Effect of Nano-hydroxyapatite and LASER on Dentin Hypersensitivity
Dentin Sensitivity
About this trial
This is an interventional treatment trial for Dentin Sensitivity focused on measuring nano-hydroxyapatite, Laser, desensitizing
Eligibility Criteria
Inclusion criteria:
- The presence of at least one hypersensitive tooth;
Exclusion criteria:
- patients with systemic diseases;
- patients with pulpitis;
- patients with carious lesions;
- patients with defective restorations;
- patients with cleft enamel;
- patients with active periodontal disease;
- patients with analgesic medication;
- patients with pregnant or lactating women
- patients who have received professional desensitizing treatment in the last three months.
Sites / Locations
- Federal University of Pará
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm 4
Placebo Comparator
Experimental
Experimental
Experimental
GPLACEBO
Gn-HAP
GLASER
GLASERnHAP
In this group, a toothpaste without addition of fluoride or any other desensitizing agent (Natural, Contente®, Uberlândia, MG, Brazil) was applied to hypersensitive dentine. The GPLACEBO volunteers were submitted to the application of placebo dentifrice on the vestibular surfaces of hypersensitive teeth with the aid of a Microbrush applicator (Microbrush, 3M ESPE, São Paulo, Brazil) for 10 minutes. Then, a rubber cup (Unid Microdont, São Paulo, SP, Brazil) mounted on a low speed handpiece (Dabi Atlante, Ribeirão Preto, SO, Brazil) was used to scrub the desensitizing gel on teeth for 20 seconds on each tooth.
In this group a desensitizing gel containing 20% of nano-hydroxyapatite, 9000 ppm of sodium fluoride and 5% of potassium nitrate (Desensibilize Nano P, FGM®, Joinville, SC, Brazil) was applied to the hypersensitive dentin. The GnHAP volunteers will be submitted to the application of Desensibilize Nano P on the vestibular surfaces of hypersensitive teeth with the aid of a Microbrush applicator (Microbrush, 3M ESPE, São Paulo, Brazil) for 10 minutes. Then, a rubber cup (Unid Microdont, São Paulo, SP, Brazil) mounted on a low speed handpiece (Dabi Atlante, Ribeirão Preto, SO, Brazil) was used to scrub the desensitizing gel on teeth for 20 seconds in each tooth, according to the manufacturer's specifications.
In this group, the diode laser with an active medium of Asauxa bauxite (Photon Lase III, DMC Equipamentos Ltda; São Carlos, SP, Brazil) was applied in hypersensitive dentine. GLASER received the laser application using the infrared light spectrum with wavelength of 808 nm with its active AsGaAl medium in two points of the vestibular face of the hypersensitive teeth. It was applied at each point 60 J / cm², for 16 seconds. The laser was applied in 2 sessions with a time interval of 24 hours.
In this group the laser + nano-hydroxyapatite was applied. The laser was used with light intensity medium Asauxa (Photon Lase III, DMC Equipamentos Ltda, São Carlos, SP, Brazil) and a gel containing 20% nanohydroxyapatite, 9000 ppm sodium fluoride 5% potassium nitrate (Desensibilize Nano P, FGM®, Joinville, SC, Brazil) in hypersensitive dentin. GLASERnHAP first named a laser application and then an application of nanohydroxyapatite according to the manufacturer's recommendations.