Effect of Total Compression Time and Rate (Slope) on Incidence of Symptomatic ETD and MEB: A Phase II Prospective Study.
Eustachian Tube Dysfunction, Middle Ear Barotrauma, Middle Ear Disease
About this trial
This is an interventional prevention trial for Eustachian Tube Dysfunction focused on measuring Ear Pressure, Otic Barotrauma, Hyperbaric, Pressure Equalization, O'Neill Grading System, Compression Rate
Eligibility Criteria
Inclusion Criteria: Any patient meeting the indications for hyperbaric oxygen treatment.
-
Exclusion Criteria: Any patient with absolute contraindications to hyperbaric oxygen treatment, chronic bilateral perforation of the tympanic membrane or prior bilateral myringotomy tube placement.
-
Sites / Locations
- Phelps Hospital Northwell Health
Arms of the Study
Arm 1
Arm 2
Arm 3
Arm 4
Active Comparator
Active Comparator
Active Comparator
Active Comparator
Compression Profile 4
Compression Profile 3
Compression Profile 2
Compression Profile 1
Compression Profile/Schedule 4 = 10 minute linear, Total Time Interval of Compression to treatment depth = 10 minutes, Rate (slope) of compression = Linear rate of compression = 4.5 fsw/min to arrival at treatment depth 45 fsw
Compression Profile/Schedule 3 = 10 minute non-linear, Total Time Interval of Compression to treatment depth = 10 minutes Rate (slope) of compression = Non-Linear rate of compression = 3 fsw/min to a depth of 17 fsw, then 5 fsw/min up to a depth of 38.5 fsw, then 6.5 fsw/min to arrival at the treatment depth of 45 fsw
Compression Profile/Schedule 2 = 15 minute linear, Total Time Interval of Compression to treatment depth = 15 minutes Rate (slope) of compression = Linear rate of compression = 4.5 fsw/min to arrival at the treatment depth 45 fsw
Compression Profile/Schedule 1 = 15 minute non-linear, Total Time Interval of Compression to treatment depth = 15 minutes Rate (slope) of compression = Non-Linear rate of compression = 2 fsw/min to a depth of 13 fsw, then 3 fsw/min up to a depth of 35 fsw, then 5 fsw/min to arrival at the treatment depth of 45 fsw