Conventional Surgery vs. Verion/VerifEye
Cataract, Astigmatism
About this trial
This is an interventional treatment trial for Cataract focused on measuring cataract, toric, phacoemulsification
Eligibility Criteria
Inclusion Criteria:
- Subject is undergoing bilateral cataract extraction or refractive lens exchange with intraocular lens implantation and astigmatism correction.
- Willing and able to provide written informed consent for participation in the study
- Willing and able to comply with scheduled visits and other study procedures.
Exclusion Criteria:
- Severe preoperative ocular pathology: amblyopia, rubella cataract, proliferative diabetic retinopathy, shallow anterior chamber, macular edema, retinal detachment, aniridia or iris atrophy, uveitis, history of iritis, iris neovascularization, medically uncontrolled glaucoma, microphthalmos or macrophthalmos, optic nerve atrophy, macular degeneration (with anticipated best postoperative visual acuity less than 20/30), advanced glaucomatous damage, etc.
- Uncontrolled diabetes.
- Use of any systemic or topical drug known to interfere with visual performance.
- Contact lens use during the active treatment portion of the trial.
- Any concurrent infectious/non infectious conjunctivitis, keratitis or uveitis.
- Pseudoexfoliation syndrome or any other condition that has the potential to weaken the zonules
- Previous refractive surgery.
- Any clinically significant, serious or severe medical or psychiatric condition that may increase the risk associated with study participation or study device implantation or may interfere with the interpretation of study results.
- Participation in (or current participation) any investigational drug or device trial within the previous 30 days prior to the start date of this trial.
- Intraocular conventional surgery within the past three months or intraocular laser surgery within one month in the operated eye.
Sites / Locations
- Carolina Eyecare Physicians, LLC
Arms of the Study
Arm 1
Arm 2
Active Comparator
Active Comparator
Conventional
Refractive Cataract Suite (Verion + ORA)
Surgeon's standard of care prior to getting VERION. Spherical power will be selected using the surgeon's preferred formula (Haigis, Holladay 2, Holladay, or other) and biometry method (IOL Master, Lenstar). Astigmatism correction will be planned using the surgeon's preferred keratometry method and calculator/nomogram to determine toric power and corneal incisions (i.e. Alcon toric calculator, Holladay toric calculator, Abbott Medical Optics (AMO) LRI calculator, etc). At time of surgery, axis of placement will be marked using blue ink marks. Corneal incisions will be made manually.
Digital Surgical Planning and Positioning Tools + ORA System with VerifEye or VerifEye +. Spherical power of the IOL will be selected using the Verion Planner with the surgeon's preferred formula with an optimized A-constant (Haigis, Holladay 2, Holladay, or other). Both toric lenses and corneal incisions will be calculated with the Verion Planner using the Verion Reference Unit keratometry and white to white measurements, and Lenstar biometry. The VERION Digital Markers L and M will be used for axis of placement and confirmed using ORA System with VerifEye or VerifEye +.