search
Back to results

Evaluate Safety And Effectiveness Of The Tivoli® DES and The Firebird2® DES For Treatment Coronary Revascularization

Primary Purpose

Ischemic Heart Disease, Myocardial Ischemia, Coronary Artery Lesions,Primary

Status
Unknown status
Phase
Not Applicable
Locations
China
Study Type
Interventional
Intervention
Tivoli® DES
Firebird2® DES
Sponsored by
Essen Technology (Beijing) Co., Ltd.
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Ischemic Heart Disease

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • • The patient must be ≥18 of age;

    • Symptomatic ischemic heart disease and/or objective evidence of myocardial ischemia including chronic stable coronary artery disease, or acute coronary syndrome including non-ST-elevation and ST-elevation myocardial infarction;
    • Acceptable candidate for CABG;
    • The patient is willing to comply with specified follow-up evaluations;4.Patients who agree to accept the follow-up visits.
    • Patients can understand the study objectives psychologically and linguistically and show the sufficient compliance to the study protocol. Patients present acceptance of the risks and benefits described in the informed consent form.

Angiographic Inclusion criteria:

  • At least one lesion with a diameter stenosis >70% or more suitable for coronary stent implantation in a vessel with a reference diameter ranging from 2.5 mm to 4.0 mm;
  • Patients with multi-lesion or multi-vessel coronary disease, must have successful treatment (<30% diameter stenosis visual estimate) of the first treated lesion prior to treatment of other lesions at the same brand of stent. Staged (planned) procedures must be performed within 30 days of the index procedure.

Exclusion Criteria:

  • General Exclusion Criteria

    • Pregnant or nursing patients and those who plan pregnancy in the period up to 1 year following index procedure.
    • Patient has a history of bleeding diathesis or coagulopathy or patients in whom anti-platelet and/or anticoagulant therapy is contraindicated or in which patient will not be able to comply with dual antiplatelet therapy for at least 1 year;
    • Patient has other medical illness (e.g., cancer, known malignancy, congestive heart failure, organ transplant recipient or candidate) or known history of substance abuse (alcohol, cocaine, heroin etc.) that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (i.e., less than 1 year);
    • Left ventricular function <40%;
    • Cardiogenic shock or hemodynamic compromise requiring pressors and/or inotropes or mechanical support;
    • Patient has a known hypersensitivity or contraindication to aspirin, heparin, clopidogrel/ticlopidine, stainless steel alloy, cobalt chromium, Rapamycinry , styrene-butylenes-styrene or poly-lactic acid (PLA) polymer, and/or contrast sensitivity that cannot be adequately pre-medicated;
    • Any significant medical condition which in the Investigator's opinion may interfere with the patient's optimal participation in the study;
    • Currently participating in another investigational drug or device study or patient in inclusion in another investigational drug or device study during follow-up.
    • Existing impairment in liver and kidney.
    • Extremely tortuous and/or calcification lesions.

Angiographic exclusion criteria:

• Two or more chronic total occlusions in the proximal half of the epicardial coronary artery which cannot be recannalized.

Sites / Locations

  • The General Hospital of Shenyang Military RegionRecruiting

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

Experimental

Arm Label

Firebird2® DES

Tivoli® DES

Arm Description

Device:Firebird2® DES The Firebird2® rapamycin-eluting stent (Firebird2® DES) is an open cell balloon expandable cobalt chromium stent coated with a biocompatible durable styrene-butylenes-styrene (SBS) polymer containing rapamycin at a dose of 9 micrograms per millimeter of stent length.

Device:Tivoli® DES The Tivoli® DES is an open cell balloon expandable cobalt chromium stent coated with a bio-gradable polymer (PLGA) containing rapamycin at a dose of 8 micrograms per millimeter of stent length.

Outcomes

Primary Outcome Measures

Ischemia-driven Target Lesion Failure (TLF) which is a composite of cardiac death, myocardial infarction (Q and non-Q wave) and target lesion revascularization (TLR) at 12 months post-procedure.

