Continuous Glucose Monitoring for High-Risk Type 2 Diabetes in the Hospital (Cyber GEMS) (Cyber GEMS)
Type 2 Diabetes
About this trial
This is an interventional treatment trial for Type 2 Diabetes focused on measuring Type 2 Diabetes, Hospital, Continous Glucose Monitoring
Eligibility Criteria
Inclusion Criteria:
- Documented previous or current Type 2 Diabetes (T2D) diagnosis as defined by either diagnosis in the chart or an HbA1c > or = to 6.5% in the last 90 days
- Either on subcutaneous (SQ) insulin orders, or greater than two serum or Point of Care (POC) glucose > or = 200 mg/dL in most recent 24 hours of admission
Exclusion Criteria:
- Anticipated length of stay < 24 hours;
- Current or anticipated ICU placement;
- Does not speak English or Spanish;
- Known allergy to adhesives;
- Current participation in any medication or device research study;
- Pregnant;
- Any other condition that Multiple Principal Investigator (MPI) Philis-Tsimikas or the attending physician deems contraindicated
Sites / Locations
- Scripps Mercy HospitalRecruiting
Arms of the Study
Arm 1
Arm 2
Experimental
Active Comparator
Continuous Glucose Monitoring
Usual Care
Research Assistants (RAs) will verbally administer baseline survey and insert Dexcom G6 CGM, before unveiling the group assignment. CGM data will be transmitted from bedside iPhone to web-based platforms for: (1) Real-Time Management (via iPad-based FOLLOW app used by bedside RN and Digital Dashboard used by remote monitoring team) and (2) Clinical Optimization (via CLARITY, a Diabetes RN Coordinator will conduct remote clinical management of patients from a central, Scripps Diabetes Hub). A post-CGM satisfaction survey will be administered and compensation provided when CGM is removed prior to discharge or within 2 weeks following discharge. The CGM readings will be used to make recommendations for insulin adjustment and glucose management. After discharge, CGM data will be downloaded from a HIPPA-compliant, web-based CGM data management tool, and saved in Excel. The Data Analyst, blinded to condition, will routinely screen CGM data and merge individual spreadsheets for analysis.
RAs will verbally administer a baseline survey and insert the Dexcom G6 CGM. before unveiling the group assignment. CGM data will be blinded and used for evaluation purposes only. Glucose will be monitored via the hospital's standard POC testing protocol (i.e., prior to meals and at bedtime for patients who are eating, and every 4-6 waking hours if not eating). Glucose management in UC is designed to minimize differences between groups, aside from CGM monitoring, A post-CGM satisfaction survey will be administered and compensation provided when the CGM is removed prior to discharge or within 2 weeks following discharge. After discharge, CGM data will be downloaded from a HIPPA-compliant, web-based CGM data management tool, and saved in individual Excel spreadsheets. The study Data Analyst, blinded to study condition, will routinely screen CGM data and merge individual spreadsheets for analysis.