OCT Based Edge and In-stent Vascular Response After Cordimax Stent in patIents With NSTE-ACS
Angina, Unstable, Non-ST-Segment Elevation Myocardial Infarction
About this trial
This is an interventional supportive care trial for Angina, Unstable
Eligibility Criteria
Inclusion Criteria:
- age ≥18 and ≤ 75 years
- Non-ST-segment elevation MI
- Patient willing to comply with specified follow-up
5.Patient or legally authorized representative has been informed of the nature of the study, agrees to its provisions and has been provided written informed consent 6.Single or two de novo or non-stented restenotic lesion in a native coronary artery 7. Target lesion to be covered by a single stent of max 30 mm . Reference vessel diameter ≥2.25 to ≤ 4.0 mm by visual estimate 8. The vessel diameter should be measured after pre-dilation procedure and after intra-coronary nitroglycerin if spasm is suspected 9. Target lesion ≥70% stenosed by visual estimate
Exclusion Criteria:
- Pregnant or nursing patients and those who plan pregnancy in the period up to 1 year following index procedure. Female patients of childbearing potential must have a negative pregnancy test done within 7 days prior to the index procedure per site standard test
- Impaired renal function or on dialysis
- Platelet count <100,000 cells/mm3 or >700,000 cells/mm3 or a WBC<3,000 cells/mm3
- Patient has a history of bleeding diathesis or coagulopathy or patients in whom anti-platelet and/or anticoagulant therapy is contraindicated
- Patient requires low molecular weight heparin (LMWH) treatment postprocedure or has received a dose of LMWH ≤8 hours prior to index procedure
- Patient has received any organ transplant or is on a waiting list for any organ transplant;
- Patient has other medical illness or known history of substance abuse that may cause non-compliance with the protocol, confound the data interpretation or is associated with a limited life expectancy (<1 year)
- Patient has a known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, clopidogrel/ticlopidine, prasugrel, stainless steel alloy, sirolimus and/or contrast sensitivity that cannot be adequately pre-medicated
- Patient has previously received murine therapeutic antibodies and exhibited sensitization through the production of Human Anti-Murine Antibodies
- Patient presents with cardiogenic shock
- Patient has extensive peripheral vascular disease that precludes safe 6 French sheath insertion;
- Any significant medical condition which in the Investigator's opinion may interfere with the patient's optimal participation in the study
- Currently participating in another investigational drug or device study or patient in inclusion in another investigational drug or device study during follow-up
- Calcified target lesion(s) which cannot be successfully predilated
- Target lesion has excessive tortuosity unsuitable for stent delivery and deployment;
Sites / Locations
Arms of the Study
Arm 1
Arm 2
Active Comparator
Active Comparator
OCT at 3 months
OCT at 6months
OCT at 3 months and 12 OCT at 3 months
OCT at 6 months and 12 OCT at 3 months