search
Back to results

Enterprise Stent Implantation in the Treatment of Carotid Artery Stenosis With Ischemic Stroke

Primary Purpose

Carotid Artery Stenosis

Status
Completed
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
Enterprise stent implantation
Only aspirin medication
Sponsored by
Beijing Chao Yang Hospital
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Carotid Artery Stenosis

Eligibility Criteria

17 Years - 85 Years (Child, Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Atherosclerotic plague-caused carotid artery stenosis
  • Severe carotid artery stenosis (unilateral stenosis > 70%) diagnosed according to angiography
  • Age 18-75 years
  • Of either sex
  • Provision of informed consent regarding trial procedure

Exclusion Criteria:

  • Non-atherosclerotic intracranial artery stenosis
  • Severe cognitive or mental disorder
  • Severe cardiovascular, hepatic, renal, or blood system diseases
  • Pregnant or lactating
  • Hemorrhagic disease or unable to receive anticoagulation or antiplatelet aggregation treatment
  • Allergy to stent material
  • Unable to or declined to cooperate with follow-up examination
  • Unable to provide informed consent because of intellectual disability or language disorder

Sites / Locations

    Arms of the Study

    Arm 1

    Arm 2

    Arm Type

    Experimental

    Experimental

    Arm Label

    Enterprise stent implantation group

    Only aspirin medication group

    Arm Description

    Patients with atherosclerotic ischemic stroke will be randomly allocated to receive Enterprise stent implantation in combination with antiplatelet medication for carotid artery stenosis.

    Patients with atherosclerotic ischemic stroke will be randomly allocated to receive only antiplatelet medication for carotid artery stenosis.

    Outcomes

    Primary Outcome Measures

    National Institutes of Health Stroke Scale score
    Patient's neurologic deficits will be evaluated with the National Institutes of Health Stroke Scale (NIHSS) score 1 year after stent implantation or antiplatelet medication or antiplatelet medication only.

    Secondary Outcome Measures

    Changes of Barthel index
    To evaluate patient's activities of daily living
    Carotid stenosis rate
    Following digital subtraction angiography examination (Siemens), Seldinger-guided femoral artery cannulation will be performed. Selective angiography will be conducted to harvest bilateral carotid artery images from the anterior-posterior, oblique and lateral views. Carotid stenosis rate = (diameter of distal stenotic segment - diameter of narrowest segment)/diameter of distal stenotic segment × 100%.

    Full Information

    First Posted
    June 14, 2016
    Last Updated
    June 14, 2016
    Sponsor
    Beijing Chao Yang Hospital
    search

    1. Study Identification

    Unique Protocol Identification Number
    NCT02802072
    Brief Title
    Enterprise Stent Implantation in the Treatment of Carotid Artery Stenosis With Ischemic Stroke
    Official Title
    Long-term Effects of Enterprise Self-expanding Intracranial Stent Implantation in the Treatment of Carotid Artery Stenosis in Patients With Ischemic Stroke: Study Protocol for a Randomized Controlled Trial
    Study Type
    Interventional

    2. Study Status

    Record Verification Date
    June 2016
    Overall Recruitment Status
    Completed
    Study Start Date
    January 2013 (undefined)
    Primary Completion Date
    January 2014 (Actual)
    Study Completion Date
    December 2015 (Actual)

    3. Sponsor/Collaborators

    Responsible Party, by Official Title
    Principal Investigator
    Name of the Sponsor
    Beijing Chao Yang Hospital

