Closed Loop Ventilation With High Tidal Volumes and Safe Transpulmonary Pressure in COPD (COPD-SAFE) (COPD-SAFE)
Chronic Obstructive Pulmonary Disease
About this trial
This is an interventional supportive care trial for Chronic Obstructive Pulmonary Disease focused on measuring Mechanical ventilation, Adaptive Support Ventilation, Transpulmonary pressure, Intrinsic PEEP, Safety
Eligibility Criteria
Inclusion Criteria:
- Acute exacerbation of Chronic Obstructive Lung Disease
- Being intubated for less than 24 hours
- Not being planned to be extubated in 24 hours
- Expiratory time constant (RCexp) more than > 2.0 s
Exclusion Criteria:
- Restrictive lung pathologies
- Impaired hemodynamic status
- Esophageal pathologies
- Bronchopleural fistula
Sites / Locations
- Izmir Dr. Suat Seren Chest Diseases and Surgery Education and Research Hospital, Intensive Care Unit
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm 4
Experimental
Active Comparator
Experimental
Active Comparator
1.1. ASV, MV target 100%
1.2. Volume control, MV target %100
2.1. ASV, MV target to reach PaCO2< 45 mmHg
2.2. Volume control, MV target to reach PaCO2< 45 mmHg
Patients will be ventilated with ASV mode. Tidal volume, ventilation frequency, inspiratory duration will be automatically adjusted by the mechanical ventilator.
Patients will be ventilated with volume control mode. A tidal volume of 6-8 ml/kg will be used. I:E ratio will be set as 1:3 Ventilation frequency will be adjusted to reach the same volume target calculated in arm1.
Patients will be ventilated with ASV mode. Tidal volume, ventilation frequency, inspiratory duration will be automatically adjusted by the mechanical ventilator.
Patients will be ventilated with volume control mode. A tidal volume of 6-8 ml/kg will be used. I:E ratio will be set as 1:3. Ventilation frequency will be adjusted to reach the target PaCO2 level