Effect of Pressure on Skin Temperature When Using a Cryocompression Device
Primary Purpose
Temperature Change, Body
Status
Recruiting
Phase
Not Applicable
Locations
United Kingdom
Study Type
Interventional
Intervention
Cryocompression
Sponsored by
About this trial
This is an interventional treatment trial for Temperature Change, Body
Eligibility Criteria
Inclusion Criteria:
- >18 years of age.
Exclusion Criteria:
- BMI >40 kg/m2
- History of nerve damage or sensory deficit in the lower limbs (including frostbite)
- Hypersensitivity to cold, including hives
- Active inflammation or pain of the knee
- History of thrombosis, embolism, or other conditions related to impaired peripheral circulation
- Suffering from diagnosed diabetes, multiple sclerosis, rheumatoid arthritis, spinal cord injury, cardio-vascular disease, hypertension, Raynaud disease, cryoglobulinemia, or haemoglobinuria
- Confirmed or suspected tissue infection, an unstable fracture, a skin condition, or a tumour in the treatment area
- Cognitive impairment or communication barriers
Sites / Locations
- Physiology LaboratoryRecruiting
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm Type
Experimental
Experimental
Experimental
Arm Label
Low pressure
Medium pressure
High pressure
Arm Description
Participants will wear the cryocompression device for 30 minutes while ice-water at a temperature of 8℃ and a static pressure of 25 mmHg is applied to the lower limb by the cuff.
Participants will wear the cryocompression device for 30 minutes while ice-water at a temperature of 8℃ and an intermittent pressure of 25-50 mmHg is applied to the lower limb by the cuff.
Participants will wear the cryocompression device for 30 minutes while ice-water at a temperature of 8℃ and an intermittent pressure of 25-75 mmHg is applied to the lower limb by the cuff.
Outcomes
Primary Outcome Measures
Skin temperature
Skin temperature will be measured using a thermocouple positioned 20 mm distal to the patella. This sensor will be attached prior to the cryocompression device being applied, and will remain in place until the testing session is complete and skin temperature is >15℃. (The therapeutic skin temperature range for cryotherapy is thought to be 10-15℃). Temperature will be measured prior to the cryocompression device being applied; every 5 minutes during the test; and every 5 minutes after a test until the skin temperature reaches >15℃.
Secondary Outcome Measures
Full Information
NCT ID
NCT05454982
First Posted
July 7, 2022
Last Updated
August 17, 2022
Sponsor
University of Winchester
Collaborators
Physiolab Technologies Ltd
1. Study Identification
Unique Protocol Identification Number
NCT05454982
Brief Title
Effect of Pressure on Skin Temperature When Using a Cryocompression Device
Official Title
Effect of the Different Pressure Settings of a Continuous Cold-flow Cryocompression Device on Skin Temperature of the Knee: a Randomised Crossover Trial
Study Type
Interventional
2. Study Status
Record Verification Date
August 2022
Overall Recruitment Status
Recruiting
Study Start Date
July 11, 2022 (Actual)
Primary Completion Date
September 30, 2022 (Anticipated)
Study Completion Date
September 30, 2022 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University of Winchester
Collaborators
Physiolab Technologies Ltd
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No
5. Study Description
Brief Summary
Cryotherapy after surgery is widely utilised and has numerous practical applications for post-operative rehabili-tation. Previous research has suggested that during cold therapy, the skin temperature of the knee should be reduced to 10-15°C to maximise the therapeutic benefits of cooling while avoiding the risk of cold injuries such as nerve damage and frostbite (Wilke and Weiner, 2003; Bleakley, McDonough and MacAuley, 2004). The degree to which the pressure applied by a cuff to the knee has an effect on the achieved skin temperature of the treatment area is unknown.
The aim of this study is to determine the effect that different pressure settings have on skin temperature around the knee during a 30-minute cryocompression treatment.
Detailed Description
This prospective randomised crossover trial will recruit healthy adult volunteers from a university population to participate. To avoid the involvement of individuals with unequal relationships, participants will be recruited through the form of advertisements on staff and student noticeboards, and through an email invitation sent to students within the faculty that the study will take place. A power analysis demonstrated that a total of 30 participants would be required to achieve a power of 0.8 and alpha error probability of 0.05 for a small-medium effect size of f=0.2. Each participant will take part in each condition within the study in order to eliminate the risk of demographic factors confounding the results: Conditions will be conducted in a random order and will be named: A, B, and C. These conditions will involve the device being worn while ice-water is circulated through the knee sleeve at a maintained temperature of 8°C with a pressure of either 25 mmHg, 25-50mmHg, or 25-75 mmHg, respectively. Randomisation will be performed using a computer random number generator. Each testing session will take 45-60 minutes to complete, with at least 24 hours between tests with the same participant. In total, participants will be giving around 3 hours across 3 days to complete their participation.. Participants will not be compensated for taking part in the study, nor will they be charged.
