search
Back to results

Efficacy and Safety of Clinical Telesurgery Using Chinese Independently Developed Surgical Robot System

Primary Purpose

Renal Cell Carcinoma, Bladder Cancer, Adrenal Tumor

Status
Completed
Phase
Not Applicable
Locations
China
Study Type
Interventional
Intervention
adrenalectomy for adrenal adenoma
Sponsored by
The Affiliated Hospital of Qingdao University
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Renal Cell Carcinoma

Eligibility Criteria

18 Years - 65 Years (Adult, Older Adult)All SexesAccepts Healthy Volunteers

Inclusion Criteria:

  • ASA class I-III
  • BMI: 18-30Kg/m2
  • adrenal tumors that need adrenalectomy (hormonally active or grow more than 1cm during annual evaluation; other benign adrenal tumors)
  • patients with Robson Stage I or II renal cell carcinoma that need radical nephrectomy
  • patients with Clinical Stage I or II bladder cancer that need radical cystectomy

Exclusion Criteria:

  • women during pregnancy or lactation period
  • patients with uncontrolled hypertension
  • patients with a history of epilepsy or psychosis
  • patients with severe cardiovascular disease (NYHA, grade III-IV)
  • patients with cerebrovascular disease (CVD)
  • patients with other diseases that cannot tolerate surgery

Sites / Locations

  • The Affiliated Hospital of Qingdao University

Arms of the Study

Arm 1

Arm Type

Experimental

Arm Label

Urologic tumor group

Arm Description

patients with adrenal adenoma, muscle-invasive bladder cancer or renal cell carcinoma are included in the experiment.

Outcomes

Primary Outcome Measures

success rate of the telesurgery
The success of the telesurgery is the robot-assisted telesurgery did not transfer to other types of surgery, such as open surgery or normal robot-assisted surgery. The number of the success divided by the total number is the success rate.

Secondary Outcome Measures

operative time
duration of each surgery
blood loss
blood loss of each surgery
latency time
Mechanical response delay of the robot, endoscope imaging and image processing delay plus video codec delay equals the total delay.

Full Information

First Posted
September 22, 2020
Last Updated
February 15, 2022
Sponsor
The Affiliated Hospital of Qingdao University
search

1. Study Identification

Unique Protocol Identification Number
NCT04570176
Brief Title
Efficacy and Safety of Clinical Telesurgery Using Chinese Independently Developed Surgical Robot System
Official Title
Clinical Trial Protocol of Primary Study on Efficacy and Safety of Telesurgery for Patients With Tumors of the Urinary System Using Chinese Independently Developed "MicroHand" Surgical Robot System
Study Type
Interventional

2. Study Status

Record Verification Date
September 2020
Overall Recruitment Status
Completed
Study Start Date
August 27, 2020 (Actual)
Primary Completion Date
September 22, 2020 (Actual)
Study Completion Date
November 30, 2021 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Principal Investigator
Name of the Sponsor
The Affiliated Hospital of Qingdao University

