone
01006029031
Email
khaledamr82@hotmail.com
First Name & Middle Initial & Last Name & Degree
Rofaida A Ahmad, MSc

12. IPD Sharing Statement

Plan to Share IPD
No
Links:
URL
http://www.ncbi.nlm.nih.gov/pubmed/17113444
Description
Open reduction and rigid internal fixation of mandibular condylar fractures by an intraoral approach: a long-term follow-up study of 15 patients
URL
https://www.ncbi.nlm.nih.gov/pubmed/?term=Accuracy+of+the+Computer-Aided+Surgical+Simulation+(CASS)+System+in+the+Treatment+of+Patients+With+Complex+Craniomaxillofacial+Deformity%3A+A+Pilot+Study.
Description
Accuracy of the Computer-Aided Surgical Simulation (CASS) System in the Treatment of Patients With Complex Craniomaxillofacial Deformity: A Pilot Study.
URL
http://link.springer.com/10.1007/s12663-012-0342-1
Description
A Comparative Evaluation of Fixation Techniques in Anterior Mandibular Fractures Using 2.0 mm Monocortical Titanium Miniplates Versus 2.4 mm Cortical Titanium Lag Screws
URL
https://www.ncbi.nlm.nih.gov/pubmed/26814516
Description
Titanium osteosynthesis hardware in maxillofacial trauma surgery: to remove or remain? A retrospective study.
URL
http://www.ncbi.nlm.nih.gov/pubmed/22075823
Description
Camerani, et al. Reconstruction of frontal bone using specific implant polyether-ether-ketone
URL
https://www.ncbi.nlm.nih.gov/pubmed/20465554
Description
The effect of diabetes mellitus on osseous healing.
URL
http://www.ncbi.nlm.nih.gov/pubmed/24501458
Description
Unfavourable outcomes in maxillofacial injuries: How to avoid and manage
URL
https://www.ncbi.nlm.nih.gov/pubmed/18040814
Description
Stress-induced immune dysregulation: Implications for wound healing, infectious disease and cancer

Learn more about this trial

Clinical Assessment of Computer-assisted PEEK Versus Conventional Titanium Plates on Mandibular Body Fractures

We'll reach out to this number within 24 hrs