    4. Oversight

    Data Monitoring Committee
    Yes

    5. Study Description

    Brief Summary
    To investigate the long-term effects of intracranial implantation of Enterprise stent system versus antiplatelet medication on neurologic deficits, daily living abilities, and carotid artery stenosis in patients with atherosclerotic ischemic stroke.
    Detailed Description
    Atherosclerosis is a chronic degenerative disease that can cause intracranial carotid artery stenosis, which is a leading cause of ischemic stroke. The currently used interventions for carotid artery stenosis in ischemic stroke include internal medication, carotid endarterectomy (CEA) and carotid angioplasty and stenting (CAS). Internal medication for carotid artery stenosis is mainly performed to reduce risk factors for cerebrovascular disease, including anti-platelet aggregation, anticoagulation, lowering blood lipid and blood pressure, controlling blood glucose and improving living habits. As for patients with mild carotid artery stenosis, internal medication is generally recommended. Carotid endarterectomy has been confirmed to be a gold standard for the treatment of carotid artery stenosis. However, it is also limited by some factors including sophisticated technique, great trauma, general anesthesia, severe stroke, 9% fatality rate, and 7.6% cranial nerve injury. In addition, carotid endarterectomy is not suitable for patients with high-position or tandem carotid artery stenosis or carotid artery stenosis complicated by contralateral carotid artery occlusion. In recent years, CAS has been increasingly used for the treatment of carotid artery stenosis in patients with ischemic stroke because of its minimally invasive procedure, rapid recovery process and wide indications. Enterprise stent system is a U.S. Food and Drug Administration (FDA)-approved closed loop recoverable self-expanding stent that has been confirmed to be highly effective in the treatment of intracranial aneurysm. Existing evidence on use of Enterprise stent system for intracranial artery stenosis in patients with ischemic stroke mainly focus on case series and case reports. There is a lack of randomized controlled trial evidence regarding long-term effects of Enterprise stent implantation for the treatment of carotid artery stenosis after ischemic stroke. The existing related reports are case series or case reports with the caveats like non-randomized, non-blinded design with small sample sizes. Therefore, in this study, the investigators designed a double-blind, randomized, drug control trial to investigate the efficacy of Enterprise stent implantation in the treatment of carotid artery stenosis in patients with ischemic stroke. Enterprise stent system is a novel closed loop self-expanding stent that is made of Ni-Ti alloy and shows favorable flexibility and ease in use, and its use was approved in 2009 in China. The current clinical evidence regarding use of Enterprise stent system mainly address on aneurismal treatment. In this study, the investigators will use Enterprise stent system to treat carotid artery stenosis in patients with ischemic stroke, which is of important clinical significance for secondary prevention of ischemic stroke. In addition, there is no long-term follow-up evidence regarding Enterprise stent implantation of carotid artery stenosis after ischemic stroke, so 3-year follow-up will be performed in this study. In this study, simple antiplatelet drug will be used as controls to investigate the superiority of Enterprise stent implantation in combination with antiplatelet over antiplatelet medication only in the treatment of carotid artery stenosis. Outcomes from this study will add objective, rigorous, double-blind, randomized, controlled long-term follow-up trial evidence to Enterprise stent implantation for the treatment of carotid artery stenosis after ischemic stroke. Adverse events Possible adverse events associated with Enterprise stent implantation include puncture site hematoma, vascular spasm, bradycardia, hypotension, cerebral hyperperfusion syndrome, device shifting, local ischemia, vascular occlusion, ischemic stroke, intraoperative hypertension, postoperative hypotension and hypoglycemia. If adverse events occur, details of the event including the date of occurrence, measures taken related to the treatment, causal relationship with the treatment and treatment of the adverse event will be reported to the principal investigator and the institutional review board within 24 hours. Data collection, management, analysis and open access All data will be collected in case report forms and collated. Collated data will be input into an electronic database using a double-data entry strategy by trained professional stall. Information accuracy will be checked when all included patients will be followed up. The collected data will be locked by a researcher in charge and will not be altered for later review. All data related to this trial will be preserved by Beijing Chao-yang Hospital, Capital Medical University, China. The electronic database will be fully known to a professional statistician for statistical analysis. Anonymized trial data will be published at http://www.figshare.com. Statistical analysis All data will be statistically analyzed by a statistician blinded to randomization using SPSS 17.0 software. The successive normally distributed variables will be expressed as the mean ± SD. The non-normally distributed variables will be expressed as median and quartile. Classification variables will be expressed as counts and the percentage. Two-sample t-test (normally distributed data) or Mann-Whitney U test (non-normally distributed data) will be used for comparison of NIHSS score and Barthel index between stent implantation and drug groups. Chi-square test or Fisher's exact test will be used for comparison of carotid stenosis rate between these two groups. A level of P < 0.05 will be accepted as statistically significant. Auditing Trial progression will be reported to the ethics committee of Beijing Chao-yang Hospital, Capital Medical University, China every 1 year and the trial's status will be updated in the registration database. Confidentiality Trial data include paper and electronic forms. Electronic data will be preserved in a dedicated password-protected computer and managed by a data management professional. Data reported on paper will be preserved in a secure, locked place for future viewing.

