search
Back to results

Endo-GIA Versus Endowrist Stapler in Intracorporeal Urinary Diversion in Robotic Assisted Radical Cystectomy (EGIAES)

Primary Purpose

Bladder Cancer

Status
Completed
Phase
Not Applicable
Locations
Denmark
Study Type
Interventional
Intervention
Endowrist
Endo-GIA
Sponsored by
Jørgen Bjerggaard Jensen
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Bladder Cancer focused on measuring Endo-GIA Stapler, Endowrist Stapler

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • > 18 years old
  • The ability to understand Danish orally and in writing
  • undergoing robotic assisted cystectomy with intracorporeal ileal conduit

Exclusion Criteria:

-

Sites / Locations

  • Aarhus University Hospital

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

Experimental

Arm Label

Endo-GIA

Endo-wrist

Arm Description

Outcomes

Primary Outcome Measures

Postoperative bowel function
Primary outcome will be postoperative bowel function where a better bowel recovery is anticipated in the experimental Endowrist arm whereas serious complications are expected to be non-inferior to the current standard.

Secondary Outcome Measures

Full Information

First Posted
December 21, 2017
Last Updated
May 30, 2023
Sponsor
Jørgen Bjerggaard Jensen
search

1. Study Identification

Unique Protocol Identification Number
NCT03385798
Brief Title
Endo-GIA Versus Endowrist Stapler in Intracorporeal Urinary Diversion in Robotic Assisted Radical Cystectomy
Acronym
EGIAES
Official Title
Endo-GIA Versus Endowrist Stapler in Intracorporeal Urinary Diversion in Robotic Assisted Radical Cystectomy
Study Type
Interventional

2. Study Status

Record Verification Date
May 2023
Overall Recruitment Status
Completed
Study Start Date
January 1, 2018 (Actual)
Primary Completion Date
January 1, 2020 (Actual)
Study Completion Date
January 1, 2023 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor-Investigator
Name of the Sponsor
Jørgen Bjerggaard Jensen

4. Oversight

Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No

5. Study Description

Brief Summary
The study is a randomized clinical trial (RCT) including patients undergoing robotic assisted cystectomy with intracorporeal ileal conduit at four large university hospitals in Denmark. If included, the patients will be randomized 1:1 to two study arms: 1) Standard arm with current procedure where intracorporeal bowel anastomosis is performed with the 60 mm EndoGIA stapler, or 2) Experimental arm where the bowel anastomosis will be performed totally robotic with the Endowrist Intuitive robotic stapler with 2 subsequent elongated 45 mm magazines for the side-to-side anastomosis. Primary outcome will be postoperative bowel function where a better bowel recovery is anticipated in the experimental Endowrist arm whereas serious complications are expected to be non-inferior to the current standard.
Detailed Description
Cystectomy with urinary diversion is the standard treatment of muscle invasive and high risk non-muscle invasive bladder cancer. During cystectomy, a urinary diversion is constructed from a bowel segment. Restoration of the intestinal continuity is therefore an obligate part of the procedure. In Denmark, approximately 400 radical cystectomies are performed yearly with the majority of procedures performed as a laparoscopic robot assisted procedure. This includes urinary diversion by means of intracorporeal procedure. During current standard intracorporeal urinary diversion, an Endo-GIA stapler is handled by the assisting surgeon and not by the main surgeon as the Endo-GIA stapler is not integrated into the robot. The traditional Endo-GIA anastomosis is made as a side-by-side anastomosis with two 60 mm magazines: one for the side-to-side anastomosis and one for closing the end. Any reduction in the lumen of the anastomosis will clinically affect post-operative bowel function. It is known that at all cystectomy patients have intestinal paralysis / lack of normal bowel function in the first days postoperatively. It is thus plausible that a wider anastomosis will be able to reduce the duration of this in favor of the patient's post-operative nutrition, postoperative length of stay and convalescence. A stapler integrated in the robot (Endowrist stapler from Intuitive) is available. This has several advantages: it is operated by the robotic surgeon and not by the assistant, it is more flexible, and faster mobility. These advantages provide the possibility of precisely removing a minimal intestinal segment by the final transverse stapling. The biggest disadvantage of the robot-operated Endowrist staple is that it is not available in a 60 mm version but only in 45 mm, thus giving only an anastomosis of approximately the same lumen as using a 60 mm Endo-GIA staple but not better. An opportunity to make a more spacious anastomosis would be to "prolong" the longitudinal stapling as to the side-to-side anastomosis between the intestinal segments. This requires precise and coordinated handling of bowel graspers and staplers to make a complete elimination of the risk of anastomosis leakage, which in this respect is an advantage of robot-operated staples with the Endowrist stapler rather than an assistant handled stapler with Endo-GIA. Both Endo-GIA and Endowrist stapler are approved for clinical use according to the procedures described.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Bladder Cancer
Keywords
Endo-GIA Stapler, Endowrist Stapler

