Evaluation of Multiple Needle Use in EUS-FNA for Pancreatic Cancer (EMUNE-07)

Primary Purpose

Pancreatic Cancer

Status
Completed
Phase
Not Applicable
Locations
United States
Study Type
Interventional
Intervention
Single needle
Multiple needle
Sponsored by
University of Chicago
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Pancreatic Cancer focused on measuring Pancreatic Cancer, Endoscopic Ultrasonography, Fine-Needle Aspiration, Cytopathology

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • Suspicion of pancreatic mass due to previous exam/s (CT, MR, ERCP, US, …) that requires EUS-FNA in order to complete diagnosis
  • Age ≥ 18 y/o
  • Formal informed consent
  • No previous chemotherapy or radiotherapy
  • No previous pancreatic surgery

Exclusion Criteria:

  • Any patient unable to understand the procedure, nature of the current study, or sign a consent form.

Sites / Locations

  • University of Chicago Medical Center

Arms of the Study

Arm 1

Arm 2

Arm Type

Active Comparator

Experimental

Arm Label

A

B

Arm Description

Patients assigned to simple needle group (SN) will be sampled for a total of 6 consecutive FNA passes with a single EUS-FNA needle (only replaced if the needle has a reduced performance). After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis.

Patients assigned to multiple needle group (MN) will be sampled for a total of 6 consecutive FNA passes, replacing the needle after every 2 passes. After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis.

Outcomes

Primary Outcome Measures

Evaluate if the early change of needle during EUS-FNA for suspected pancreatic cancer can reduce the number of passes needed to obtain a preliminary cytological diagnosis of neoplasia.

Secondary Outcome Measures

Rate of complications related with EUS-FNA
Influence of different factors in obtaining a positive cytological result

Full Information

First Posted
October 22, 2007
Last Updated
December 18, 2015
Sponsor
University of Chicago
Collaborators
Cook Group Incorporated
search

1. Study Identification

Unique Protocol Identification Number
NCT00548626
Brief Title
Evaluation of Multiple Needle Use in EUS-FNA for Pancreatic Cancer
Acronym
EMUNE-07
Official Title
EMUNE-07 Evaluation of Multiple Needle Use in EUS-FNA for Pancreatic Cancer
Study Type
Interventional

2. Study Status

Record Verification Date
December 2015
Overall Recruitment Status
Completed
Study Start Date
October 2007 (undefined)
Primary Completion Date
November 2015 (Actual)
Study Completion Date
November 2015 (Actual)

3. Sponsor/Collaborators

Responsible Party, by Official Title
Sponsor
Name of the Sponsor
University of Chicago
Collaborators
Cook Group Incorporated

4. Oversight

Data Monitoring Committee
No

5. Study Description

Brief Summary
The aim of this study is to evaluate if the early change of needle during EUS-FNA for suspected pancreatic cancer allows an earlier preliminary cytological diagnosis of neoplasia.
Detailed Description
This is a prospective randomized controlled trial which will recruit patients referred for suspicion of pancreatic mass and indication of EUS-FNA as part of standard of care in the Interventional Endoscopy Unit at the University Of Chicago Medical Center. Basic demographic data will be recorded for each patient. If a pancreatic mass is confirmed in EUS evaluation the patient will be randomized in a 1:1 ratio to either Control group (Single needle) or Investigational group (Multiple Needle). There will be an expert cytopathologist in the exploration room (blinded to the group assignment). Samples obtained through FNA will be prepared onsite either for cytological evaluation by the cytopathologist: each fine needle sample will be expressed by using a 10mL air-filled syringe onto a separate glass slide, and a direct smear will be made by an on-site cytopathologist. Each slide will be air-dried and/or alcohol fixed (95% ethanol), and direct smears will be prepared for immediate interpretation by staining with Diff-quick staining system. Patients assigned to simple needle group (SN) will be sampled for a total of 6 consecutive FNA passes with a single EUS-FNA needle (only replaced if the needle has a reduced performance). After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis. Patients assigned to multiple needle group (MN) will be sampled for a total of 6 consecutive FNA passes, replacing the needle after every 2 passes. After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis. A cytopathologist (#1) will be present during each EUS-FNA procedure to prepare the slides and determine whether each specimen was adequately cellular. After the procedure, all the cytological samples will be sent to the Pathology department in order to complete the study. A cytopathologist (#2) not present during the procedure will study all the sampling specimens obtained during the EUS-FNA procedure and produce the final and definitive cytopathological diagnosis. Criteria for pancreatic cancer and benign pancreatic lesions will be defined. Follow-up of all patients to assess early and late complications will be carried out for 30 days after the procedure. Endpoints: Primary endpoint: Evaluate if the early change of needle during EUS-FNA for suspected pancreatic cancer can reduce the number of passes needed to obtain a preliminary cytological diagnosis of neoplasia. We hypothesized that the number of passes needed using the multiple needles will be significantly less than that using the single needle. Secondary endpoints: Rate of complications related with EUS-FNA Influence of different factors in obtaining a positive cytological result (histological differentiation)