All eligible participants will first be required to provide informed consent prior to their participation in the study. Once this has been obtained, participants will each attend a single testing session that should last no longer than 60 minutes. The height and mass of the participants will first be measured in order to calculate BMI, and participants' age and sex will be recorded to allow for later analysis to determine any confounding influence of these factors on the results.
Participants will be required to remain in a seated position with their leg in full extension and elevated, parallel to the floor, for the duration of each test session. The leg that will be used for the study will be randomly selected for each participant, and will remain the same for each condition. Skin temperature will be measured using a thermocouple, which will be attached with tape 20 mm distal to the patella. The Physiolab S1 cryocompression device will then be attached to the leg of the participant and the test will begin. Depending on the condition to which a participant has been assigned for a given test, the S1 will maintain the temperature of the water flowing through the device while applying one of three different pressures.
The temperature of the skin will be measured using a k-type thermocouple attached to an infrared thermometer immediately prior to the application of the S1 device, and then every 5 minutes for the duration of the test. The cuff will be worn for 30 minutes as per the manufacturer guidelines for cold therapy treatments. After 30 minutes, the cuff will be removed. If the temperature of the skin has been reduced to within 10-15℃, skin temperature will continue to be monitored every 5 minutes after the cuff has been removed until it rises above 15℃, at which point the test will end. This will allow for the total time to be measured that skin temperature re-mains within the target therapeutic range as a result of a single application of the cryocompression device. If the skin temperature is not reduced to within 10-15℃ while the cuff is worn, then the test will end after the cuff is removed at 30 minutes. Upon completion of the test, the temperature sensor will be removed from the leg of the participant; thus completing their participation in the test. Once each participant has taken part in all conditions, they will have completed their participation in the study.
The data will be analysed to detect any differences during testing compared to baseline measures, and between groups. All data will be first subjected to a Kolmogorov-Smirnov test to assess whether they are normally distributed. A repeated measures analysis of variance will be performed on all normally distributed data. A Friedman test will be performed on any data that are not normally distributed.
There is a low risk of cold injury to participants if their skin temperature reduces to <10℃. Skin temperature will be monitored every 5 minutes throughout the study and testing will be terminated if a participant's skin temperature dips below this threshold. Therefore, the risk to participants in this study is minimal.
Participants have the right to withdraw themselves and any collected data from the study at any time during and after their participation, without having to give a reason. They also have the right to terminate a test session at any time. Testing shall also be terminated as a result of any adverse reactions that emerge. Adverse reactions (e.g. pain) to the testing protocol are not expected due to the low-risk nature of the study, however any that occur shall be recorded and monitored until things return to baseline/normal. In order to monitor any pain/discomfort that might occur, a Visual Analogue Scale (0-10 scale) will be within sight of the participant at all times during testing: a test will be terminated if reported pain/discomfort exceeds 5/10, though none is expected. Any reported pain (or other adverse reactions) shall be stored along with the data collected for that participant. If a test is terminated for a reason that could be mitigated in future, participants will be offered the opportunity to repeat the test another day, should they wish to continue taking part in the study. If a test is terminated due to an adverse reaction that can not be mitigated in future, the participant (and any collected data) will be thanked for their time and withdrawn from the study.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Temperature Change, Body
7. Study Design
Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Crossover Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
30 (Anticipated)
8. Arms, Groups, and Interventions
Arm Title
Low pressure
Arm Type
Experimental
Arm Description
Participants will wear the cryocompression device for 30 minutes while ice-water at a temperature of 8℃ and a static pressure of 25 mmHg is applied to the lower limb by the cuff.
Arm Title
Medium pressure
Arm Type
Experimental
Arm Description
Participants will wear the cryocompression device for 30 minutes while ice-water at a temperature of 8℃ and an intermittent pressure of 25-50 mmHg is applied to the lower limb by the cuff.
Arm Title
High pressure
Arm Type
Experimental
Arm Description
Participants will wear the cryocompression device for 30 minutes while ice-water at a temperature of 8℃ and an intermittent pressure of 25-75 mmHg is applied to the lower limb by the cuff.