Secondary Outcome Measures

Full Information

First Posted
September 5, 2012
Last Updated
February 20, 2013
Sponsor
Essen Technology (Beijing) Co., Ltd.
search

1. Study Identification

Unique Protocol Identification Number
NCT01681381
Brief Title
Evaluate Safety And Effectiveness Of The Tivoli® DES and The Firebird2® DES For Treatment Coronary Revascularization
Official Title
A Prospective, Open Label, Randomized Study to Evaluate Safety And Effectiveness Of The Tivoli® Biodegradable Polymer Rapamycin-Eluting Stent and The FIREBIRD2® Rapamycin-Eluting Coronary CoCr Stent For Treatment Coronary Revascularization
Study Type
Interventional

2. Study Status

Record Verification Date
November 2012
Overall Recruitment Status
Unknown status
Study Start Date
September 2012 (undefined)
Primary Completion Date
September 2013 (Anticipated)
Study Completion Date
September 2018 (Anticipated)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Essen Technology (Beijing) Co., Ltd.

4. Oversight

Data Monitoring Committee
Yes

5. Study Description

Brief Summary
This is a prospective, multi-center, open label, randomized study to evaluate the efficacy and safety of The TIVOLI Biodegradable polymer Rapamycin-Eluting Stent comparing with The FIREBIRD2™ Rapamycin-eluting Stent (DES) for Treatment Coronary Revascularization.

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Ischemic Heart Disease, Myocardial Ischemia, Coronary Artery Lesions,Primary, Coronary Disease, Acute Coronary Syndrome, Furcation Lesion of Coronary Artery

7. Study Design

Primary Purpose
Treatment
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
2790 (Anticipated)

8. Arms, Groups, and Interventions

Arm Title
Firebird2® DES
Arm Type
Active Comparator
Arm Description
Device:Firebird2® DES The Firebird2® rapamycin-eluting stent (Firebird2® DES) is an open cell balloon expandable cobalt chromium stent coated with a biocompatible durable styrene-butylenes-styrene (SBS) polymer containing rapamycin at a dose of 9 micrograms per millimeter of stent length.
Arm Title
Tivoli® DES
Arm Type
Experimental
Arm Description
Device:Tivoli® DES The Tivoli® DES is an open cell balloon expandable cobalt chromium stent coated with a bio-gradable polymer (PLGA) containing rapamycin at a dose of 8 micrograms per millimeter of stent length.
Intervention Type
Device
Intervention Name(s)
Tivoli® DES
Intervention Description
Device:Tivoli® DES The Tivoli® DES drug eluting stent(Tivoli® DES) is an open cell balloon expandable cobalt chromium stent coated with a bio-gradable polymer (PLGA) containing rapamycin at a dose of 8 micrograms per millimeter of stent length. In vitro assays have shown that about 50% of the drug releasing in 1 week and approximately 80% releasing in 28 days. The polymer may be degraded in 3 to 6 months in human body. This stent is supplied pre-mounted on a delivery catheter and is available in the following sizes: lengths of 10、15、18、21、25、30、35 mm and diameters of 2.5、2.75、3.0、3.5、4.0 mm.
Intervention Type
Device
Intervention Name(s)
Firebird2® DES
Intervention Description
The Firebird2® rapamycin-eluting stent (Firebird2® DES) is an open cell balloon expandable cobalt chromium stent coated with a biocompatible durable styrene-butylenes-styrene (SBS) polymer containing rapamycin at a dose of 9 micrograms per millimeter of stent length. In vitro assays have shown that about 50% of the drug elutes in 1 week and approximately 90% elutes in 1 month. This stent is supplied pre-mounted on a delivery catheter and is available in the following sizes: lengths of 13, 18, 23, 29, 33 mm and diameters of 2.25, 2.5, 2.75, 3.0, 3.5, 4.0 mm.
Primary Outcome Measure Information:
Title
Ischemia-driven Target Lesion Failure (TLF) which is a composite of cardiac death, myocardial infarction (Q and non-Q wave) and target lesion revascularization (TLR) at 12 months post-procedure.
Time Frame
12 months