6. Conditions and Keywords

Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Pancreatic Cancer
Keywords
Pancreatic Cancer, Endoscopic Ultrasonography, Fine-Needle Aspiration, Cytopathology

7. Study Design

Primary Purpose
Diagnostic
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
Participant
Allocation
Randomized
Enrollment
47 (Actual)

8. Arms, Groups, and Interventions

Arm Title
A
Arm Type
Active Comparator
Arm Description
Patients assigned to simple needle group (SN) will be sampled for a total of 6 consecutive FNA passes with a single EUS-FNA needle (only replaced if the needle has a reduced performance). After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis.
Arm Title
B
Arm Type
Experimental
Arm Description
Patients assigned to multiple needle group (MN) will be sampled for a total of 6 consecutive FNA passes, replacing the needle after every 2 passes. After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis.
Intervention Type
Procedure
Intervention Name(s)
Single needle
Intervention Description
Patients will be sampled for a total of 6 consecutive FNA passes with a single EUS-FNA needle (only replaced if the needle has a reduced performance). After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis.
Intervention Type
Procedure
Intervention Name(s)
Multiple needle
Intervention Description
Patients will be sampled for a total of 6 consecutive FNA passes, replacing the needle after every 2 passes. After completing the 6th pass the endoscopist will be informed by the onsite cytopathologist about the preliminary cytological diagnosis.
Primary Outcome Measure Information:
Title
Evaluate if the early change of needle during EUS-FNA for suspected pancreatic cancer can reduce the number of passes needed to obtain a preliminary cytological diagnosis of neoplasia.
Time Frame
October 2007- September 2008
Secondary Outcome Measure Information:
Title
Rate of complications related with EUS-FNA
Time Frame
October 2007- September 2008
Title
Influence of different factors in obtaining a positive cytological result
Time Frame
October 2007- September 2008

10. Eligibility

Sex
All
Minimum Age & Unit of Time
18 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria: Suspicion of pancreatic mass due to previous exam/s (CT, MR, ERCP, US, …) that requires EUS-FNA in order to complete diagnosis Age ≥ 18 y/o Formal informed consent No previous chemotherapy or radiotherapy No previous pancreatic surgery Exclusion Criteria: Any patient unable to understand the procedure, nature of the current study, or sign a consent form.
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Irving Waxman, MD
Organizational Affiliation
Department of Medicine, University of Chicago Medical Center
Official's Role
Principal Investigator
Facility Information:
Facility Name
University of Chicago Medical Center
City
Chicago
State/Province
Illinois
ZIP/Postal Code
60637
Country
United States