    6. Conditions and Keywords

    Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
    Carotid Artery Stenosis

    7. Study Design

    Primary Purpose
    Treatment
    Study Phase
    Not Applicable
    Interventional Study Model
    Parallel Assignment
    Masking
    ParticipantInvestigator
    Allocation
    Randomized
    Enrollment
    100 (Actual)

    8. Arms, Groups, and Interventions

    Arm Title
    Enterprise stent implantation group
    Arm Type
    Experimental
    Arm Description
    Patients with atherosclerotic ischemic stroke will be randomly allocated to receive Enterprise stent implantation in combination with antiplatelet medication for carotid artery stenosis.
    Arm Title
    Only aspirin medication group
    Arm Type
    Experimental
    Arm Description
    Patients with atherosclerotic ischemic stroke will be randomly allocated to receive only antiplatelet medication for carotid artery stenosis.
    Intervention Type
    Device
    Intervention Name(s)
    Enterprise stent implantation
    Other Intervention Name(s)
    Enterprise self-expanding stent system implantation
    Intervention Description
    Enterprise stent system (Johnson & Johnson (Shanghai) Medical Equipment Co.,Ltd., China) is a closed loop self-expanding stent system that is made of Ni-Ti alloy. It consists of a self-expanding stent and a delivery system.
    Intervention Type
    Drug
    Intervention Name(s)
    Only aspirin medication
    Other Intervention Name(s)
    Drug intervention
    Intervention Description
    Only aspirin medication will be conducted, initial dose is 300 mg/d, 200 mg/d 6 months later, and 100 mg/d 1 year later.
    Primary Outcome Measure Information:
    Title
    National Institutes of Health Stroke Scale score
    Description
    Patient's neurologic deficits will be evaluated with the National Institutes of Health Stroke Scale (NIHSS) score 1 year after stent implantation or antiplatelet medication or antiplatelet medication only.
    Time Frame
    1 year after treatment
    Secondary Outcome Measure Information:
    Title
    Changes of Barthel index
    Description
    To evaluate patient's activities of daily living
    Time Frame
    0.5, 1, 2, 3 years after treatment
    Title
    Carotid stenosis rate
    Description
    Following digital subtraction angiography examination (Siemens), Seldinger-guided femoral artery cannulation will be performed. Selective angiography will be conducted to harvest bilateral carotid artery images from the anterior-posterior, oblique and lateral views. Carotid stenosis rate = (diameter of distal stenotic segment - diameter of narrowest segment)/diameter of distal stenotic segment × 100%.
    Time Frame
    1 year after treatment

    10. Eligibility

    Sex
    All
    Minimum Age & Unit of Time
    17 Years
    Maximum Age & Unit of Time
    85 Years
    Accepts Healthy Volunteers
    No
    Eligibility Criteria
    Inclusion Criteria: Atherosclerotic plague-caused carotid artery stenosis Severe carotid artery stenosis (unilateral stenosis > 70%) diagnosed according to angiography Age 18-75 years Of either sex Provision of informed consent regarding trial procedure Exclusion Criteria: Non-atherosclerotic intracranial artery stenosis Severe cognitive or mental disorder Severe cardiovascular, hepatic, renal, or blood system diseases Pregnant or lactating Hemorrhagic disease or unable to receive anticoagulation or antiplatelet aggregation treatment Allergy to stent material Unable to or declined to cooperate with follow-up examination Unable to provide informed consent because of intellectual disability or language disorder
    Overall Study Officials:
    First Name & Middle Initial & Last Name & Degree
    Meng Ji, Ph.D.
    Organizational Affiliation
    Beijing Chao Yang Hospital, China
    Official's Role
    Principal Investigator

    12. IPD Sharing Statement

    Plan to Share IPD
    Undecided

    Learn more about this trial

    Enterprise Stent Implantation in the Treatment of Carotid Artery Stenosis With Ischemic Stroke

    We'll reach out to this number within 24 hrs