search
Back to results

Fully Disposable Patient-Specific Instrumentation (MyKnee)

Primary Purpose

Osteoarthritis,Knee

Status
Completed
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
GMK Medacta Total Knee arthroplasty
Sponsored by
Cochin Hospital
About
Eligibility
Locations
Arms
Outcomes
Full info

About this trial

This is an interventional treatment trial for Osteoarthritis,Knee

Eligibility Criteria

18 Years - 85 Years (Adult, Older Adult)All SexesDoes not accept healthy volunteers

Inclusion Criteria:

  • patients aged between 18 and 85 years
  • able to understand information
  • affiliated to social security

Exclusion Criteria:

  • active or suspected sepsis
  • tumor around the knee
  • previous partial or total knee replacement
  • extra-articular deformation requiring osteotomy around the knee in conjunction with TKA
  • social situation that could impair follow-up

Sites / Locations

    Arms of the Study

    Arm 1

    Arm 2

    Arm 3

    Arm Type

    Active Comparator

    Experimental

    Experimental

    Arm Label

    CI

    PSCG

    PSCG-D

    Arm Description

    TKA using conventional instrumentation (CI)

    TKA performed using Patient specific cutting guides (PSCG)

    TKA performed using fully disposable Patient specific cutting guides (PSCG-D)

    Outcomes

    Primary Outcome Measures

    HKA angle
    Lower limb mechanical axis was measured on a bipodal standing leg-length anteroposterior radiograph with the patella oriented straight made three months postoperatively, using Roman software version 1.70 (Oswestry, United Kingdom). Postoperative lower limb mechanical axis was calculated from the Hip-Knee-Ankle (HKA) angle between the femoral and tibial mechanical axes, respectively. An HKA angle greater than 180° was indicative of valgus, whereas values lower than 180° indicated varus.

    Secondary Outcome Measures

    % outliers
    % of patients with an HKA angle outside 180°+/- 3°
    Knee Society Score
    Validated pain and function score following TKA
    Oxford Knee Score
    Patients self assessment of knee function

    Full Information

    First Posted
    September 26, 2016
    Last Updated
    November 15, 2016
    Sponsor
    Cochin Hospital
    search

    1. Study Identification

    Unique Protocol Identification Number
    NCT02966613
    Brief Title
    Fully Disposable Patient-Specific Instrumentation
    Acronym
    MyKnee
    Official Title
    Primary TKA Using a Fully Disposable Patient-Specific Instrumentation: A Multicenter Controlled Study
    Study Type
    Interventional

    2. Study Status

    Record Verification Date
    November 2016
    Overall Recruitment Status
    Completed
    Study Start Date
    September 2013 (undefined)
    Primary Completion Date
    December 2015 (Actual)
    Study Completion Date
    September 2016 (Actual)

    3. Sponsor/Collaborators

    Responsible Party, by Official Title
    Principal Investigator
    Name of the Sponsor
    Cochin Hospital

    4. Oversight

    Data Monitoring Committee
    No

    5. Study Description

    Brief Summary
    To evaluate the lower limb alignment following total knee arthroplasty (TKA) performed with fully disposable patient-specific instrumentation versus conventional, versus patient specific instrumentation.
    Detailed Description
    The investigators performed a controlled multicenter trial comparing the clinical and radiologic results and resources consumption of primary TKA using patient-specific cutting guides (PSCG) versus conventional instrumentation (CI), and compared the results to those obtained with a fully disposable patient-specific instrumentation (PSCG-D).

    6. Conditions and Keywords

    Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
    Osteoarthritis,Knee

    7. Study Design

    Primary Purpose
    Treatment
    Study Phase
    Not Applicable
    Interventional Study Model
    Parallel Assignment
    Masking
    Outcomes Assessor
    Allocation
    Randomized
    Enrollment
    210 (Actual)

    8. Arms, Groups, and Interventions

    Arm Title
    CI
    Arm Type
    Active Comparator
    Arm Description
    TKA using conventional instrumentation (CI)
    Arm Title
    PSCG
    Arm Type
    Experimental
    Arm Description
    TKA performed using Patient specific cutting guides (PSCG)
    Arm Title
    PSCG-D
    Arm Type
    Experimental
    Arm Description
    TKA performed using fully disposable Patient specific cutting guides (PSCG-D)
    Intervention Type
    Device
    Intervention Name(s)
    GMK Medacta Total Knee arthroplasty
    Intervention Description
    Total Knee arthroplasty
    Primary Outcome Measure Information:
    Title
    HKA angle
    Description
    Lower limb mechanical axis was measured on a bipodal standing leg-length anteroposterior radiograph with the patella oriented straight made three months postoperatively, using Roman software version 1.70 (Oswestry, United Kingdom). Postoperative lower limb mechanical axis was calculated from the Hip-Knee-Ankle (HKA) angle between the femoral and tibial mechanical axes, respectively. An HKA angle greater than 180° was indicative of valgus, whereas values lower than 180° indicated varus.
    Time Frame
    3 months
    Secondary Outcome Measure Information:
    Title
    % outliers
    Description
    % of patients with an HKA angle outside 180°+/- 3°
    Time Frame
    3 months
    Title
    Knee Society Score
    Description
    Validated pain and function score following TKA
    Time Frame
    3 months
    Title
    Oxford Knee Score
    Description
    Patients self assessment of knee function
    Time Frame
    3 months

    10. Eligibility

    Sex
    All
    Minimum Age & Unit of Time
    18 Years
    Maximum Age & Unit of Time
    85 Years
    Accepts Healthy Volunteers
    No
    Eligibility Criteria
    Inclusion Criteria: patients aged between 18 and 85 years able to understand information affiliated to social security Exclusion Criteria: active or suspected sepsis tumor around the knee previous partial or total knee replacement extra-articular deformation requiring osteotomy around the knee in conjunction with TKA social situation that could impair follow-up

    12. IPD Sharing Statement

    Citations:
    PubMed Identifier
    29576488
    Citation
    Abane L, Zaoui A, Anract P, Lefevre N, Herman S, Hamadouche M. Can a Single-Use and Patient-Specific Instrumentation Be Reliably Used in Primary Total Knee Arthroplasty? A Multicenter Controlled Study. J Arthroplasty. 2018 Jul;33(7):2111-2118. doi: 10.1016/j.arth.2018.02.038. Epub 2018 Feb 17.
    Results Reference
    derived

    Learn more about this trial

    Fully Disposable Patient-Specific Instrumentation

    We'll reach out to this number within 24 hrs