search
Back to results

Fluoro-L-Thymidine Positron Emission Tomography (FLT PET) vs. Adv. Magnetic Resonance (MR) Techniques in Recurrent Glioma

Primary Purpose

Brain Tumor

Status
Withdrawn
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
PET Scan
3'-Deoxy-3'-18f-Fluorothymidine
Sponsored by
M.D. Anderson Cancer Center
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional diagnostic trial for Brain Tumor focused on measuring Brain tumor, 3'-Deoxy-3'-18f-Fluorothymidine, Fluoro-L-Thymidine Positron Emission Tomography, FLT PET, Magnetic resonance imaging, MRI

Eligibility Criteria

18 Years - undefined (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  1. Patient is >/= 18 years old, agrees to participate in the clinical study and to complete all required visits and evaluations. The pediatric population has a different disease profile from the glioma patients we hope to recruit. To reduce heterogeneity in the patient population we will not consider patients younger than 18 for this study.
  2. Patient is a candidate for cerebral tumor resection due to an enhancing brain lesion, with history of previous pathologically proven primary brain tumor (WHO grade II-IV diffuse glioma)
  3. Patient had diffuse glioma (WHO grade 2 - 4) and as part of their treatment received radiation therapy and Temozolomide (a first-line chemotherapeutic agent).
  4. Patient will have subsequently developed an enhancing brain mass greater than 1cm in diameter, at least 6 months after finishing radiation therapy (to differentiate from the more acute treatment related effect of "pseudo-progression").
  5. As the predominate means of determining TRN versus recurrent glial tumor at MD Anderson, a brain tumor/ necrosis protocol is ordered as clinically indicated.
  6. Patient's clinician based on the clinical and MR information wants to proceed with biopsy or surgical resection within 30 days from when the brain tumor MR protocol was performed. The patient meets with the neurosurgeon and agrees to surgical biopsy or resection.
  7. Patient is able to understand and give consent to participation in the study
  8. Patient has received as part of their care the Brain Tumor Imaging protocol.
  9. Patient agrees to undergo, prior to the procedure, FLT PET at CABI

Exclusion Criteria:

  1. The patient is found to have unfavorable anatomy to indicate that stereotactic biopsy/ resection could not be safely performed
  2. Claustrophobia that does not readily respond to oral medication
  3. Allergy to Fluoro-L-Thymidine
  4. Pregnant or lactating (Based on self-reported and clinical care testing with physicians before study participation)

Sites / Locations

    Arms of the Study

    Arm 1

    Arm Type

    Experimental

    Arm Label

    FLT PET Scan + 3'-Deoxy-3'-18f-Fluorothymidine

    Arm Description

    After a magnetic resonance imaging (MRI) scan of brain performed, an FLT PET scan using 3'-Deoxy-3'-18f-Fluorothymidine solution performed. After solution is injected into a vein, the PET scanner takes pictures of the radioactive solution as it moves through the body and collects at various sites in the body. The entire procedure should last about 60-70 minutes.

    Outcomes

    Primary Outcome Measures

    Performance of Fluoro-L-Thymidine Positron Emission Tomography (FLT PET) and Perfusion Magnetic Resonance Imaging (MRI) in the Diagnosis of Recurrent High-Grade Glial Tumor
    Performance (sensitivity, specificity, negative/ positive predictive values) for MR perfusion and FLT PET made using prior reported values (PEI > 20% 10 and normalized uptake >1.3 17, respectively). Particular attention placed on the location for ROI's and pathology sampling in large heterogenous lesions. Additional, exploratory analysis performed to determine post-hoc optimal cut-off values for classifying glioma vs. necrosis. Logistic regression used to fit a model using a combination of a perfusion values, spectroscopy values, diffusion values, and values from FLT PET.