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: • The patient must be ≥18 of age; Symptomatic ischemic heart disease and/or objective evidence of myocardial ischemia including chronic stable coronary artery disease, or acute coronary syndrome including non-ST-elevation and ST-elevation myocardial infarction; Acceptable candidate for CABG; The patient is willing to comply with specified follow-up evaluations;4.Patients who agree to accept the follow-up visits. Patients can understand the study objectives psychologically and linguistically and show the sufficient compliance to the study protocol. Patients present acceptance of the risks and benefits described in the informed consent form. Angiographic Inclusion criteria: At least one lesion with a diameter stenosis >70% or more suitable for coronary stent implantation in a vessel with a reference diameter ranging from 2.5 mm to 4.0 mm; Patients with multi-lesion or multi-vessel coronary disease, must have successful treatment (<30% diameter stenosis visual estimate) of the first treated lesion prior to treatment of other lesions at the same brand of stent. Staged (planned) procedures must be performed within 30 days of the index procedure. Exclusion Criteria: General Exclusion Criteria Pregnant or nursing patients and those who plan pregnancy in the period up to 1 year following index procedure. Patient has a history of bleeding diathesis or coagulopathy or patients in whom anti-platelet and/or anticoagulant therapy is contraindicated or in which patient will not be able to comply with dual antiplatelet therapy for at least 1 year; Patient has other medical illness (e.g., cancer, known malignancy, congestive heart failure, organ transplant recipient or candidate) or known history of substance abuse (alcohol, cocaine, heroin etc.) that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (i.e., less than 1 year); Left ventricular function <40%; Cardiogenic shock or hemodynamic compromise requiring pressors and/or inotropes or mechanical support; Patient has a known hypersensitivity or contraindication to aspirin, heparin, clopidogrel/ticlopidine, stainless steel alloy, cobalt chromium, Rapamycinry , styrene-butylenes-styrene or poly-lactic acid (PLA) polymer, and/or contrast sensitivity that cannot be adequately pre-medicated; Any significant medical condition which in the Investigator's opinion may interfere with the patient's optimal participation in the study; Currently participating in another investigational drug or device study or patient in inclusion in another investigational drug or device study during follow-up. Existing impairment in liver and kidney. Extremely tortuous and/or calcification lesions. Angiographic exclusion criteria: • Two or more chronic total occlusions in the proximal half of the epicardial coronary artery which cannot be recannalized.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Han Yaling, Prof.
Organizational Affiliation
The General Hospital of Shenyang Military Region
Official's Role
Principal Investigator
Facility Information:
Facility Name
The General Hospital of Shenyang Military Region
City
Shenyang
State/Province
Liaoning
ZIP/Postal Code
86-110016
Country
China
Individual Site Status
Recruiting
Facility Contact:
First Name & Middle Initial & Last Name & Degree
Han Yaling, Prof.
Phone
(86-024) 28851120
Email
hanyaling@263.net
First Name & Middle Initial & Last Name & Degree
Han Yaling, Prof.

12. IPD Sharing Statement

Citations:
PubMed Identifier
26858080
Citation
Han Y, Xu B, Xu K, Guan C, Jing Q, Zheng Q, Li X, Zhao X, Wang H, Zhao X, Li X, Yu P, Zang H, Wang Z, Cao X, Zhang J, Pang W, Li J, Yang Y, Dangas GD. Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent: Randomized Substudy of the I-LOVE-IT 2 Trial. Circ Cardiovasc Interv. 2016 Feb;9(2):e003145. doi: 10.1161/CIRCINTERVENTIONS.115.003145.
Results Reference
derived
PubMed Identifier
25440887
Citation
Han Y, Xu B, Jing Q, Lu S, Yang L, Xu K, Li Y, Li J, Guan C, Kirtane AJ, Yang Y; I-LOVE-IT 2 Investigators. A randomized comparison of novel biodegradable polymer- and durable polymer-coated cobalt-chromium sirolimus-eluting stents. JACC Cardiovasc Interv. 2014 Dec;7(12):1352-60. doi: 10.1016/j.jcin.2014.09.001. Epub 2014 Nov 12.
Results Reference
derived

Learn more about this trial

Evaluate Safety And Effectiveness Of The Tivoli® DES and The Firebird2® DES For Treatment Coronary Revascularization

We'll reach out to this number within 24 hrs