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No

5. Study Description

Brief Summary
One-arm clinical trial was adopted in this study. The surgeons performed remote urological surgery for patients through domestically produced "MicroHand" surgical robot system (Shandong Weigao Co., Ltd). The "MicroHand" surgical robot system consists of two physically separated subsystems named the "surgeon console" and "patient side cart". The surgeon console includes a stereo image viewer, two master manipulators, a control panel and several foot pedals. The patient side cart includes a passive arm that can slide in the up-down direction and be adjusted forward and backward, a swivel head that can rotate around the vertical axis, and three slave arms (one for the endoscopic camera and the other two for surgical instruments). The surgeon console (based in Qingdao) takes the surgeon's input and translates it into a control signal. After network transmission, the patient side cart (based in Anshun) translates the control signal into actual instrument manipulation. The 3D images captured by the endoscopic camera were simultaneously sent back to the screen of the surgeon console as visual feedback. Data between the surgeon console and the patient side cart were transmitted through a 5G network. The safety and effectiveness of the robotic system in remote clinical diagnosis and treatment were verified by the main judgment criterion and secondary judgment criterion. Six patients are planned to enroll in the clinical trial. Main judgment criterion: The robot-assisted telesurgery did not transfer to other types of surgery, such as open surgery or normal robot-assisted surgery. Secondary judgment criterion: operative time, blood loss, postoperative pain, preoperative adjusting time and hospitalization time. Patient enrollment: This trial aims to explore the safety and effectiveness of the domestically produced robotic system in remote clinical diagnosis and treatment through 5G network. Six patients are planned to enroll in the clinical trial, including 2 patients with adrenal tumor, 2 patients with bladder cancer and 2 patients with renal cell carcinoma.
Detailed Description
Objective: This clinical trial aims to evaluate the efficacy and safety of telesurgery for patients with tumors of the urinary system using Chinese independently developed "MicroHand" Surgical Robot System through 5G network. Content: One-arm clinical trial was adopted in this study. The product was domestically produced "MicroHand" surgical robot system (Shandong Weigao Co., Ltd). Before entering the clinical study, the patients were fully informed and the written informed consent were signed. According to the inclusion criteria and exclusion criteria, the researchers will conduct a detailed screening to determine whether they are suitable for the clinical study. Telesurgery would be conducted for patients who met the inclusion criteria using "MicroHand" surgical robot system. Data between the surgeon console and the patient side cart were transmitted through a 5G network. The safety and efficacy of the robotic system in remote clinical diagnosis and treatment were verified according to the main judgment criterion and secondary judgment criterion. Background: With the combination of robotic and network communication technology, telesurgery has become a reality. On the one hand, telesurgery can conserve and optimize medical resources, providing high-quality medical services to unbalanced areas, such as rural areas, stricken areas and battlefields. On the other hand, telesurgery can reduce the time spent by patients waiting for treatment and thus prevent diseases from worsening. The unbalanced distribution of medical resources has been a prominent problem in China. In addition, the vast territory and relatively lower medical distribution ratio per capita make it difficult for patients to receive timely and high-quality treatment, especially those in remote and underdeveloped areas. Therefore, telesurgery is more significant in China. In recent years, surgical robot systems and network communication technology have experienced breakthroughs. The operation systems of the Da Vinci robot in America, the REVO-I robot in South Korea and the ALF-X robot in Italy are more flexible and intelligent, performing well in surgical procedures. The "Micro Hand S" system robot, independently developed in China, represents a new generation of surgical robot systems. In addition to the flexible and intelligent characteristics of traditional robots, it has a series of advantages, such as a clear interface, light weight, low cost in terms of use and maintenance, and strong equipment compatibility. After preliminary experiments, it has been successfully applied in clinical surgery6. Meanwhile, in the field of network communication, the emerging 5G mobile communication technology (the 5th generation of wireless systems, 5G technology for short) is the latest generation of cellular mobile communication technology. It is also an extension of 4G (LTE-A or WiMax), 3G (UMTS or LTE) and 2G (GSM) technology. 5G technology has a high data rate, low latency, high throughput, equipment connection on a large scale, low cost and low energy consumption. The emergence of 5G technology offers more opportunities for the prevalence of telesurgery. In September 2019, our research group carried out the first 5G remote telesurgery using the "Micro Hand S" system robot and a 5G network between Qingdao, Shandong Province, and Xixiu, Guizhou Province, in September 2019 in China (the network communication distance was nearly 3000 km). Specifically, the investigators conducted four ultra-remote laparoscopic surgeries, including left nephrectomy, partial hepatectomy, cholecystectomy and cystectomy in a swine model under the 5G network using a domestically produced "Micro Hand S" surgical robot. the investigators accomplished four laparoscopic telesurgeries successfully, with an average network delay of 264 ms (including a round-trip transporting delay of 114 ms and a 1.20% data package loss ratio). Moreover, the total blood loss was 25 ml and no complications occurred during the procedures. The investigators demonstrated that ultra-remote laparoscopic telesurgery can be performed safely and smoothly under the 5G network using domestically produced equipment. On such basis, our research group planned to carry out this clinical trial to evaluate the efficacy and safety of telesurgery for patients with tumors of the urinary system using Chinese independently developed "MicroHand" Surgical Robot System through 5G network. Introduction of the "MicroHand" surgical robot: The "MicroHand" surgical robot system consists of two physically separated subsystems named the "surgeon console" and "patient side cart". The surgeon console includes a stereo image viewer, two master manipulators, a control panel and several foot pedals. The patient side cart includes a passive arm that can slide in the up-down direction and be adjusted forward and backward, a swivel head that can rotate around the vertical axis, and three slave arms (one for the endoscopic camera and the other two for surgical instruments). The surgeon console (based in Qingdao) takes the surgeon's input and translates it into a control signal. After network transmission, the patient side cart (based in Anshun) translates the control signal into actual instrument manipulation. The 3D images captured by the endoscopic camera were simultaneously sent back to the screen of the surgeon console as visual feedback. Steps of the procedure: ① The surgeon console was placed in Qingdao, Shangdong Province, while the patient side cart was placed in Anshun, Guizhou Province. ② Connections between the surgeon console and the patient side cart were established through a public 5G wireless network. Special 5G customer premise equipment (CPE) was used as a signal repeater station and amplifier. Upload and download speed will be tested as network bandwidth. ③ After general anesthesia, the supine position was maintained, the surgical area was disinfected, and pneumoperitoneum was established from the left side of the umbilicus by using a Veress needle. Then, trocars were inserted, and slave arms were delivered. Slave arm A was equipped with robotic grasp pliers, and Slave arm C was equipped with an ultrasonic scalpel (bipolar pliers or electrocautery). Robot-assisted telesurgeries, including adrenalectomy, cystectomy and nephrectomy, were performed by surgeons from the departments of urology. Surgeons in Qingdao performed the dissection and coagulation of the target organs, while assistants in Anshun performed exposure of structures and clip application. Trocar placement and position of the patients were also adjusted in each telesurgery by the assistants if necessary. After completion of the dissection, the target organs were removed by the assistant bedside. Then the pneumoperitoneum was exsufflated and the incisions were closed. Intraoperative network latencies and vital signs were monitored constantly. The master-slave manipulation consistency was assessed subjectively. The operative time, blood loss and complications were recorded.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Renal Cell Carcinoma, Bladder Cancer, Adrenal Tumor

