Dose Response Effects of Cervical Spinal Manipulative Therapy (SMT) on Pressure Sensitivity of Myofascial Trigger Points
Trigger Points, Myofascial, Myofascial Trigger Points, Myofascial Pain Syndrome
About this trial
This is an interventional treatment trial for Trigger Points, Myofascial focused on measuring myofascial pain syndrome, myofascial trigger points, spinal manipulative therapy, algometer, pressure pain thresholds
Eligibility Criteria
Inclusion Criteria:
- female subjects between the ages of 21-40 from the Canadian Memorial Chiropractic College (CMCC) main campus and campus clinic
- MTrPs in the infraspinatus muscle
Exclusion Criteria:
- Received cSMT within the 72 hour*
- Insufficient English language to complete pre-study questionnaires
- No MTrP in the infraspinatus muscle
- PPT in the MTrPs in the infraspinatus of greater than 35N
- Any absolute or relative contraindications to manipulation such as; previous VBI, blood-clotting disorders, hypertension, or cardiovascular disorders
- Any current or prior history of neurological signs and symptoms including facial or extremity weakness, abnormal sensation to the face, body, upper, or lower extremities, uncontrolled bodily movements, gait disturbances, unexplained dizziness, unexplained nausea or vomiting, difficulty with speaking or swallowing
- Previous history of a whiplash associated disorder
- Previous cervical spine surgery
- Any current or recent cervical or thoracic injury including cervical disc herniation with or without radiculopathy, facet irritation, fracture to the cervical spine, fracture to the thoracic spine, or fracture to the scapula
- Concomitant injuries and/or co-morbidities affecting the cervical, thoracic, upper limb musculoskeletal system and systemic diseases affecting the musculoskeletal system such as diabetes, muscular dystrophies, or chronic pain disorders
- Current nerve entrapments in the upper extremities
- Myositis ossificans in the infraspinatus muscle
- Seronegative spondyloarthropathies
- Current use of medications such as NSAIDS, antidepressants, or opioids *A wash out period of no cSMT is needed because people accommodate to treatment. A 72-hour time period was chosen as it allows sufficient time for any effects of cSMT on MTrPs to disappear
Sites / Locations
- Canadian Memorial Chiropractic College
Arms of the Study
Arm 1
Arm 2
Experimental
Sham Comparator
Two rcSMT group
One scSMT + One rcSMT Group
A rcSMT will be performed to the C5-C6 segment. A thrust maneuver will then be given to the C5-C6 segment. A rotational inferior drop thrust maneuver will be performed. Immediately after the first rcSMT the subject will turn over on the chiropractic table to lie in the prone position for a post-rcSMT PPT measurement with the same algometer performed by the research assistant. These will be taken at 5-minute intervals. A second rcSMT will be performed at 30 minutes after the first rcSMT. The invention protocol will be repeated. The subject will turn over to the prone position for repeat PPT measurements at 5-minute intervals post-rcSMT for 30 mins. Once the subject has left the treatment area the clinician will mark on the treatment card whether the rcSMT was performed with or without cavitation for quality control purposes.
A scSMT will be performed with the contact hand of the clinician resting lightly on the paraspinal area of the neck of the subject. The subject's head will be rotated to 45 degrees and supported by the clinician's forearm, lying on headpiece. A inferior drop thrust will be applied to the drop piece. After the first scSMT maneuver the subject will turn over on the chiropractic table to lie in the prone position for a post-scSMT PPT measurement. PPT measurements will be taken at 5-minute intervals for 30 minutes. A rcSMT will be performed 30 minutes after the first scSMT. The subject will turn over to the prone position for repeat PPT measurements in 5-minute intervals for 30 minutes post-rcSMT. Once the subject has left the treatment area the clinician will mark on the treatment card weather the scSMT was performed adequately without cavitation and whether a cavitation occurred with the rcSMT.