Intervention Type
Device
Intervention Name(s)
Cryocompression
Intervention Description
A cryocompression device will be attached to the lower limb of participants using a cuff spanning from the mid-thigh to mid-calf. The device will circulate ice-water at a constant temperature of 8℃ throughout each test session. Depending on the condition, the cuff will also apply varying levels of pressure for the duration of each test. Each test session will last for 30 minutes. Participants will take part in all conditions, with at least 24 hours rest in between test sessions. Skin temperature around the knee will be measured prior to the cryocompression device being applied; every 5 minutes during the 30 minute test; and every 5 minutes after the test until skin temperature >15℃.
Primary Outcome Measure Information:
Title
Skin temperature
Description
Skin temperature will be measured using a thermocouple positioned 20 mm distal to the patella. This sensor will be attached prior to the cryocompression device being applied, and will remain in place until the testing session is complete and skin temperature is >15℃. (The therapeutic skin temperature range for cryotherapy is thought to be 10-15℃). Temperature will be measured prior to the cryocompression device being applied; every 5 minutes during the test; and every 5 minutes after a test until the skin temperature reaches >15℃.
Time Frame
up to 14 days
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria:
>18 years of age.
Exclusion Criteria:
BMI >40 kg/m2
History of nerve damage or sensory deficit in the lower limbs (including frostbite)
Hypersensitivity to cold, including hives
Active inflammation or pain of the knee
History of thrombosis, embolism, or other conditions related to impaired peripheral circulation
Suffering from diagnosed diabetes, multiple sclerosis, rheumatoid arthritis, spinal cord injury, cardio-vascular disease, hypertension, Raynaud disease, cryoglobulinemia, or haemoglobinuria
Confirmed or suspected tissue infection, an unstable fracture, a skin condition, or a tumour in the treatment area
Cognitive impairment or communication barriers
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
James Faulkner, PhD
Phone
01962 624932
Email
james.faulkner@winchester.ac.uk
First Name & Middle Initial & Last Name or Official Title & Degree
James Belsey, PhD
Email
james.belsey@winchester.ac.uk
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
James Faulkner, PhD
Organizational Affiliation
University of Winchester
Official's Role
Principal Investigator
Facility Information:
Facility Name
Physiology Laboratory
City
Winchester
Country
United Kingdom
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
James Faulkner, PhD
Phone
01962 624932
Ext
4932
Email
james.faulkner@winchester.ac.uk
First Name & Middle Initial & Last Name & Degree
James Belsey, PhD
First Name & Middle Initial & Last Name & Degree
Eloise Paine, MSc
12. IPD Sharing Statement
Plan to Share IPD
No
IPD Sharing Plan Description
No individual data will be shared outside of the researchers directly involved in the data collection itself.
Citations:
PubMed Identifier
12776983
Citation
Wilke B, Weiner RD. Postoperative cryotherapy: risks versus benefits of continuous-flow cryotherapy units. Clin Podiatr Med Surg. 2003 Apr;20(2):307-22. doi: 10.1016/S0891-8422(03)00009-0.
Results Reference
background
PubMed Identifier
14754753
Citation
Bleakley C, McDonough S, MacAuley D. The use of ice in the treatment of acute soft-tissue injury: a systematic review of randomized controlled trials. Am J Sports Med. 2004 Jan-Feb;32(1):251-61. doi: 10.1177/0363546503260757.
Results Reference
background
PubMed Identifier
21332855
Citation
Fang L, Hung CH, Wu SL, Fang SH, Stocker J. The effects of cryotherapy in relieving postarthroscopy pain. J Clin Nurs. 2012 Mar;21(5-6):636-43. doi: 10.1111/j.1365-2702.2010.03531.x. Epub 2011 Feb 20.
Results Reference
background
PubMed Identifier
22928433
Citation
Waterman B, Walker JJ, Swaims C, Shortt M, Todd MS, Machen SM, Owens BD. The efficacy of combined cryotherapy and compression compared with cryotherapy alone following anterior cruciate ligament reconstruction. J Knee Surg. 2012 May;25(2):155-60. doi: 10.1055/s-0031-1299650.
Results Reference
background
Citation
Selfe J, Hardaker N, Whittaker J and Hayes C. An investigation into the effect on skin surface temperature of three cryotherapy modalities. Thermology International. 2009; 19(4): 121-126.
Results Reference
background
Learn more about this trial
Effect of Pressure on Skin Temperature When Using a Cryocompression Device
We'll reach out to this number within 24 hrs