search
Back to results

e- Ab Sensor - Based Real-time Diagnosis of Enterovirus Type 71

Primary Purpose

EV71

Status
Unknown status
Phase
Not Applicable
Locations
Taiwan
Study Type
Interventional
Intervention
Electrosensing antibody probing system (e- Ab sensor)
Sponsored by
National Taiwan University Hospital
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for EV71 focused on measuring EV71

Eligibility Criteria

undefined - undefined (Child, Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • A: The patients with confirmed or suspected infection.
  • B: The patients without disease.

Exclusion Criteria:

  • Patients will be excluded if they couldn't sign the consent.

Sites / Locations

  • National Taiwan University HospitalRecruiting

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

virus detection

Arm Description

Outcomes

Primary Outcome Measures

The performance of e- Ab sensor
In comparison with results from direct sequencing of EV71, we evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction.

Secondary Outcome Measures

Full Information

First Posted
July 1, 2011
Last Updated
December 26, 2012
Sponsor
National Taiwan University Hospital
search

1. Study Identification

Unique Protocol Identification Number
NCT01388049
Brief Title
e- Ab Sensor - Based Real-time Diagnosis of Enterovirus Type 71
Official Title
e- Ab Sensor - Based Real-time Diagnosis of Enterovirus Type 71
Study Type
Interventional

2. Study Status

Record Verification Date
November 2011
Overall Recruitment Status
Unknown status
Study Start Date
July 2010 (undefined)
Primary Completion Date
July 2013 (Anticipated)
Study Completion Date
July 2013 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
National Taiwan University Hospital

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
To develop a real-time diagnostic technique with e- Ab sensor for Entervirus 71 detection, the investigators conduct a prospective clinical study. In comparison with results from direct sequencing of Entervirus 71, the investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction. The potential factors which may interfere with the results would be investigated. With such technique, the investigators hope to make early diagnosis and give EV71 patients early treatment to reduce the complications and case-fatality rate.
Detailed Description
Entervirus 71 is one of the most important infectious diseases in children and the important concern in public health. Since 1998, EV71 has become an endemic disease in Taiwan and caused hundreds of severe cases and dozens of fatal cases each year due to lack of EV71 vaccine. Family transmission study also showed that it is highly contagious among households as well as in daycares or kindergartens. Therefore, a rapid diagnosis is clinically necessary and can provide clinicians the rapid answers and make early treatment possible to reduce the complications and case-fatality rate. In addition, early diagnosis of the patients will alert parents and public health workers to prevent the contacts earlier and to limit the EV71 spread. Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins or viral antigen in medical samples, will be used for analyzing the interaction kinetics between Q.anti-EV71 and its antigen EV71 present in EV71 patients and normal sample. The system incorporates the use of engineered semiconductive antibodies or virus in vertical and lateral chip (eVchip) or lateral flow through (eVsignal) formats. In electrosensing virus probing, semiconductive antibodies are bound as a suitable electrosensing probe which specifically and selectively binds EV71 epitope target molecules in the test serum. In comparison with results from direct sequencing of EV71, the investigators evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction. The potential factors which may interfere with the results would be investigated. e- Ab sensor threshold decisions must maximize its sensitivity. Therefore, the threshold value in the test group is to find the decision could have 90% sensitivity and 90% specificity. With such technique, the investigators hope to make early diagnosis and give EV71 patients early treatment to reduce the complications and case-fatality rate.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
EV71
Keywords
EV71

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
InvestigatorOutcomes Assessor
Allocation
N/A
Enrollment
72 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
virus detection
Arm Type
Experimental
Intervention Type
Device
Intervention Name(s)
Electrosensing antibody probing system (e- Ab sensor)
Intervention Description
Electrosensing antibody probing system (e- Ab sensor), which was developed for the rapid and sensitive detection of hapten, proteins, or viral antigen in medical samples, will be used for analyzing the interaction kinetics between anti-EV71 antibody and its antigen (EV71) present in patients. The system incorporates the use of engineered semiconducive antibodies or virus in vertical and lateral chip (eAbchip) or lateral flow through (eAbsignal) formats. In electrosensing antibody probing, semiconductive antibodies are bound as a suitable electrosensing probe, which specifically and selectively binds targeted molecules (EV71) in the test specimens. From assessment of the electric signature of semiconductive anti-EV71 antibodies, the eABprobe could offer sensitive detection and precise quantification of EV71.
Primary Outcome Measure Information:
Title
The performance of e- Ab sensor
Description
In comparison with results from direct sequencing of EV71, we evaluate the performance of e- Ab sensor, including reproducibility, sensitivity, specificity, and cross-reaction.
Time Frame
1 Day

10. Eligibility

Sex
All
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: A: The patients with confirmed or suspected infection. B: The patients without disease. Exclusion Criteria: Patients will be excluded if they couldn't sign the consent.
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Shiming Lin, PhD
Phone
886-2-23123456
Ext
88458
Email
til@ntu.edu.tw
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Luan-Yin Chang, MD,PhD
Organizational Affiliation
National Taiwan University Hospital
Official's Role
Principal Investigator
Facility Information:
Facility Name
National Taiwan University Hospital
City
Taipei
ZIP/Postal Code
10051
Country
Taiwan
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Luan-Yin Chang, MD,PhD
Phone
886-2-2312-3456
Ext
71528
Email
lychang@ntu.edu.tw
First Name & Middle Initial & Last Name & Degree
Luan-Yin Chang, MD/PhD

12. IPD Sharing Statement

Learn more about this trial

e- Ab Sensor - Based Real-time Diagnosis of Enterovirus Type 71

We'll reach out to this number within 24 hrs