Comparison of Precision in Brackets Position in Two Indirect Bonding Materials (IDBmaterials)
Primary Purpose
Orthodontic Appliance Complication, Malocclusion
Status
Not yet recruiting
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
Accuracy of indirect bonding of self-ligating brackets made with polyvinylsiloxane transfers
Accuracy of indirect bonding of self-ligating brackets made with thermal glue transfers
Sponsored by
About this trial
This is an interventional treatment trial for Orthodontic Appliance Complication focused on measuring indirect bonding
Eligibility Criteria
Inclusion Criteria:
- Permanent dentition with the presence of teeth 15-25 with
- Crowding in the upper arch according to Little's irregularity index,
- Teeth with healthy enamel (without hypoplasias, fluorosis, amelogenesis imperfecta),
- Fully erupted teeth
Exclusion Criteria:
- Absence of teeth selected for the study or that required premolar extractions before starting alignment and leveling
- Patients with rehabilitation such as crowns, veneers, fractured dentition, atypical morphology
- Teeth whose bracket loosens at the time of the procedure due to failure of the union
- Poor oral hygiene
- Patients with any significant displacement of the tooth that could prevent seating of the transfer tray
- Study models with bubbles.
Sites / Locations
Arms of the Study
Arm 1
Arm 2
Arm Type
Active Comparator
Active Comparator
Arm Label
Polyvinylsiloxane
Thermal glue
Arm Description
Accuracy of indirect bonding of self-ligating brackets made with polyvinylsiloxane transfers
Accuracy of indirect bonding of self-ligating brackets made with thermal glue transfers
Outcomes
Primary Outcome Measures
Linear mesio-distal position
It is the difference in the maximum Euclidean distance (two-dimensional plane) between a point mesial and distal of the bracket in the working model and in the patient's tooth.
Linear occlusal-gingival position
It is the difference in the maximum Euclidean distance (two-dimensional plane) between a point occlusal and gingival of the bracket in the working model and in the patient's tooth.
Secondary Outcome Measures
Full Information
NCT ID
NCT05483114
First Posted
July 29, 2022
Last Updated
July 29, 2022
Sponsor
Fundación Universitaria CIEO
1. Study Identification
Unique Protocol Identification Number
NCT05483114
Brief Title
Comparison of Precision in Brackets Position in Two Indirect Bonding Materials
Acronym
IDBmaterials
Official Title
Comparison of the Precision in the Position of Brackets With Two Indirect Bonding Materials: Polyvinylsiloxane and Thermal Glue. Split-mouth Randomized Clinical Trial.
Study Type
Interventional
2. Study Status
Record Verification Date
July 2022
Overall Recruitment Status
Not yet recruiting
Study Start Date
August 30, 2022 (Anticipated)
Primary Completion Date
August 30, 2022 (Anticipated)
Study Completion Date
November 29, 2022 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
Fundación Universitaria CIEO
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Product Manufactured in and Exported from the U.S.
No
Data Monitoring Committee
No
5. Study Description
Brief Summary
Objective: To compare the cementation precision of self-ligating brackets between two indirect bonding materials: polyvinylsiloxane and thermal glue.
Methods: Split-mouth randomized clinical trial study, with 15 participants. The study will be divided into two groups, Group 1: Polyvinylsiloxane and Group 2: Thermal glue.
Detailed Description
Patients from the self-ligation clinic who meet the inclusion criteria will be invited to participate and sign the informed consent. For the cementation of the brackets in each patient, the upper arch (right and left) will be divided from the second premolar on the right side to the second premolar on the left side, randomly assigned, to be cemented with a polyvinylsiloxane transfer tray and the other with thermal glue (materials selected for the study).
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Orthodontic Appliance Complication, Malocclusion
Keywords
indirect bonding
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Model Description
Split-mouth randomized clinical trial study, with 15 participants.
Masking
ParticipantCare ProviderOutcomes Assessor
Masking Description
A double-blind study will be carried out, where the patient and the operators who will record the results will be blinded. It is not possible to blind the clinician who performs the indirect bonding process. The processing of the registration of the linear measurements and the statistical advisor will be blinded, this will be done by means of codes for each group.
Allocation
Randomized
Enrollment
15 (Anticipated)
8. Arms, Groups, and Interventions
Arm Title
Polyvinylsiloxane
Arm Type
Active Comparator
Arm Description
Accuracy of indirect bonding of self-ligating brackets made with polyvinylsiloxane transfers
Arm Title
Thermal glue
Arm Type
Active Comparator
Arm Description
Accuracy of indirect bonding of self-ligating brackets made with thermal glue transfers
Intervention Type
Procedure
Intervention Name(s)
Accuracy of indirect bonding of self-ligating brackets made with polyvinylsiloxane transfers
Intervention Description
The uppethat consists of positioning brackets on a study model and they will be extended to the patient's mouth. .r hemiarch of each patient will be randomly placed to be cemented with a transfer tray made of polyvinylsiloxane thermal glue, by means of the indirect technique
Intervention Type
Procedure
Intervention Name(s)
Accuracy of indirect bonding of self-ligating brackets made with thermal glue transfers
Intervention Description
The uppethat consists of positioning brackets on a study model and they will be extended to the patient's mouth. .r hemiarch of each patient will be randomly placed to be cemented with a transfer tray made of polyvinylsiloxane thermal glue, by means of the indirect technique
Primary Outcome Measure Information:
Title
Linear mesio-distal position
Description
It is the difference in the maximum Euclidean distance (two-dimensional plane) between a point mesial and distal of the bracket in the working model and in the patient's tooth.
Time Frame
2 weeks
Title
Linear occlusal-gingival position
Description
It is the difference in the maximum Euclidean distance (two-dimensional plane) between a point occlusal and gingival of the bracket in the working model and in the patient's tooth.
Time Frame
2 weeks
10. Eligibility
Sex
All
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria:
Permanent dentition with the presence of teeth 15-25 with
Crowding in the upper arch according to Little's irregularity index,
Teeth with healthy enamel (without hypoplasias, fluorosis, amelogenesis imperfecta),
Fully erupted teeth
Exclusion Criteria:
Absence of teeth selected for the study or that required premolar extractions before starting alignment and leveling
Patients with rehabilitation such as crowns, veneers, fractured dentition, atypical morphology
Teeth whose bracket loosens at the time of the procedure due to failure of the union
Poor oral hygiene
Patients with any significant displacement of the tooth that could prevent seating of the transfer tray
Study models with bubbles.
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Maria M Zamora, DDS
Phone
3214391039
Email
mm.zamora@unicieo.edu.co
First Name & Middle Initial & Last Name or Official Title & Degree
Claudia Forero, DDS
Phone
3158991133
Email
cv.forero@unicieo.edu.co
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Maria M Zamora, DDS
Organizational Affiliation
Fundacion universitaria CIEO - Unicieo
Official's Role
Principal Investigator
12. IPD Sharing Statement
Plan to Share IPD
No
Learn more about this trial
Comparison of Precision in Brackets Position in Two Indirect Bonding Materials
We'll reach out to this number within 24 hrs