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Single Group Assignment
Masking
None (Open Label)
Allocation
N/A
Enrollment
1 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Urologic tumor group
Arm Type
Experimental
Arm Description
patients with adrenal adenoma, muscle-invasive bladder cancer or renal cell carcinoma are included in the experiment.
Intervention Type
Procedure
Intervention Name(s)
adrenalectomy for adrenal adenoma
Other Intervention Name(s)
cystectomy for muscle-invasive bladder cancer, nephrectomy for patients with renal cell carcinoma.
Intervention Description
adrenalectomy, cystectomy and nephrectomy
Primary Outcome Measure Information:
Title
success rate of the telesurgery
Description
The success of the telesurgery is the robot-assisted telesurgery did not transfer to other types of surgery, such as open surgery or normal robot-assisted surgery. The number of the success divided by the total number is the success rate.
Time Frame
during the procedure
Secondary Outcome Measure Information:
Title
operative time
Description
duration of each surgery
Time Frame
during the procedure
Title
blood loss
Description
blood loss of each surgery
Time Frame
during the procedure
Title
latency time
Description
Mechanical response delay of the robot, endoscope imaging and image processing delay plus video codec delay equals the total delay.
Time Frame
during the procedure

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
65 Years
Accepts Healthy Volunteers
Accepts Healthy Volunteers
Eligibility Criteria
Inclusion Criteria: ASA class I-III BMI: 18-30Kg/m2 adrenal tumors that need adrenalectomy (hormonally active or grow more than 1cm during annual evaluation; other benign adrenal tumors) patients with Robson Stage I or II renal cell carcinoma that need radical nephrectomy patients with Clinical Stage I or II bladder cancer that need radical cystectomy Exclusion Criteria: women during pregnancy or lactation period patients with uncontrolled hypertension patients with a history of epilepsy or psychosis patients with severe cardiovascular disease (NYHA, grade III-IV) patients with cerebrovascular disease (CVD) patients with other diseases that cannot tolerate surgery
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Haitao Niu, PhD
Organizational Affiliation
The Affiliated Hospital of Qingdao University
Official's Role
Study Chair
Facility Information:
Facility Name
The Affiliated Hospital of Qingdao University
City
Qingdao
State/Province
Shandong
ZIP/Postal Code
266003
Country
China