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Model Description
Randomized clinical trial
Masking
None (Open Label)
Allocation
Randomized
Enrollment
90 (Actual)

8. Arms, Groups, and Interventions

Arm Title
Endo-GIA
Arm Type
Active Comparator
Arm Title
Endo-wrist
Arm Type
Experimental
Intervention Type
Procedure
Intervention Name(s)
Endowrist
Intervention Description
Anastomosis made by Endowrist
Intervention Type
Procedure
Intervention Name(s)
Endo-GIA
Intervention Description
Anastomosis made by Endo-GIA
Primary Outcome Measure Information:
Title
Postoperative bowel function
Description
Primary outcome will be postoperative bowel function where a better bowel recovery is anticipated in the experimental Endowrist arm whereas serious complications are expected to be non-inferior to the current standard.
Time Frame
90 days

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: > 18 years old The ability to understand Danish orally and in writing undergoing robotic assisted cystectomy with intracorporeal ileal conduit Exclusion Criteria: -
Facility Information:
Facility Name
Aarhus University Hospital
City
Aarhus
ZIP/Postal Code
8200
Country
Denmark

12. IPD Sharing Statement

Plan to Share IPD
No
Citations:
PubMed Identifier
21901690
Citation
Choy PY, Bissett IP, Docherty JG, Parry BR, Merrie A, Fitzgerald A. Stapled versus handsewn methods for ileocolic anastomoses. Cochrane Database Syst Rev. 2011 Sep 7;(9):CD004320. doi: 10.1002/14651858.CD004320.pub3.
Results Reference
background
PubMed Identifier
18609000
Citation
Korolija D. The current evidence on stapled versus hand-sewn anastomoses in the digestive tract. Minim Invasive Ther Allied Technol. 2008;17(3):151-4. doi: 10.1080/13645700802103423.
Results Reference
background
PubMed Identifier
23238497
Citation
Chen C. The art of bowel anastomosis. Scand J Surg. 2012;101(4):238-40. doi: 10.1177/145749691210100403.
Results Reference
background
PubMed Identifier
28009143
Citation
Dal Moro F, Haber GP, Wiklund P, Canda AE, Balbay MD, Stenzl A, Zattoni F, Palou J, Gill I, Catto JW. Robotic intracorporeal urinary diversion: practical review of current surgical techniques. Minerva Urol Nefrol. 2017 Feb;69(1):14-25. doi: 10.23736/S0393-2249.16.02780-6. Epub 2016 Aug 31.
Results Reference
background
PubMed Identifier
26341822
Citation
Russell KW, O'Holleran BP, Bowen ME, Mone MC, Scaife CL. The Barcelona Technique for Ileostomy Reversal. J Gastrointest Surg. 2015 Dec;19(12):2269-72. doi: 10.1007/s11605-015-2929-6. Epub 2015 Sep 4.
Results Reference
background
PubMed Identifier
21223476
Citation
Jensen JB, Pedersen KV, Olsen KO, Bisgaard UF, Jensen KM. Mini-laparotomy approach to radical cystectomy. BJU Int. 2011 Oct;108(7):1125-30. doi: 10.1111/j.1464-410X.2010.09958.x. Epub 2011 Jan 11.
Results Reference
background
PubMed Identifier
22236136
Citation
Ducrotte P, Causse C. The Bowel Function Index: a new validated scale for assessing opioid-induced constipation. Curr Med Res Opin. 2012 Mar;28(3):457-66. doi: 10.1185/03007995.2012.657301. Epub 2012 Feb 16.
Results Reference
background

Learn more about this trial

Endo-GIA Versus Endowrist Stapler in Intracorporeal Urinary Diversion in Robotic Assisted Radical Cystectomy

We'll reach out to this number within 24 hrs