    Secondary Outcome Measures

    Full Information

    First Posted
    September 2, 2014
    Last Updated
    February 25, 2016
    Sponsor
    M.D. Anderson Cancer Center
    Collaborators
    GE Healthcare
    search

    1. Study Identification

    Unique Protocol Identification Number
    NCT02241668
    Brief Title
    Fluoro-L-Thymidine Positron Emission Tomography (FLT PET) vs. Adv. Magnetic Resonance (MR) Techniques in Recurrent Glioma
    Official Title
    Pilot Study to Assess Accuracy of Time-resolved FLT PET and MR Techniques in Determining Treatment-related Necrosis From Recurrent Glioma
    Study Type
    Interventional

    2. Study Status

    Record Verification Date
    February 2016
    Overall Recruitment Status
    Withdrawn
    Why Stopped
    Withdrawn due to other initiatives
    Study Start Date
    June 2015 (undefined)
    Primary Completion Date
    June 2015 (Actual)
    Study Completion Date
    undefined (undefined)

    3. Sponsor/Collaborators

    Responsible Party, by Official Title
    Sponsor
    Name of the Sponsor
    M.D. Anderson Cancer Center
    Collaborators
    GE Healthcare

    4. Oversight

    Data Monitoring Committee
    No

    5. Study Description

    Brief Summary
    The goal of this clinical research study is to learn if using a new imaging solution, 3'-Deoxy-3'-18f-Fluorothymidine, in a positron emission tomography (PET) scan can help doctors determine if your brain lesion is from the tumor returning or the effects of previous treatments. The results of this imaging scan (called an FLT PET scan) will be compared to the results of a Magnetic Resonance Imaging scan, which you have already had or are scheduled to have outside of this study.
    Detailed Description
    FLT PET Scan: If you are found to be eligible to take part in this study, you will have an FLT PET scan. An FLT PET scan uses the 3'-Deoxy-3'-18f-Fluorothymidine solution, which contains a small amount of radioactive material. The radioactive nature of the solution allows the scanner to "see" it in certain places in your body. You will receive the solution by vein through a catheter. A central venous catheter is a sterile flexible tube that will be placed into a large vein while you are under local anesthesia. Your doctor will explain this procedure to you in more detail, and you will be required to sign a separate consent form. After the injection, you will need to rest quietly until it is time for the scan. The amount of rest time may vary, but be prepared to wait for about 60 minutes. During the scan, you will lie flat on your back on a table. After the solution is injected into a vein, the PET scanner takes pictures of the radioactive solution as it moves through the body and collects at various sites in the body. By watching how the solution travels through the body and studying where the solution collects, researchers may be able to learn where the disease is in your body. The entire procedure should last about 60-70 minutes. You must not eat or drink anything except water for at least 6 hours before the FLT PET scan. About 2 minutes after the FLT solution is injected, blood (about 10 teaspoons) will be drawn from the catheter. This blood will be drawn to measure how much FLT is in your body and may help the study staff understand the images better. Length of Study: After the FLT PET scan is complete, your active participation on this study will be over. Follow-Up Medical Record Review: About 30 days after the FLT PET scan, you will be contacted by phone by the study staff to check if you are having any side effects. The phone call should last about 15 minutes. Your medical records will continue to be reviewed for up to an additional 5 years to learn how you are doing, what other treatments you may have had and how they worked, if you had any new brain problems, or if the tumor came back. This is an investigational study. The 3'-Deoxy-3'-18f-Fluorothymidine solution is not FDA approved or commercially available. At this time, 3'-Deoxy-3'-18f-Fluorothymidine solution is only being used in research. Up to 20 patients will take part in this study. All will be enrolled at MD Anderson.

    6. Conditions and Keywords

    Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
    Brain Tumor
    Keywords
    Brain tumor, 3'-Deoxy-3'-18f-Fluorothymidine, Fluoro-L-Thymidine Positron Emission Tomography, FLT PET, Magnetic resonance imaging, MRI

    7. Study Design

    Primary Purpose
    Diagnostic
    Study Phase
    Not Applicable
    Interventional Study Model
    Single Group Assignment
    Masking
    None (Open Label)
    Allocation
    N/A
    Enrollment
    0 (Actual)

