search
Back to results

Clinical Trial on the Efficacy of Different Masks With and Without a Peripheral Sealing Device, Against Covid-19

Primary Purpose

Covid19, Personal Protective Equipment

Status
Completed
Phase
Not Applicable
Locations
Spain
Study Type
Interventional
Intervention
Peripheral sealing device for surgical mask or filtering face piece
IIR Surgical mask with Filtering face piece
Sponsored by
University of the Balearic Islands
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional health services research trial for Covid19

Eligibility Criteria

18 Years - 65 Years (Adult, Older Adult)All SexesAccepts Healthy Volunteers

Inclusion Criteria:

  • people familiar with the use of face masks, absence of allergy or intolerance to sodium saccharin or materials used, absence of relevant systemic diseases, age between 18-65 years, absence of obvious facial hair and signing the informed consent.

Exclusion Criteria:

  • people not familiar with the use of face masks, presence of allergy or intolerance to sodium saccharin or materials used, presence of relevant systemic diseases, presence of obvious facial hair and not signing the informed consent.

Sites / Locations

  • ADEMA University School

Arms of the Study

Arm 1

Arm 2

Arm 3

Arm 4

Arm 5

Arm Type

Experimental

Active Comparator

Experimental

Active Comparator

Experimental

Arm Label

Filtering face piece with peripheral sealing device

Filtering face piece without peripheral sealing device

IIR surgical mask with peripheral sealing device

IIR surgical mask without peripheral sealing device

Filtering face piece with IIR surgical mask

Arm Description

Individuals using the Filtering face Piece (FFP2) with the Peripheral Sealing Device (AMS).

Individuals using the Filtering face Piece (FFP2) without the AMS;

Individuals using the Surgical mask (SM) with the AMS;

Individuals using the Surgical mask (SM) without the AMS;

individuals using a FFP2 with a SM over it, simultaneously, without the AMS.

Outcomes

Primary Outcome Measures

Qualitative analysis of the respiratory protective equipment in protecting against the simulated aerosol: intergroup comparison
A qualitative analysis will be performed in order to evaluate whether the respiratory protective equipment is effective in protecting the individuals from a simulated aerosol environment. The individuals will be submitted to 7 different breathing exercises inside of a hood with their open mouth. A nebulizer filled with sacharin solution will be used to simulate an aerosol environment. If the individual do not sense the taste during the whole breathing exercises (total of 7 minutes) the respiratory protective equipment (RPE) used by this individual will be scored as "PASSED". If the individial sense the sweet taste during the 7 minutes, the RPE will be scored as "FAILED". The answer of the individuals using masks with the Peripheral Sealing Device and the controls (individual using masks without the peripheral sealing device) within each group will be compared. There is only one outcome measure: evaluate if the individuals are able to sense the aeresol or not.

Secondary Outcome Measures

Qualitative analysis of the respiratory protective equipment in protecting against the simulated aerosol: intragroup comparison
A qualitative analysis will be performed in order to evaluate whether the respiratory protective equipment (RPE) tested in the study are effective in protecting the individuals from a simulated aerosol environment. Subjects of the Subgroup FFP2 with AMS with the subjects of the Subgroup SM with AMS; the subjects of the Subgroup FFP2 with AMS with those of the subjects of the Group FFP2+SM and, finally, the subjects of the SM with AMS with the subjects of the FFP2+SM Group. There is only one outcome measure: evaluate if the individuals are able to sense the aeresol or not.

Full Information

First Posted
September 8, 2021
Last Updated
October 18, 2021
Sponsor
University of the Balearic Islands
search

1. Study Identification

Unique Protocol Identification Number
NCT05079308
Brief Title
Clinical Trial on the Efficacy of Different Masks With and Without a Peripheral Sealing Device, Against Covid-19
Official Title
Clinical Trial on the Level of Respiratory Protection of Surgical Face Masks and Filtering Face Pieces (FFP2), With and Without a Peripheral Sealing Device, Against Covid-19
Study Type
Interventional

2. Study Status

Record Verification Date
October 2021
Overall Recruitment Status
Completed
Study Start Date
March 1, 2021 (Actual)
Primary Completion Date
June 30, 2021 (Actual)
Study Completion Date
August 31, 2021 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University of the Balearic Islands