12. IPD Sharing Statement

Citations:
PubMed Identifier
15044881
Citation
LeBlanc JK, Ciaccia D, Al-Assi MT, McGrath K, Imperiale T, Tao LC, Vallery S, DeWitt J, Sherman S, Collins E. Optimal number of EUS-guided fine needle passes needed to obtain a correct diagnosis. Gastrointest Endosc. 2004 Apr;59(4):475-81. doi: 10.1016/s0016-5107(03)02863-3.
Results Reference
background
PubMed Identifier
11577304
Citation
Wallace MB, Kennedy T, Durkalski V, Eloubeidi MA, Etamad R, Matsuda K, Lewin D, Van Velse A, Hennesey W, Hawes RH, Hoffman BJ. Randomized controlled trial of EUS-guided fine needle aspiration techniques for the detection of malignant lymphadenopathy. Gastrointest Endosc. 2001 Oct;54(4):441-7. doi: 10.1067/mge.2001.117764.
Results Reference
background
PubMed Identifier
16564863
Citation
Eloubeidi MA, Tamhane A, Varadarajulu S, Wilcox CM. Frequency of major complications after EUS-guided FNA of solid pancreatic masses: a prospective evaluation. Gastrointest Endosc. 2006 Apr;63(4):622-9. doi: 10.1016/j.gie.2005.05.024.
Results Reference
background
PubMed Identifier
15332028
Citation
Eloubeidi MA, Gress FG, Savides TJ, Wiersema MJ, Kochman ML, Ahmad NA, Ginsberg GG, Erickson RA, Dewitt J, Van Dam J, Nickl NJ, Levy MJ, Clain JE, Chak A, Sivak MV Jr, Wong R, Isenberg G, Scheiman JM, Bounds B, Kimmey MB, Saunders MD, Chang KJ, Sharma A, Nguyen P, Lee JG, Edmundowicz SA, Early D, Azar R, Etemad B, Chen YK, Waxman I, Shami V, Catalano MF, Wilcox CM. Acute pancreatitis after EUS-guided FNA of solid pancreatic masses: a pooled analysis from EUS centers in the United States. Gastrointest Endosc. 2004 Sep;60(3):385-9. doi: 10.1016/s0016-5107(04)01714-6.
Results Reference
background
PubMed Identifier
12094855
Citation
Harewood GC, Wiersema MJ. Endosonography-guided fine needle aspiration biopsy in the evaluation of pancreatic masses. Am J Gastroenterol. 2002 Jun;97(6):1386-91. doi: 10.1111/j.1572-0241.2002.05777.x.
Results Reference
background
PubMed Identifier
14579295
Citation
Eloubeidi MA, Jhala D, Chhieng DC, Chen VK, Eltoum I, Vickers S, Mel Wilcox C, Jhala N. Yield of endoscopic ultrasound-guided fine-needle aspiration biopsy in patients with suspected pancreatic carcinoma. Cancer. 2003 Oct 25;99(5):285-92. doi: 10.1002/cncr.11643.
Results Reference
background
PubMed Identifier
11275888
Citation
O'Toole D, Palazzo L, Arotcarena R, Dancour A, Aubert A, Hammel P, Amaris J, Ruszniewski P. Assessment of complications of EUS-guided fine-needle aspiration. Gastrointest Endosc. 2001 Apr;53(4):470-4. doi: 10.1067/mge.2001.112839.
Results Reference
background
PubMed Identifier
9097990
Citation
Wiersema MJ, Vilmann P, Giovannini M, Chang KJ, Wiersema LM. Endosonography-guided fine-needle aspiration biopsy: diagnostic accuracy and complication assessment. Gastroenterology. 1997 Apr;112(4):1087-95. doi: 10.1016/s0016-5085(97)70164-1.
Results Reference
background
PubMed Identifier
8635074
Citation
Niederhuber JE, Brennan MF, Menck HR. The National Cancer Data Base report on pancreatic cancer. Cancer. 1995 Nov 1;76(9):1671-7. doi: 10.1002/1097-0142(19951101)76:93.0.co;2-r.
Results Reference
background
PubMed Identifier
9512275
Citation
Binmoeller KF, Thul R, Rathod V, Henke P, Brand B, Jabusch HC, Soehendra N. Endoscopic ultrasound-guided, 18-gauge, fine needle aspiration biopsy of the pancreas using a 2.8 mm channel convex array echoendoscope. Gastrointest Endosc. 1998 Feb;47(2):121-7. doi: 10.1016/s0016-5107(98)70343-8.
Results Reference
background
PubMed Identifier
2070995
Citation
Cotton PB, Lehman G, Vennes J, Geenen JE, Russell RC, Meyers WC, Liguory C, Nickl N. Endoscopic sphincterotomy complications and their management: an attempt at consensus. Gastrointest Endosc. 1991 May-Jun;37(3):383-93. doi: 10.1016/s0016-5107(91)70740-2.
Results Reference
background
PubMed Identifier
11437039
Citation
Mortensen MB, Pless T, Durup J, Ainsworth AP, Plagborg GJ, Hovendal C. Clinical impact of endoscopic ultrasound-guided fine needle aspiration biopsy in patients with upper gastrointestinal tract malignancies. A prospective study. Endoscopy. 2001 Jun;33(6):478-83. doi: 10.1055/s-2001-14966.
Results Reference
background

Learn more about this trial

Evaluation of Multiple Needle Use in EUS-FNA for Pancreatic Cancer

We'll reach out to this number within 24 hrs