Interest of Pre-operative Use of 3D Printing for Endovascular Treatment of Unruptured Intracranial Aneurysms With Intrasaccular Flow Disruptor (ILIAD)
Primary Purpose
Intracranial Aneurysm
Status
Not yet recruiting
Phase
Not Applicable
Locations
Study Type
Interventional
Intervention
3D anatomical model of aneurysm
Sponsored by
About this trial
This is an interventional other trial for Intracranial Aneurysm
Eligibility Criteria
Inclusion Criteria: Intracranial aneurysm, suitable for a treatment by Woven Endobridge (WEB) device after multidisciplinary team decision Consent form signed The patient benefits from health insurance Exclusion Criteria: Legal incapacity Women at risk of pregnancy
Sites / Locations
Arms of the Study
Arm 1
Arm 2
Arm Type
Experimental
No Intervention
Arm Label
With 3D anatomical model
Without 3D anatomical model
Arm Description
Surgery prepared using 3D anatomical model of the aneurysm
Surgery prepared without 3D anatomical model of the aneurysm (routine care)
Outcomes
Primary Outcome Measures
Proportion of patients with successful procedure
Proportion of patients for which flow disruption succeeded at first intent, without any change of size required for WEB disruptor
Secondary Outcome Measures
Full Information
NCT ID
NCT05665309
First Posted
December 16, 2022
Last Updated
September 26, 2023
Sponsor
Centre Hospitalier Universitaire de Besancon
1. Study Identification
Unique Protocol Identification Number
NCT05665309
Brief Title
Interest of Pre-operative Use of 3D Printing for Endovascular Treatment of Unruptured Intracranial Aneurysms With Intrasaccular Flow Disruptor
Acronym
ILIAD
Official Title
Interest of Pre-operative Use of 3D Printing for Endovascular Treatment of Unruptured Intracranial Aneurysms With Intrasaccular Flow Disruptor
Study Type
Interventional
2. Study Status
Record Verification Date
September 2023
Overall Recruitment Status
Not yet recruiting
Study Start Date
September 2023 (Anticipated)
Primary Completion Date
September 2025 (Anticipated)
Study Completion Date
December 2025 (Anticipated)
3. Sponsor/Collaborators
Responsible Party, by Official Title
Sponsor
Name of the Sponsor
Centre Hospitalier Universitaire de Besancon
4. Oversight
Studies a U.S. FDA-regulated Drug Product
No
Studies a U.S. FDA-regulated Device Product
No
Data Monitoring Committee
No
5. Study Description
Brief Summary
This is a preliminary randomised controlled trial comparing the use of pre-operative 3D models to select an intrasaccular flow disruptor for endovascular aneurysm cure.
Detailed Description
Patients will be randomised 3:1 either in the intervention or control group. Intervention consists of using the pre-operative Digital Subtraction Angiography (DSA) to create a 3D plastic model. This model is used to test different sizes of device. At the end of this pre-operative test a single device is recommended for the real procedure. The control group will use the current method for size selection (measurement of mean width and minimum height) on DSA.
6. Conditions and Keywords
Primary Disease or Condition Being Studied in the Trial, or the Focus of the Study
Intracranial Aneurysm
7. Study Design
Primary Purpose
Other
Study Phase
Not Applicable
Interventional Study Model
Parallel Assignment
Masking
None (Open Label)
Allocation
Randomized
Enrollment
60 (Anticipated)
8. Arms, Groups, and Interventions
Arm Title
With 3D anatomical model
Arm Type
Experimental
Arm Description
Surgery prepared using 3D anatomical model of the aneurysm
Arm Title
Without 3D anatomical model
Arm Type
No Intervention
Arm Description
Surgery prepared without 3D anatomical model of the aneurysm (routine care)
Intervention Type
Procedure
Intervention Name(s)
3D anatomical model of aneurysm
Intervention Description
Surgery prepared with 3D anatomical model of aneurysm
Primary Outcome Measure Information:
Title
Proportion of patients with successful procedure
Description
Proportion of patients for which flow disruption succeeded at first intent, without any change of size required for WEB disruptor
Time Frame
Day 0
10. Eligibility
Sex
All
Minimum Age & Unit of Time
18 Years
Maximum Age & Unit of Time
80 Years
Accepts Healthy Volunteers
No
Eligibility Criteria
Inclusion Criteria:
Intracranial aneurysm, suitable for a treatment by Woven Endobridge (WEB) device after multidisciplinary team decision
Consent form signed
The patient benefits from health insurance
Exclusion Criteria:
Legal incapacity
Women at risk of pregnancy
Central Contact Person:
First Name & Middle Initial & Last Name or Official Title & Degree
Guillaume CHARBONNIER, MD
Phone
+33381668502
Email
g1charbonnier@chu-besancon.fr
Overall Study Officials:
First Name & Middle Initial & Last Name & Degree
Guillaume CHARBONNIER, MD
Organizational Affiliation
CHU de Besançon
Official's Role
Principal Investigator
12. IPD Sharing Statement
Learn more about this trial
Interest of Pre-operative Use of 3D Printing for Endovascular Treatment of Unruptured Intracranial Aneurysms With Intrasaccular Flow Disruptor
We'll reach out to this number within 24 hrs