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
18803341
Citation
Nguan C, Miller B, Patel R, Luke PP, Schlachta CM. Pre-clinical remote telesurgery trial of a da Vinci telesurgery prototype. Int J Med Robot. 2008 Dec;4(4):304-9. doi: 10.1002/rcs.210.
Results Reference
result
PubMed Identifier
18295861
Citation
Sterbis JR, Hanly EJ, Herman BC, Marohn MR, Broderick TJ, Shih SP, Harnett B, Doarn C, Schenkman NS. Transcontinental telesurgical nephrectomy using the da Vinci robot in a porcine model. Urology. 2008 May;71(5):971-3. doi: 10.1016/j.urology.2007.11.027. Epub 2008 Mar 4.
Results Reference
result
PubMed Identifier
12136861
Citation
Clayman RV. Transatlantic robot-assisted telesurgery. J Urol. 2002 Aug;168(2):873-4. No abstract available.
Results Reference
result
PubMed Identifier
11923603
Citation
Marescaux J, Leroy J, Rubino F, Smith M, Vix M, Simone M, Mutter D. Transcontinental robot-assisted remote telesurgery: feasibility and potential applications. Ann Surg. 2002 Apr;235(4):487-92. doi: 10.1097/00000658-200204000-00005.
Results Reference
result
PubMed Identifier
19222048
Citation
Garcia P, Rosen J, Kapoor C, Noakes M, Elbert G, Treat M, Ganous T, Hanson M, Manak J, Hasser C, Rohler D, Satava R. Trauma Pod: a semi-automated telerobotic surgical system. Int J Med Robot. 2009 Jun;5(2):136-46. doi: 10.1002/rcs.238.
Results Reference
result
PubMed Identifier
27649314
Citation
Lefranc M, Peltier J. Evaluation of the ROSA Spine robot for minimally invasive surgical procedures. Expert Rev Med Devices. 2016 Oct;13(10):899-906. doi: 10.1080/17434440.2016.1236680. Epub 2016 Sep 30.
Results Reference
result
PubMed Identifier
27123543
Citation
Abdel Raheem A, Troya IS, Kim DK, Kim SH, Won PD, Joon PS, Hyun GS, Rha KH. Robot-assisted Fallopian tube transection and anastomosis using the new REVO-I robotic surgical system: feasibility in a chronic porcine model. BJU Int. 2016 Oct;118(4):604-9. doi: 10.1111/bju.13517. Epub 2016 May 26.
Results Reference
result
PubMed Identifier
25840895
Citation
Fanfani F, Monterossi G, Fagotti A, Rossitto C, Gueli Alletti S, Costantini B, Gallotta V, Selvaggi L, Restaino S, Scambia G. The new robotic TELELAP ALF-X in gynecological surgery: single-center experience. Surg Endosc. 2016 Jan;30(1):215-21. doi: 10.1007/s00464-015-4187-9. Epub 2015 Apr 4.
Results Reference
result
PubMed Identifier
26433570
Citation
Moglia A, Ferrari V, Morelli L, Ferrari M, Mosca F, Cuschieri A. A Systematic Review of Virtual Reality Simulators for Robot-assisted Surgery. Eur Urol. 2016 Jun;69(6):1065-80. doi: 10.1016/j.eururo.2015.09.021. Epub 2015 Oct 1.
Results Reference
result
PubMed Identifier
27194259
Citation
Yi B, Wang G, Li J, Jiang J, Son Z, Su H, Zhu S, Wang S. Domestically produced Chinese minimally invasive surgical robot system "Micro Hand S" is applied to clinical surgery preliminarily in China. Surg Endosc. 2017 Jan;31(1):487-493. doi: 10.1007/s00464-016-4945-3. Epub 2016 May 18.
Results Reference
result
PubMed Identifier
26293795
Citation
Yi B, Wang G, Li J, Jiang J, Son Z, Su H, Zhu S. The first clinical use of domestically produced Chinese minimally invasive surgical robot system "Micro Hand S". Surg Endosc. 2016 Jun;30(6):2649-55. doi: 10.1007/s00464-015-4506-1. Epub 2015 Aug 21.
Results Reference
result

Learn more about this trial

Efficacy and Safety of Clinical Telesurgery Using Chinese Independently Developed Surgical Robot System

We'll reach out to this number within 24 hrs