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No

5. Study Description

Brief Summary
A significant number of professionals subjected to high-risk situations have been infected by Covid-19, due to the lack of adequate respiratory protection equipment or poor marginal sealing adjustments. Then, the objective of this study is to determine if there are statistically significant differences in the level of respiratory protection of type IIR surgical face masks and filtering face masks, used with and without a peripheral sealing device, against the contagion of Covid-19 or other harmful biological agents. The proposed device is a thermoplastic resin ring composed of a reusable and biodegradable polylactic acid designed to be used in a healthcare environment. The individuals of the study will be submitted to qualitative fit tests, that meet current Ocupational Security and Health Administration (OSHA) standard. The mentioned qualitative fit test uses a sodium saccharin solution to evaluate the respiratory protection equipment in professionals in hospitals, emergency centers, and early childhood education centers.
Detailed Description
The purpose of the research is to determine if there are statistically significant differences in the level of respiratory protection in situations of high risk against the contagion of Covid-19 or other harmful biological agents, in subjects who use filtering face pieces (FFP2) with or without a peripheral sealing device (AMS), Type IIR surgical face masks with or without a AMS, and subjects using the FFP2 filtering face mask simultaneously with the Type IIR surgical face mask. For this, a total of 210 individuals were selected from different environments in order to attain diversity, while controlling for representativeness bias. They were selected from the ADEMA University School - UIB, nursing staff from the Infectious Diseases Service at Son Espases University Hospital, 112 Emergency Service of the Autonomous Community of the Balearic Islands and the General Directorate of Planning and Centers of the Ministry of Education and Professional Training (Balearic Islands, Spain). Participants were assigned to one of the 5 groups and subgroups, after accepting their participation in the study voluntarily and freely by signing the consent form approved by the CEI-IB. To evaluate the adjustment of the respiratory protective equipment with and without the personalized peripheral sealing device (AMS), a sweet sensitivity test was performed with the 3M FT-10 Qualitative Fit-Test Kit (Saint Paul, Minnesota, USA), which complies with the current standards of the Occupational Security and Health Administration (OSHA) and according to the protocol described in Riutord-Sbert et al. (2021). During the qualitative fit test, a total of seven mobility exercises of 60 seconds each were performed, and the nebulizer was squeezed, every 30 seconds: Phase 1 - Normal breathing Phase 2 - Slow and deep breathing Phase 3 - Breathing whilst moving the head to both sides Phase 4 - Breathing whilst moving the head up and down Phase 5 - Breathing spelling the alphabet Phase 6 - Breathing whilst moving up and down from the waist Phase 7 - Normal breathing If the fit test was completed within 7 minutes without the individual having detected the sweet taste, the seal was considered optimal or adequate and the experiment was graded as APPROVED. If the subject detected the sweet test before seven minutes, the adjustment was considered inadequate and was scored as FAILED, noting the time it took to detect the sweet taste as established in the protocol of the 3M FT-10 Fit test (Riutord-Sbert et al. 2021).

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Covid19, Personal Protective Equipment

7. Study Design

Primary Purpose
Health Services Research
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Participant
Allocation
Randomized
Enrollment
210 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Filtering face piece with peripheral sealing device
Arm Type
Experimental
Arm Description
Individuals using the Filtering face Piece (FFP2) with the Peripheral Sealing Device (AMS).
Arm Title
Filtering face piece without peripheral sealing device
Arm Type
Active Comparator
Arm Description
Individuals using the Filtering face Piece (FFP2) without the AMS;
Arm Title
IIR surgical mask with peripheral sealing device
Arm Type
Experimental
Arm Description
Individuals using the Surgical mask (SM) with the AMS;
Arm Title
IIR surgical mask without peripheral sealing device
Arm Type
Active Comparator
Arm Description
Individuals using the Surgical mask (SM) without the AMS;
Arm Title
Filtering face piece with IIR surgical mask
Arm Type
Experimental
Arm Description
individuals using a FFP2 with a SM over it, simultaneously, without the AMS.
Intervention Type
Device
Intervention Name(s)
Peripheral sealing device for surgical mask or filtering face piece
Intervention Description
The individuals used a Peripheral Sealing Device on a surgical mask or a filtering face piece mask and were submitted to a qualitative fit test, regulated by the Occupational Security and Health Administration (USA).
Intervention Type
Device
Intervention Name(s)
IIR Surgical mask with Filtering face piece
Intervention Description
The individuals used a IIR surgical mask with a filtering face piece mask and were submitted to a qualitative fit test, regulated by the Occupational Security and Health Administration (USA).
Primary Outcome Measure Information:
Title
Qualitative analysis of the respiratory protective equipment in protecting against the simulated aerosol: intergroup comparison
Description
A qualitative analysis will be performed in order to evaluate whether the respiratory protective equipment is effective in protecting the individuals from a simulated aerosol environment. The individuals will be submitted to 7 different breathing exercises inside of a hood with their open mouth. A nebulizer filled with sacharin solution will be used to simulate an aerosol environment. If the individual do not sense the taste during the whole breathing exercises (total of 7 minutes) the respiratory protective equipment (RPE) used by this individual will be scored as "PASSED". If the individial sense the sweet taste during the 7 minutes, the RPE will be scored as "FAILED". The answer of the individuals using masks with the Peripheral Sealing Device and the controls (individual using masks without the peripheral sealing device) within each group will be compared. There is only one outcome measure: evaluate if the individuals are able to sense the aeresol or not.
Time Frame
up to 5 months
Secondary Outcome Measure Information:
Title
Qualitative analysis of the respiratory protective equipment in protecting against the simulated aerosol: intragroup comparison
Description
A qualitative analysis will be performed in order to evaluate whether the respiratory protective equipment (RPE) tested in the study are effective in protecting the individuals from a simulated aerosol environment. Subjects of the Subgroup FFP2 with AMS with the subjects of the Subgroup SM with AMS; the subjects of the Subgroup FFP2 with AMS with those of the subjects of the Group FFP2+SM and, finally, the subjects of the SM with AMS with the subjects of the FFP2+SM Group. There is only one outcome measure: evaluate if the individuals are able to sense the aeresol or not.
Time Frame
up to 5 months

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
65 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria: people familiar with the use of face masks, absence of allergy or intolerance to sodium saccharin or materials used, absence of relevant systemic diseases, age between 18-65 years, absence of obvious facial hair and signing the informed consent. Exclusion Criteria: people not familiar with the use of face masks, presence of allergy or intolerance to sodium saccharin or materials used, presence of relevant systemic diseases, presence of obvious facial hair and not signing the informed consent.
Facility Information:
Facility Name
ADEMA University School
City
Palma De Mallorca
State/Province
Balearic Islands
ZIP/Postal Code
07009
Country
Spain

12. IPD Sharing Statement

Plan to Share IPD
No

Learn more about this trial

Clinical Trial on the Efficacy of Different Masks With and Without a Peripheral Sealing Device, Against Covid-19

We'll reach out to this number within 24 hrs