Clinical Study to Evaluate Tear Characteristics Following Acute TrueTear™ Use
Primary Purpose
Dry Eye Syndromes
Status
Terminated
Phase
Not Applicable
Locations
United Kingdom
Study Type
Interventional
Intervention
TrueTear™ Application
Sponsored by
About this trial
This is an interventional treatment trial for Dry Eye Syndromes
Eligibility Criteria
Inclusion Criteria:
- Baseline Ocular Surface Disease Index© (OSDI©) score of at least 23 with no more than three responses of "not applicable"
- In at least one eye, a baseline Schirmer test of ≤ 10 mm/5 minutes AND a cotton swab nasal stimulation Schirmer test of at least 7 mm higher in the same eye
Exclusion Criteria:
- Chronic or recurrent epistaxis, coagulation disorders or other conditions that may increase the risk of bleeding
- History of nasal or sinus surgery
- Vascularized polyp, deviated septum or severe nasal airway obstruction at the Screening visit
- Intraocular and extraocular surgery in either eye within three months of the Screening Visit or refractive surgery within twelve months of the Screening Visit
- Cardiac demand pacemaker, implanted defibrillator, or other active implanted metallic or active implanted electronic device in the head
Sites / Locations
- Ocular Technology Group International
Arms of the Study
Arm 1
Arm 2
Arm Type
Experimental
Experimental
Arm Label
TrueTear™ Intranasal then Extranasal Application
TrueTear™ Extranasal then Intranasal Application
Arm Description
TrueTear™ device, intranasal (test) application, for approximately 3 minutes on Day 0 followed by TrueTear™ device, extranasal (control) application, for approximately 3 minutes on Day 14.
TrueTear™ device, extranasal (control) application, for approximately 3 minutes on Day 0 followed by TrueTear™ device, intranasal (test) application, for approximately 3 minutes on Day 14.
Outcomes
Primary Outcome Measures
Change From Baseline (Pre-application) in Tear Meniscus Height (TMH) at Eye Opening and Pre-Blink
Tear meniscus height is defined as the mean height of the lower tear prism to the edge of the eye lid measured by the investigator using the Tear scope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to time (T) T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 minutes (mins) after application was reported. A negative change from Baseline (Pre-application) indicates improvement.
Change From Baseline (Pre-application) in Tear Lipid Layer Thickness at Eye Opening and Pre-Blink
Lipid layer thickness is defined as the average thickness of the lipid layer calculated from the thickness of the various pattern weighted by the relative coverage of each pattern measured by the investigator using the Tearscope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported. A negative change from Baseline (Pre-application) indicates improvement .
Change From Baseline (Pre-application) in Non-Invasive Tear Film Break-Up Time (NIBUT)
Non-invasive break-up time is the time in seconds between eye opening and the appearance of the first visible break in the lipid layer of the pre-corneal tear film measured by the investigator using the Tearscope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported. A negative change from Baseline (Pre-application) indicates improvement.
Change From Pre-application in Protective Index (PI)
The Protected Index (PI) corresponds to the percentage of the corneal surface that is not exposed to the atmosphere (i.e. fully covered by the tear film) over the full interblink period measured by the investigator using a Tear scope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported.
Change From Pre-application in Exposed Area (EA)
Exposed Area is defined as the percentage of the observed area not covered by the tear film at the time of the blink hence exposed to the atmosphere measured by the investigator using a Tear scope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported.
Secondary Outcome Measures
Full Information
1. Study Identification
Unique Protocol Identification Number
NCT03274999
Brief Title
Clinical Study to Evaluate Tear Characteristics Following Acute TrueTear™ Use
Official Title
Randomized, Controlled, Single-Center, Cross-Over Clinical Study to Evaluate Tear Characteristics Following Acute TrueTear™ Use
Study Type
Interventional
2. Study Status
Record Verification Date
March 2021
Overall Recruitment Status
Terminated
Why Stopped
Based on interim review and decision to re-design the study.
Study Start Date
October 18, 2017 (Actual)
Primary Completion Date
November 9, 2017 (Actual)
Study Completion Date
November 9, 2017 (Actual)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Allergan
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
Yes
Product Manufactured in and Exported from the U.S.
Yes
5. Study Description
Brief Summary
This study will evaluate the change in tear meniscus height (TMH) produced by intranasal stimulation with TrueTear™ compared with the same device applied extranasally (control).
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Dry Eye Syndromes
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
10 (Actual)
8. Arms, Groups, and Interventions
Arm Title
TrueTear™ Intranasal then Extranasal Application
Arm Type
Experimental
Arm Description
TrueTear™ device, intranasal (test) application, for approximately 3 minutes on Day 0 followed by TrueTear™ device, extranasal (control) application, for approximately 3 minutes on Day 14.