    8. Arms, Groups, and Interventions

    Arm Title
    FLT PET Scan + 3'-Deoxy-3'-18f-Fluorothymidine
    Arm Type
    Experimental
    Arm Description
    After a magnetic resonance imaging (MRI) scan of brain performed, an FLT PET scan using 3'-Deoxy-3'-18f-Fluorothymidine solution performed. After solution is injected into a vein, the PET scanner takes pictures of the radioactive solution as it moves through the body and collects at various sites in the body. The entire procedure should last about 60-70 minutes.
    Intervention Type
    Procedure
    Intervention Name(s)
    PET Scan
    Other Intervention Name(s)
    Positron Emission Tomography
    Intervention Description
    FLT Pet Scan performed about 60 minutes after 3'-Deoxy-3'-18f-Fluorothymidine solution injected.
    Intervention Type
    Drug
    Intervention Name(s)
    3'-Deoxy-3'-18f-Fluorothymidine
    Intervention Description
    3'-Deoxy-3'-18f-Fluorothymidine solution injected through a central venous catheter after MRI scan. After solution injected into a vein, PET scanner takes pictures of the radioactive solution as it moves through the body and collects at various sites in the body. Entire procedure should last about 60-70 minutes.
    Primary Outcome Measure Information:
    Title
    Performance of Fluoro-L-Thymidine Positron Emission Tomography (FLT PET) and Perfusion Magnetic Resonance Imaging (MRI) in the Diagnosis of Recurrent High-Grade Glial Tumor
    Description
    Performance (sensitivity, specificity, negative/ positive predictive values) for MR perfusion and FLT PET made using prior reported values (PEI > 20% 10 and normalized uptake >1.3 17, respectively). Particular attention placed on the location for ROI's and pathology sampling in large heterogenous lesions. Additional, exploratory analysis performed to determine post-hoc optimal cut-off values for classifying glioma vs. necrosis. Logistic regression used to fit a model using a combination of a perfusion values, spectroscopy values, diffusion values, and values from FLT PET.
    Time Frame
    1 day

    10. Eligibility

    Sex
    All
    Minimum Age & Unit of Time
    18 Years
    Accepts Healthy Volunteers
    No
    Eligibility Criteria
    Inclusion Criteria: Patient is >/= 18 years old, agrees to participate in the clinical study and to complete all required visits and evaluations. The pediatric population has a different disease profile from the glioma patients we hope to recruit. To reduce heterogeneity in the patient population we will not consider patients younger than 18 for this study. Patient is a candidate for cerebral tumor resection due to an enhancing brain lesion, with history of previous pathologically proven primary brain tumor (WHO grade II-IV diffuse glioma) Patient had diffuse glioma (WHO grade 2 - 4) and as part of their treatment received radiation therapy and Temozolomide (a first-line chemotherapeutic agent). Patient will have subsequently developed an enhancing brain mass greater than 1cm in diameter, at least 6 months after finishing radiation therapy (to differentiate from the more acute treatment related effect of "pseudo-progression"). As the predominate means of determining TRN versus recurrent glial tumor at MD Anderson, a brain tumor/ necrosis protocol is ordered as clinically indicated. Patient's clinician based on the clinical and MR information wants to proceed with biopsy or surgical resection within 30 days from when the brain tumor MR protocol was performed. The patient meets with the neurosurgeon and agrees to surgical biopsy or resection. Patient is able to understand and give consent to participation in the study Patient has received as part of their care the Brain Tumor Imaging protocol. Patient agrees to undergo, prior to the procedure, FLT PET at CABI Exclusion Criteria: The patient is found to have unfavorable anatomy to indicate that stereotactic biopsy/ resection could not be safely performed Claustrophobia that does not readily respond to oral medication Allergy to Fluoro-L-Thymidine Pregnant or lactating (Based on self-reported and clinical care testing with physicians before study participation)
    Overall Study Officials:
    First Name & Middle Initial & Last Name & Degree
    Eric Rohren, MD, PHD
    Organizational Affiliation
    M.D. Anderson Cancer Center
    Official's Role
    Principal Investigator

    12. IPD Sharing Statement

    Links:
    URL
    http://www.mdanderson.org
    Description
    University of Texas MD Anderson Cancer Center Website

    Learn more about this trial

    Fluoro-L-Thymidine Positron Emission Tomography (FLT PET) vs. Adv. Magnetic Resonance (MR) Techniques in Recurrent Glioma

    We'll reach out to this number within 24 hrs