Arm Title
TrueTear™ Extranasal then Intranasal Application
Arm Type
Experimental
Arm Description
TrueTear™ device, extranasal (control) application, for approximately 3 minutes on Day 0 followed by TrueTear™ device, intranasal (test) application, for approximately 3 minutes on Day 14.
Intervention Type
Device
Intervention Name(s)
TrueTear™ Application
Intervention Description
Intranasal and extranasal application of TrueTear™ device for approximately 3 minutes at Day 0 and Day 14.
Primary Outcome Measure Information:
Title
Change From Baseline (Pre-application) in Tear Meniscus Height (TMH) at Eye Opening and Pre-Blink
Description
Tear meniscus height is defined as the mean height of the lower tear prism to the edge of the eye lid measured by the investigator using the Tear scope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to time (T) T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 minutes (mins) after application was reported. A negative change from Baseline (Pre-application) indicates improvement.
Time Frame
Pre-application (Day 0) to time (T) 0 (immediately), 15, 30, 60, 120, 180, 240, 300 and 360 minutes on Day 0 after application
Title
Change From Baseline (Pre-application) in Tear Lipid Layer Thickness at Eye Opening and Pre-Blink
Description
Lipid layer thickness is defined as the average thickness of the lipid layer calculated from the thickness of the various pattern weighted by the relative coverage of each pattern measured by the investigator using the Tearscope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported. A negative change from Baseline (Pre-application) indicates improvement .
Time Frame
Pre-application (Day 0) to time (T) 0 (immediately), 15, 30, 60, 120, 180, 240, 300 and 360 minutes on Day 0 after application
Title
Change From Baseline (Pre-application) in Non-Invasive Tear Film Break-Up Time (NIBUT)
Description
Non-invasive break-up time is the time in seconds between eye opening and the appearance of the first visible break in the lipid layer of the pre-corneal tear film measured by the investigator using the Tearscope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported. A negative change from Baseline (Pre-application) indicates improvement.
Time Frame
Pre-application (Day 0) to time (T) 0 (immediately), 15, 30, 60, 120, 180, 240, 300 and 360 minutes on Day 0 after application
Title
Change From Pre-application in Protective Index (PI)
Description
The Protected Index (PI) corresponds to the percentage of the corneal surface that is not exposed to the atmosphere (i.e. fully covered by the tear film) over the full interblink period measured by the investigator using a Tear scope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported.
Time Frame
Pre-application (Day 0) to time (T) 0 (immediately), 15, 30, 60, 120, 180, 240, 300 and 360 minutes on Day 0 after application
Title
Change From Pre-application in Exposed Area (EA)
Description
Exposed Area is defined as the percentage of the observed area not covered by the tear film at the time of the blink hence exposed to the atmosphere measured by the investigator using a Tear scope Plus in conjunction with a Topcon SL-D7 slit lamp biomicroscope and high-resolution digital video recording. Change from Baseline to T0 (immediately), T15, T30, T60, T120, T180, T240, T300, T360 mins after application was reported.
Time Frame
Pre-application (Day 0) to time (T) 0 (immediately), 15, 30, 60, 120, 180, 240, 300 and 360 minutes on Day 0 after application
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Baseline Ocular Surface Disease Index© (OSDI©) score of at least 23 with no more than three responses of "not applicable"
In at least one eye, a baseline Schirmer test of ≤ 10 mm/5 minutes AND a cotton swab nasal stimulation Schirmer test of at least 7 mm higher in the same eye
Exclusion Criteria:
Chronic or recurrent epistaxis, coagulation disorders or other conditions that may increase the risk of bleeding
History of nasal or sinus surgery
Vascularized polyp, deviated septum or severe nasal airway obstruction at the Screening visit
Intraocular and extraocular surgery in either eye within three months of the Screening Visit or refractive surgery within twelve months of the Screening Visit
Cardiac demand pacemaker, implanted defibrillator, or other active implanted metallic or active implanted electronic device in the head
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Clinical Director
Organizational Affiliation
Allergan, plc
Official's Role
Study Director
Facility Information:
Facility Name
Ocular Technology Group International
City
London
ZIP/Postal Code
SW1E 6AU
Country
United Kingdom
12. IPD Sharing Statement
Links:
URL
http://AllerganClinicalTrials.com
Description
For information to locate a study location near you, please visit AllerganClinicalTrials.com
Learn more about this trial
Clinical Study to Evaluate Tear Characteristics Following Acute TrueTear™ Use
We'll reach out to this number within 24 hrs